Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.5 L
EMD Value
₹5,002
Closing Date
22 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Middle school Bhat Mohalla Audoora B.W.O Construction of DLB at MS Audoora Baramulla Electric work
2025_PWDJK_298053_1
NIT No.220/2025-26 Dt/12/12/2025
Open Tender
Electrical Works
Percentage
Audoora Baramullah
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹5,002
12 Dec 2025
12 Dec 2025
23 Dec 2025
12 Dec 2025
22 Dec 2025
12 Dec 2025
Wiring for light point / exhaust /ceiling fan point with (P+N) 2X1.5 sq.mm FRLS-H ( Polycab/Havells/eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor/polycab/Ravindra/equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban/legrand mylinc/SSK NV/ABB Tvisha/ eq. make as approved by site engineer), modular plate, cover in front and suitable GI box etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 2.5Sqmm Multi strand Copper wire from Switch board to D.B complete. including cost of Conduits.
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate (Anchor roma urban/legrand mylinc/SSK NV/ABB Tvisha / eq. make to be approved by EIC
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab / eq. make to be approved by EIC) (Including Cost of Conduit/Channel)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified (Anchor roma urban/legrand Mylinc/SSK NV/ABB Tvisha/ eq. make & shall be approved before execution of work.
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor / eq. make to be approved by EIC) (Including Cost of Conduit/Channel)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified (Anchor roma urban/legrand Mylinc/SSK NV/ABB Tvisha/ eq. make & shall be approved before execution of work.
SINGLE POLE (6-32Amp) MCB Legrand /Havells or L&T /Schneider/ABB / eq. make to be approved by EIC
Supplying and fixing following rating, Double pole, (P +N) 240 V, C* Curve Residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.
100 Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens / eq. make to be approved by EIC ( For inverter circuit)
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens / eq. make to be approved by EIC
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens / eq. make to be approved by EIC
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK / eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
Supply installation testing and commissioning of 18 W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips or Havells or Wipro / eq. make to be approved by EIC
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ Eq Make
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfacel recessed medium class PVC conduit as required of Havells/Polycab/Anchor / eq. make to be approved by EIC including cost of conduit
2 X 16 sq. mm (for supply from incoming DP to first floor DB)
S/L , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
d) 25 sq.mm 2 core ( armoured)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.04 MB
BOQ_965961.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .