Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC 80 STATION PALLY DANKUNI HOOGHLY 712331 | 712331 | L1 | Accepted-AOC Qualified | |
| 2 | L2₹31.6 L+₹4.5 L (16.6%)Rejected-Finance TARULIA 3RD LANE P O KRISHNAPUR KOLKATA 700102 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700102 | L2 | Rejected-Finance Disqualified | |
| 3 | L3₹31.8 L+₹4.7 L (17.3%)Rejected-Finance KANSARI PARA KALNA PURBA BARDHAMAN | L3 | Rejected-Finance Disqualified | |
| 4 | L4₹32.8 L+₹5.7 L (20.9%)Rejected-Finance BARASAT HOUSING ESTATE PH II P O NOAPARA KOLKATA 700 125 | 24 PARAGANAS NORTH | WEST BENGAL | 700125 | L4 | Rejected-Finance Disqualified |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
27 Jan 2025, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer
NKDA Administrative Building
Repair and upgradation of damaged cables and luminaries at Buddhadeb Park, Tarulia Park and AC park at AA-I, New Town Kolkata under NKDA
2025_NKDA_798924_1
WBNKDA/34/EE-E/NKDA OF 2024-25
Open Tender
Miscellaneous Services
Item Rate
New Town, Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹54,000
NKDA Administrative Building
15 May 2025
11 Jan 2025
29 Jan 2025
11 Jan 2025
27 Jan 2025
11 Jan 2025
15 Jan 2025
Amount
Supply and fixing of 230V,60W, IP-65/66 Protected LED Post top with all necessary interconnection and earthing attachment as directed by the EIC. [Make:Crompton/Havells/Phillips][Post Top][Analysis]
Supply and fixing of 230V,IP-65/66, 15 W Protected LED Up Down Wall Light with all necessary interconnection and earthing attachment as directed by the EIC [Make Make:Bajaj/Havells/Murphy][Up-Down Light][Analysis]
Supply and fixing of 230V,4-5W, IP-65/66 Protected LED Spike Light with all necessary interconnection and earthing attachment as directed by the EIC. [Make: Make:HPL /Havells/Orient] [Analysis]
Fixing only Light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4.2.1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and Gl earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly upto 9 Mtr size 0.6x0.6x1.70 mts
Supply and installation of 1.2m long GI Earth spike (Approved)
Connecting the equipments to earth busbar including S & F 8 SWG GI(Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nut, washer, cable lugs etc. as required and mending good damages
Supply and delivery at site of follwing cable PVC/XPLE armoured copper conductor (LP) cable, confirming IS:1554 ( Part-1)/1976. 4 core X 2.5 Sqmm (Make:Gloster/Havells/Mescab)[Analysis]
Supply and delivery of 1.1 KV Grade PVC/XLPE insulated 4C 16 SqmmA1 Ar cable(Make:Gloster/Havells/Mescab/KEI)[Analysis]
Laying of one No. cable upto 35 sqmm in undergroung trench 460 mm eide x 760mm average depth. With brick protection on the top of the cable with 8(eight) Nos bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil. leveling up and restoring surface duly rammed
Laying of 1.1 KV grade PVC/XLPE insulated strandred conductrorvthrough Micro tunneling/pipe/ pole/ piller boxes.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [2.5Sqmm]
Supply and fixing of Gland for 4C 16 Sqmm A1 Ar Cable as per Government Schedule
Supplying & Erection of medium size feeder pillar box of Size (1200 x 750 x 450 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C
Earthing with 50 mm dia GI pipe(ISI-M) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13mm dia x 80 mm long Gl bolts. double nuts, double washers incl. S & F 15 mm dia Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
M/S DEEP ENTERPRISE (BID ID -6051783)
BHABANI CONSTRUCTION (BID ID -6003226)
D.B ENTERPRISE (BID ID -6027582)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .