Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance M 2041 SEC 25 AKSHAR BUSINESS PARK VASHI NAVI MUMBAI VASHI THANE MAHARASHTRA 400703 INDIA | THANE | MAHARASHTRA | 400703 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
31 Jan 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager SRC-Com
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
Servicing of Main Switch Board and Emergency Switch Board on MV Vishva Vijetha
2022_HSL_88760_2
20 / 22002 / MSB and ESB / 193 / 2021-22
Open Tender
Miscellaneous Services
Service
20 days
HSL Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
2 Feb 2022
25 Jan 2022
31 Jan 2022
25 Jan 2022
31 Jan 2022
25 Jan 2022
120 days
Amount
E21057: ITEM:MAIN SWITCHBOARD AND EMERGENCY SWITCH BOARD
BOTH MAIN SWITCH BOARDS AND EMERGECY SWITCH BOARD TO BE THOROUGHLY CLEANED USING DRY AIR AND ELECTRIC CLEANER (YARD SUPPLY).
INSULATION OF MSB & ESB TO BE CHECKED BEFORE AND AFTER THE CLEANING TO BE RECORDED AND SUBMIT.
THE PANEL AND CIRCUIT INSULATION FOUND POOR INSULATOR TO BE REMOVED BY SPARES. SPARES SHALL BE SUPPLED BY SHIP.
TO CARRY OUT SERVICING AND CALIBRATION OF FOLLOWING MSB METERS.CALIBRATION REPORT TO BE SUBMITTED FOR THE CALIBRATED METERS.DEFECTIVE METERS TO BE REPLACED BY THE CONTRACTOR
a) AMMETER
b) VOLTMETER
c) WATTMETER
d) INSULATION METER
e) FREQUENCY METER
TIGHTNESS OF ELECTRICAL CONNECTIONS , NUTS & BOLTS IN M.S.B TO BE TIGHTENED
SERVICING AND CALIBRATION OF 5 NO’S AIR CICUIT BREAKERS FOUR OF MAIN SWITCH BOARD AND ONE IN EMERGENCY SWITCH BOARD.CALIBRATION REPORT TO BE SUBMITTED FOR THE CALIBRATED ACBs
ALL SWITCHBOARD SAFETIES TO BE TESTED AND SHOWN IN OPERATION AFTER CLEANING OF SWITCHBOARD.--REVERSE POWER TRIP;UNDERVOLTAGE; OVERCURRENT; SHORT CURCUIT;PREFERENTIAL TRIP;LOW INSULATION AND SAME TO BE PROVED IN PRESENCE OF THE SHIP/SURVEYOR
ALL ALTERNATORS AUTO STARTING SYSTEM/STANDBY STARTING SYSTEM TO BE CHECKED AND REPAIRED.DEFECTIVE MATERIAL TO BE REPLACED BY THE CONTRACTOR
THE LIGHTING TRANSFORMERS IN ENGINE ROOM AND IN EMERGENCY GEN. ROOM TO BE SERVICED CLEANED AND IMPROVE THE INUSLATION IF LOW AND TIGHTNESS OF THE CABLES TO BE CHECKED.
ALL THREE GENERATORS PARALLEL OPERATION TO BE CHECKED IF NECESSARY AND ANY ADJUSTMENT ON AVR TO BE CORRECTED IF REQUIRED.DEFECTIVE MATERIAL TO BE REPLACED BY THE CONTRACTOR
EMERGENCY GENERATOR AUTO OPERATION TO BE CHECKED AND RECTIFY THE SAME.DEFECTIVE MATERIAL TO BE REPLACED BY THE CONTRACTOR
BOTH 440 V AND 220 V SHIPBOARD SUPPLY INSULATION TO IMPROVE.DEFECTIVE MATERIAL TO BE REPLACED BY THE CONTRACTOR
E21054 ITEM : ELECTRICAL METERS
AMMETERS FOR THE FOLLOWING MACHINERIES TO CALIBRATE; ERRORS TO BE RECTIFIED & CALIBRATION REPORTS/CERTIFICATES TO BE SUBMITTED.DEFECTIVE METERS TO BE SUPPLIED AND REPLACED BY THE CONTRACTOR.
MAIN AIR COMPRESSOR : 0-150/200 AMP
M.E. AUX. BLOWERS : 0-100/600 AMP
ME L.O P/P : 0-200/1000 AMP
MAIN BALLAST P/PS : 0-150/750 AMP
E/R VENT FANS: 0- 50/250 AMP
STEERING MOTORS : 0-150/450 AMP
EMCY E.R. VENT FAN: 0-40/240AMP
WINDLASS :0-200/1200 AMP
MOORING :0-75/450 AMP
M/E JCW P/PS:0-40/200 AMP
EMCY FIRE P/P MOTOR:0-75/375 AMP
PURIFIERS H.O/D.O:0-20/40 AMP
PURIFIERS G/E LO:0-15/30 AMP
PURIFIERS M/E LO:0-10/20 AMP
TURNING GEAR MOTOR : 0-15/90 AMP
WATER MIST MOTOR : 0-15/45 AMP
ACCOMODATION A.C BLOWER MOTOR : 0-30/60AMP
ACCOMODATION A.C. COMPRESSOR MOTOR : 0-100/200 AMP
HYDRUALIC PUMP HATCH COVER PANEL : 0-50/100 AMP
DOM.FRIDGE COMPRESSOR MOTOR : 0-20/40 AMP
FIRE & BILGE G.S. P/P MOTOR : 0-120/600 AMP
COOLING S.W. P/P MOTOR : 0-37.5/73 AMP
M.D.O AND H.F.O. TRANSFER P/P MOTOR : 0-50/250 AMP
L.T.C.F.W P/P MOTOR : 0-200/1000 AMP
HARBOUR L.T.C.F.W P/P MOTOR : 0-100/500 AMP
SERVO OIL SERVICE P/P MOTOR : 0-10/60 AMP
TACHOMETERS FOR MAIN ENGINE AND ALL THREE AUX.ENGINES TO BE CALIBERATED AND ERRORS TO BE RECTIFIED/ADJUSTED AND CERTIFCATION TO BE DONE FOR FOLLOWING NOS. OF TACHOMETERS
a) M.E:2 NOS.(IN ECR) + 4 NOS.(IN BRIDGE)
B) AUX.ENGINE: 3 NOS
QUOTE FOR INSTALLATION OF NEW TACHOMETERS OF EACH TYPE,IN CASE THESE ARE FOUND BEYOND REPAIR.
DELTA MARINE ENGINEERS
SHARP ELECTRICAL AND MECH ENGG SERVICES
SRI VINAYAKA MARINE SERVICES
AKSHAY CONTROLS AND SYSTEMS PVT. LTD.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .