Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 701 7TH FLOOR LE MERIDIEN COMMERCIAL TOWER RAISINA ROAD NEW DELHI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
5 Aug 2021, 10:00 amClosed
ASD
NAVAL DOCKYARD VISAKHAPATNAM
ERDD OF IN ASSET
2021_NAVY_460348_1
COM/0993/IN ASSET/ERDD O/L-21/A
Open Tender
Marine Services
Turn-key
210 days
NAVAL DOCKYARD VISAKHAPATNAM
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
COY CONFERENCE ROOM
1 Oct 2021
16 Jul 2021
6 Aug 2021
16 Jul 2021
5 Aug 2021
23 Jul 2021
16 Jul 2021 - 5 Aug 2021
22 Jul 2021
SOW- IN ASSET -01 001 Docking- Vessel to be docked in both versions. Note 1:- Firms not to quote view docking, undocking and dock blocks preparation will be done by Navy and the job is required to be carried out in Navy Premises Last Undock -Sep 18
002 Hull Cleaning Under Water Free Flood and Boot Top Area HP jet clean entire under water area including free flood area and boot top area (with a pressure not exceeding 3000 PSI) including ship side and remove the mud / marine growth/barnacles and prepare for survey.
002 Hull Cleaning Above Water Area (a) Clean the entire above water area with HP Jet washing (with a pressure not exceeding 3000 PSI) I.A.W. No 01/15 and present for survey
002 Hull Cleaning Weather deck (b) Clean the entire weather deck including deck fittings with HP Jet washing (not exceeding 3000 PSI) I.A.W. No 01/15 and present for survey
002 Hull Cleaning Tanks (c) Manually clean internal tanks i.a.w. No 01/15 and present for survey.
003 Hull survey External and Internal Hull survey. Hull survey. Carry out visual and hammer survey/UTG survey in accordance with NO 19/06 of under water hull, boot top, above water hull, weather decks and all internal tanks etc, all stiffeners and deck fittings including lifting hooks/eyes. Approx area: 2690 Sqm
004 UTG Survey Quote for UTG survey points at u/w hull ,above water and weater deck and internal tanks .
005 Steel Renewals Quote for steel renewal at various locations as per survey report. Note 1:- Quoted repair cost shall include cost of both sides blasted and primed Grade `A’ quality ship building steel for shell and IS 2062 Grade `B’ quality steel for non structural works, renewal of all obstructions in way of steel renewals including minor fittings with their foundations, etc., as indicated by survey team / RMT, proving of the weld runs by non-destructive tests and by hose test on completion of welding, pressure testing and proving of tanks where steel renewal undertaken etc.
006 Build ups Carry out build ups as indicated by the Hull survey team/ Surveyor (a) Approx size 25x25 mm-250 Nos
006 Build ups Carry out build ups as indicated by the Hull survey team/ Surveyor (b) Approx size 50x50 mm - 150 Nos
007 Fairing Carryout fairing of deformed structures as indicated by Hull Survey Team/ Surveyor
008 Re-welding run Carry out re-welding runs on weld seams as indicated by Hull survey team/ QC/ RMT.
009 Draught Marks Draught marks corroded/eaten away, to be renewed and painted. Both Roman and Numeric.
010 Sacrificial Anodes Renew Sacrificial anodes (MK I) those consumed more than 50% Note:- Anodes Navy/COY supply.
011 Surface preparation with Grit Blasting Under Water area including free flood area and Boot top area Spot blasting to SA 2.5 on paint damaged areas/ renewed plate areas as per the paint OEM rep recommendation for paint application.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Primer - penguard primer - 50 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Anti Corrosive - Jotacote Universal (Aluminium) - 150 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Anti Corrosive - Jotacote Universal (grey) - 150 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat: Tie Coat: Safeguard ES - 125 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (e) 5th Coat: A/F:Sea Quantum Pro U and Spectrum 150 microns (Light Red/Dark Red) Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (f) 6th Coat: A/F: Sea Quantum Pro U and Spectrum 150 microns (Light Red/Dark Red) Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (g) 7th Coat: A/F: Seaquantum Ultra( Black) - 2 x 150 microns
013 Surface Preparation Above Water Area Carry out surface preparation w on above water area to SA2.5 standard under the suprvision of paint OEM.
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Penguard primer - 50 microns DFT
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Jotamastic(Grey/ Red Brown) - 125 microns DFT
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Jotamastic(Grey/ Red Brown) - 125 microns DFT
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat: Hard Top XP Grey - 60 microns DFT
015 Surface Preparation Weather Decks and Fittings Carry out Surface pre[partion to WJ 2 standard as per survey report of Paint OEM for paint application for entire weather deck.
016 Painting - JOTUN Scheme Weather Decks and Fittings Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Penguard Primer -50 microns DFT
016 Painting - JOTUN Scheme Weather Decks and Fittings Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Jotamastic 87 of 200 microns
016 Painting - JOTUN Scheme Weather Decks and Fittings Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Jota Armour Dark grey of 800 microns
017 Surface Preparation Internal Tanks Carry out Grit blasting to SA 2.5 standard at paint defective area/ as survey report of Paint OEM for paint application.
018 Painting - JOTUN Scheme Paint all internal tanks with following paint scheme Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Penguard Primer -50 microns DFT
018 Painting - JOTUN Scheme Paint all internal tanks with following paint scheme Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Anticorrosive Balloxy (HB light) - 150 microns
018 Painting - JOTUN Scheme Paint all internal tanks with following paint scheme Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Anticorrosive Balloxy (HB light) - 150 microns
019 Deck Fitting Fair lead (MS cleats) including base plate corroded/perished, to be renewed as per survey report (a) Size of eye plate- 230x550x20 mm thick plate,
019 Deck Fitting Twin bollards on weather deck including base plate corroded/perished, to be renewed as per survey report (b) Twin Bollard size dia- 400x800x20 mm height
019 Deck Fitting Twin bollards on weather deck including base plate corroded/perished, to be repaired as per survey report (c) Twin Bollard size dia- 400x800x20 mm height
020 Manhole cover (a) Manhole cover neoprene rubber joints perished, to be renewed (Rubber joint size: - 520mm x 760mm x08 mm)
020 Manhole cover (b) Manhole cover including coamings perihsed/ thinned to be renewed as per survey report (approx size - 3'x1'8")
020 Manhole cover (c) Manhole Stud nut and bolts with washers corroded/ perished to be renewed.(Size of Stud Bolt -16 mm x 50mm length, 30 nos on each manhole, Mat SS).
020 Manhole cover (d) Handle of manhole covers corroded/ thinned, to be renewed as per survey reports (Mat-MS rod -12 mm thick)
021 APT Air Pressure Test the following tanks and rectify the defects any observed during pressure testing and prove to 0.14 kg/ cm2. Note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. Internal Tank (Note- Priority for below W/L Tanks)
022 Distortion Areas in which distortion of hull structures exceeds 3 times the thickness of plate or 1/20 of the frame spacing (which ever is smaller) shall be renewed. In the areas of dents, the structure shall be inspected for any distortion of the stiffeners inside and cracks by DP test.
023 Circular Fenders -Horizontal fenders Circular rubber fenders perished/cracked, to be renewed whichever is damaged as per NES170 (a) Fenders details are as follows- Mat-EPDM, COLOUR-Black rubber Size- ø250(OD)Xø125(ID)X1600mm Long.
023 Circular Fenders securing arrangment -Horizontal fenders (b) circular Fender securing brackets (Flat bars with MS pad of both ends, Mat- MS corroded/thinned/perishe , to be renewed as per survey reports . Thickenss of the brackets 12 mm
023 Fenders Securing Arrangment (c) Vertical and horizonatl Fender is to be secured with nut and bolt including nylon washer and secured with skirting plate . Size of the nut & bolt length- 400 mm, dia 20 mm for nut and bolt , Mat- MS
023 D Type rubber Fenders -Vertical fenders (d) D" Shaped rubber fenders perished/cracked, to be renewed,as per NES 170 Fenders details are as follows - Mat-EPDM, COLOUR-Black rubber Size of the fenders - 6900 X250X300 MM - 54 NOS
023 Fenders Securing C channel (e) Vertical Fender securing brackets (Flat bars with MS pad of both ends, Mat- MS corroded/thinned/perishe , to be renewed as per survey reports . Thickenss of the brackets 12 mm, 6200 mm X200mm
023 Fenders Securing Arrangment (f) Vertical and horizonatl Fender is to be secured with nut and bolt including nylon washer and secured with skirting plate . Size of the nut & bolt length- 400 mm, dia 20 mm for nut and bolt , Mat- MS QTY- 600 Nos
023 Fenders Securing Arrangment (g) Vertical and horizonatl Fender is to be secured with nut and bolt including nylon washer and secured with skirting plate . Size of Nylon Washer- ø50(OD)Xø21(ID)X3MM Thik- QTY - 1200 Nos
023 Fenders Securing Arrangment (h) Vertical and horizonatl Fender is to be secured with GI chain
023 Fenders Securing Arrangment (j) MS eye fitted on ship side for securing of vertical/horizontal fenders corroed/thinned/holed , to be renewed/repaired as per survey reports
024 Vent pipes and breathers Vent pipes and breaters corroded/thinned/holed , to be renewed /repaired .
025 Dead weight Carryout removal of dead weights to facilitate UW routines and fitted back after routines as required
SOW- IN ASSET -02 001 Docking- Vessel to be docked in both versions. Note 1:- Firms not to quote view docking, undocking and dock blocks preparation will be done by Navy and the job is required to be carried out in Navy Premises Last Undock -Sep 18
002 Hull Cleaning Under Water Free Flood and Boot Top Area HP jet clean entire under water area including free flood area and boot top area (with a pressure not exceeding 3000 PSI) including ship side and remove the mud / marine growth/barnacles and prepare for survey.
002 Hull Cleaning Above Water Area (a) Clean the entire above water area with HP Jet washing (with a pressure not exceeding 3000 PSI) I.A.W. No 01/15 and present for survey
002 Hull Cleaning Weather deck (b) Clean the entire weather deck including deck fittings with HP Jet washing (not exceeding 3000 PSI) I.A.W. No 01/15 and present for survey
002 Hull Cleaning Tanks (c) Manually clean internal tanks i.a.w. No 01/15 and present for survey.
003 Hull survey External and Internal Hull survey. Hull survey. Carry out visual and hammer survey/UTG survey in accordance with NO 19/06 of under water hull, boot top, above water hull, weather decks and all internal tanks etc, all stiffeners and deck fittings including lifting hooks/eyes. Approx area: 2690 Sqm
004 UTG Survey Quote for UTG survey points at u/w hull ,above water and weater deck and internal tanks .
005 Steel Renewals Quote for steel renewal at various locations as per survey report. Note 1:- Quoted repair cost shall include cost of both sides blasted and primed Grade `A’ quality ship building steel for shell and IS 2062 Grade `B’ quality steel for non structural works, renewal of all obstructions in way of steel renewals including minor fittings with their foundations, etc., as indicated by survey team / RMT, proving of the weld runs by non-destructive tests and by hose test on completion of welding, pressure testing and proving of tanks where steel renewal undertaken etc.
006 Build ups Carry out build ups as indicated by the Hull survey team/ Surveyor (a) Approx size 25x25 mm-250 Nos
006 Build ups Carry out build ups as indicated by the Hull survey team/ Surveyor (b) Approx size 50x50 mm - 150 Nos
007 Fairing Carryout fairing of deformed structures as indicated by Hull Survey Team/ Surveyor
008 Re-welding run Carry out re-welding runs on weld seams as indicated by Hull survey team/ QC/ RMT.
009 Draught Marks Draught marks corroded/eaten away, to be renewed and painted. Both Roman and Numeric.
010 Sacrificial Anodes Renew Sacrificial anodes (MK I) those consumed more than 50% Note:- Anodes Navy/COY supply.
011 Surface preparation with Grit Blasting Under Water area including free flood area and Boot top area Spot blasting to SA 2.5 on paint damaged areas/ renewed plate areas as per the paint OEM rep recommendation for paint application.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Primer - penguard primer - 50 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Anti Corrosive - Jotacote Universal (Aluminium) - 150 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Anti Corrosive - Jotacote Universal (grey) - 150 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat: Tie Coat: Safeguard ES - 125 microns Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (e) 5th Coat: A/F:Sea Quantum Pro U and Spectrum 150 microns (Light Red/Dark Red) Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (f) 6th Coat: A/F: Sea Quantum Pro U and Spectrum 150 microns (Light Red/Dark Red) Pontoon was manufacture in 2010. Life of U/W paint scheme is 10 Years. However full paint is to be renewed.
012 Painting - Jotun Scheme Under Water area including free flood area and Boot top area Paint under water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (g) 7th Coat: A/F: Seaquantum Ultra( Black) - 2 X 150 microns
013 Surface Preparation Above Water Area Carry out surface preparation w on above water area to SA2.5 standard under the suprvision of paint OEM.
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Penguard primer - 50 microns DFT
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Jotamastic(Grey/ Red Brown) - 125 microns DFT
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Jotamastic(Grey/ Red Brown) - 125 microns DFT
014 Painting - JOTUN Scheme. Above Water Area Paint above water area with following paint scheme as per OEM recommendations:-Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat: Hard Top XP Grey - 60 microns DFT
015 Surface Preparation Weather Decks and Fittings Carry out Surface pre[partion to WJ 2 standard as per survey report of Paint OEM for paint application for entire weather deck.
016 Painting - JOTUN Scheme Weather Decks and Fittings Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Penguard Primer -50 microns DFT
016 Painting - JOTUN Scheme Weather Decks and Fittings Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Jotamastic 87 of 200 microns
016 Painting - JOTUN Scheme Weather Decks and Fittings Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Jota Armour Dark grey of 800 microns
017 Surface Preparation Internal Tanks Carry out Grit blasting to SA 2.5 standard at paint defective area/ as survey report of Paint OEM for paint application.
018 Painting - JOTUN Scheme Paint all internal tanks with following paint scheme Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Penguard Primer -50 microns DFT
018 Painting - JOTUN Scheme Paint all internal tanks with following paint scheme Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Anticorrosive Balloxy (HB light) - 150 microns
018 Painting - JOTUN Scheme Paint all internal tanks with following paint scheme Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Anticorrosive Balloxy (HB light) - 150 microns
019 Deck Fitting Fair lead (MS cleats) including base plate corroded/perished, to be renewed as per survey report (a) Size of eye plate- 230x550x20 mm thick plate,
019 Deck Fitting Twin bollards on weather deck including base plate corroded/perished, to be renewed as per survey report (b) Twin Bollard size dia- 400x800x20 mm height
019 Deck Fitting Twin bollards on weather deck including base plate corroded/perished, to be repaired as per survey report (c) Twin Bollard size dia- 400x800x20 mm height
020 Manhole cover (a) Manhole cover neoprene rubber joints perished, to be renewed (Rubber joint size: - 520mm x 760mm x08 mm)
020 Manhole cover (b) Manhole cover including coamings perihsed/ thinned to be renewed as per survey report (approx size - 3'x1'8")
020 Manhole cover (c) Manhole Stud nut and bolts with washers corroded/ perished to be renewed.(Size of Stud Bolt -16 mm x 50mm length, 30 nos on each manhole, Mat SS).
020 Manhole cover (d) Handle of manhole covers corroded/ thinned, to be renewed as per survey reports (Mat-MS rod -12 mm thick)
021 APT Air Pressure Test the following tanks and rectify the defects any observed during pressure testing and prove to 0.14 kg/ cm2. Note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. Internal Tank (Note- Priority for below W/L Tanks)
022 Distortion Areas in which distortion of hull structures exceeds 3 times the thickness of plate or 1/20 of the frame spacing (which ever is smaller) shall be renewed. In the areas of dents, the structure shall be inspected for any distortion of the stiffeners inside and cracks by DP test.
023 Circular Fenders -Horizontal fenders Circular rubber fenders perished/cracked, to be renewed whichever is damaged as per NES170 (a) Fenders details are as follows- Mat-EPDM, COLOUR-Black rubber Size- ø250(OD)Xø125(ID)X1600mm Long.
023 Circular Fenders securing arrangment -Horizontal fenders (b) circular Fender securing brackets (Flat bars with MS pad of both ends, Mat- MS corroded/thinned/perishe , to be renewed as per survey reports . Thickenss of the brackets 12 mm
023 Fenders Securing Arrangment (c) Vertical and horizonatl Fender is to be secured with nut and bolt including nylon washer and secured with skirting plate . Size of the nut & bolt length- 400 mm, dia 20 mm for nut and bolt , Mat- MS
023 D Type rubber Fenders -Vertical fenders (d) D" Shaped rubber fenders perished/cracked, to be renewed,as per NES 170 Fenders details are as follows - Mat-EPDM, COLOUR-Black rubber Size of the fenders - 6900 X250X300 MM - 54 NOS
023 Fenders Securing C channel (e) Vertical Fender securing brackets (Flat bars with MS pad of both ends, Mat- MS corroded/thinned/perishe , to be renewed as per survey reports . Thickenss of the brackets 12 mm, 6200 mm X200mm
023 Fenders Securing Arrangment (f) Vertical and horizonatl Fender is to be secured with nut and bolt including nylon washer and secured with skirting plate . Size of the nut & bolt length- 400 mm, dia 20 mm for nut and bolt , Mat- MS QTY- 600 Nos
023 Fenders Securing Arrangment (g) Vertical and horizonatl Fender is to be secured with nut and bolt including nylon washer and secured with skirting plate . Size of Nylon Washer- ø50(OD)Xø21(ID)X3MM Thik- QTY - 1200 Nos
023 Fenders Securing Arrangment (h) Vertical and horizonatl Fender is to be secured with GI chain
023 Fenders Securing Arrangment (j) MS eye fitted on ship side for securing of vertical/horizontal fenders corroed/thinned/holed , to be renewed/repaired as per survey reports
024 Vent pipes and breathers Vent pipes and breaters corroded/thinned/holed , to be renewed /repaired .
025 Dead weight Carryout removal of dead weights to facilitate UW routines and fitted back after routines as required
SERVICES Docking and undocking charges (Both Versions) Firm not to quote. Docking and Undocking will be done by Navy in Navy Permises i.e ND(V) /slipway.
Dock blocks preparation & laying out as per docking plan Firm not to quote. Job will be done by Navy .
Dock hire charges for an estimated duration of Days as per OCR Firm not to quote. Dry Dock facility will provided by Navy in Navy Permises i.e ND(v) /slipway.
Wet basin/alongside hire charges for the remaining duration (i.e. total refit duration of – days docking period) Firm not to quote. Dry Dock facility will will provided by Navy in Navy Permises
Quote for maintenance of two in no. fire lines for the refit duration . Firm to quote.
Provision of two transports (cars) for entire refit duration (one for refit Co-ordinating staff and one for ND(V) monitoring Team) for 12 hrs or 100KM/day whichever is less Firm to quote.
Provision of stationory / office items for ND(V) / Refit monitoring team for entire refit duration period. Cater budget of Rs 2000/- per month. Requirement will be intimated RMT/ NDV on as requirement basis. Payment at actuals. Note:- firms to quote.
QC inspection for the entire scope of work by third party IRS/LRS/ABS/QC/TPI for the refit duration as per the QIS. Firm not to quote. Services will be provided by ND(V)/QC
M/s Dynatron services Private Limited
MANIMADHAVI ENTERPRISES
India Maritime Services
WINTECH ENGINEERING WORKS
avisan engineering enterprises
SAGAR SHIP REPAIRERS AND MARINE SERVICES
Sadhav Offshore Engineering Company
ADHYANTA ENGINEERING PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .