Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.3 LAccepted-AOC | 1 | Accepted-AOC Award | |
| 2 | Rejected-Technical N A | - | Rejected-Technical Reject |
Tender Value
Refer Docs
Closing Date
2 Feb 2022, 5:00 pmClosed
Executive Engineer Maint.Div UJS
Office Of Executive Engineer, Maintenance Division, Uttrakhand Jal Sansthan Lane No-1, Tarun Vihar, Mothrowala Road, Dehradun-248001
Construction of Tipperpur Water Supply Scheme I/C Installation , Testing and Commisioning of Rising Main and Distribution System etc Complete
2022_UKJS_41369_9
3806/E-Tender Notice/2021-22 dt 24.12.2021
Open Tender
Civil Works - Water Works
Item Rate
365 days
Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,720
Executive Engineer Maint. Div UJS
Exempted
Dehradun
19 Jul 2023
4 Jan 2022
3 Feb 2022
4 Jan 2022
2 Feb 2022
10 Jan 2022
7 Jan 2022
Construction of Tipperpur Water Supply Scheme Installation, testing & commissioning of Iising Main Distribution System etc. complete. under Jal Jeevan Mission Program.
Pump and Related Electrical Items- Supply of Energy Efficient Submersible Pumpsets of various duty parameters, Make KSB- Pump of 800 LPM dischage at 180 m head with 60 HP electric motor (TW-1 to OHT-1)
Supply, Installation, Testing and Commissioning of Lorag Gateway senser system suitable for providing automatically data of Rasidual Chlorine ,Flow Meter and Pressure incl all supply of materil testing of senser at site and painting entire insttlalation etc. as per unit estimate complete.
Civil Work- Supply of all Materials, Labours, T&P etc. and repairing of Existing Pump House. (@ 20% of construction of New Pump House)
Provide all Materials, Labour, T & P etc and Construct Boundary Wall 2.00 m Height & Iron Grill Over it, All Round the Tube Well & O.H.T Campus to prevent the approach of unauthorised souls.30 % of construction of New Pump House
Provide all Materials, Labour, T & P etc and construct 3.60 m Wide Entrance Gate with Gate Pillars for controlling approach to the area.
Supplying and Installation, testing and commissioning of Non Return Valves Including Carting the same upto the site of workas per engineering norms anywhere in uttarakhand. -D.I. Non Return Valve -Pressure PN 1.6- 150 mm dia
Installation, testing and commissioning of Non Return Valves as per engineering norms anywhere in uttarakhand. - D.I. Non Return Valve - Pressure PN 1.6- 150 mm dia
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For different types of valves.
Supply of all materials labour, T&P etc and construction of RCC O.H.T. of following capacities (in Kilolitres) and 12m staging with 1.00m wide R.C.C. stair case from G.L. to balcony and from balcony to top dome 1M x 1M R.C.C., landing at suitable locations and railed with 3 rows of 20mm dia G.I. (M) pipe on 65x65x5mm angle iron posts fixed with ladder, from top to the floor inside of tank, M.S. M.H. cover with locking arrangement, lightining conductor as per electricity rules, water level indicator, supply and fixing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60m wide apron, painting on tank body vertical pipes, ladder, M.s. M.h. cover, ventillator column etc, complete with approved water proofing (apex)/ enamel paint, testing, filling water for testing purpose etc, including supply of vertical pipes and specials, assuming bearing capacity as 10MT/M² staging 12.00 metre- Repairig of 250KL OHT Staging 18.0M @ 10% of New cost of OHT
Dismantling old 100KL OHT Staging 13.0M
Interconntion of Over Flow Distribution pipe line including cost of all metrials, labour, shuttering, scaffolding T&P complete.
Thrust Block (Details attached as separate estimate)
4.0 Distribution Network & Related Components- Dismantling of flexible pavements and disposal ofdismantled materialsupto alead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202 (Considering 30%)
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately (Considering 30%)
Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383,maximum size ofcoarse aggregate notexceeding 25 mm,mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
Excavation in Pipe Line Trenches Excavation in ordinary soil (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling waterring and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth (75% of Total Quantity)
Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches.(25% of Total Quantity)
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. G.I. PIPE CONFORMING TO IS : 1239(PART-1) Medium Duty (Class 'B')- 15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
HDPE pipe for water supply conforiming to IS:4984-1995 Proving of all materials, carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full lengths of HDPE pipes, completion of work with testing of pipe line including supply of Jointing materials & specials.- PE-100, Normal Pressure(PN)-6 in 6 kg/cm2- 63 mm dia pipe
75 mm dia pipe
90 mm dia pipe
110 mm dia pipe
D.I. pipe conforiming to IS:8329/2000 Proving of all materials, carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full length S&S Centrifugally Cast (Spun) Ductile Iron Pipes by overlap fusion joint including supply of 'EPDM' rubber gaskets conforming to IS:5382-1985 with testing of pipe line complete. -D.I. Pipe S&S K-7- 150 mm dia pipe
Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS: 9523-2000 (5% of DI Pipe weight)
Supplying of DI Valves Including Carting the same upto the site of work as per engineering norms (with cap) complete with bolts, nuts, rubber insertions etc. anywhere in uttarakhand. -D.I. Sluice/ Gate Valve -Pressure PN 1.0- 50 mm dia
80 mm dia
Installation, testing and commissioning of DI Valves as per engineering norms anywhere in uttarakhand. -D.I. Sluice/ Gate Valve- 50 mm dia
80 mm dia
Supplying and Fixing of Fire Hydrant Valve IS 5290 (Flanged) Including carting the same upto site of work and fixing the same and water supply line Including the cost of valves,specials,labour and T&P Complete in all respect.- 80 mm diameter
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For different types of valves.
Supply,Installation,Testing and Commissioning of Full Bore Electromagnetic Flow Meter for Lines of followoing Sizes Comprising of Flow Tube Sensor with Transmitter cum Display unit and facility to provide data communication signal over Modbus 485 Port Pulse output and 4-20mA Signal output with Flanges, Clamps etc -At Outlet of OHT- 250 mm
Supply of all labour, material required for restoring of existing house connection which might be damage during excavation and also shifting all existing connection to new water supply system from existing water supply system complete as per unit estimate and directed by Engineer in-charge. 15 mm size water connections.(Considering 20% of 2020 Households)
Providing and making house service connections from water supply distribution GI pipe line upto water meter chamber inside the property using GI pipe including supply and fixing of electrofussion saddle ,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
Making connection with the existing M.S. Galvanised mains of upto 25mm nominal dia, including cutting and threading of pipe, bailing out water, fixing, if required, specials and testing etc. complete, but excluding cost of insertion pipes and specials besides boring out (and also subsequent back fill) existing main.- 50mm-80 mm
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube osts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m.
Pipe Testing G.I. HDPE and DI and testing of all parameter ( physical and chemical perameretrs )- Pipe Testing GI and HDPE testing of all parameter ( physical and chemical perameretrs) dia ,Thinkness ,carbon manganesh ,sulhher phosphoras zinc, tensile strength ,Elongantion,Lerk proof and Hadrostatic etc complet
Pipe Testing of DI ( physical and chemical perameretrs )
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .