Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹93.4 LAccepted-AOC 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹94.3 L+₹83,190 (0.89%)Rejected-Finance PLOT NO 113 GURUSANGAT DARBAR ROAD SINDHI COLONY KHAMLA NAGPUR 440025 | NAGPUR | MAHARASHTRA | 440025 | L-2 | Rejected-Finance Quoted High | |
| 3 | L-3₹1.0 Cr+₹7.0 L (7.54%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-3 | Rejected-Finance Quoted High | |
| 4 | L-4₹1.1 Cr+₹13.5 L (14.4%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L-4 | Rejected-Finance Quoted High | |
| 5 | L-5₹1.1 Cr+₹13.9 L (14.9%)Rejected-Finance 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | L-5 | Rejected-Finance Quoted High |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
28 Mar 2022, 3:00 pmClosed
AGM (Engg-Elect)
NIATAM, Birsi Airport, Gondia
ARMO of E ,M Installations and CMC of Split AC and Water Cooler etc at NIATAM, Gondia for 2 years (2022-24)
2022_AAI_107781_1
AAI/NIATAM/E-E/2021-22/NIT-06
Open Tender
Miscellaneous Services
Item Rate
730 days
Maintenance/Gondia
As per NIT
4 documents required · 4 mandatory
₹1,180
Yes
Airports Authority of India
₹2.4 L
Yes
18 May 2022
3 Mar 2022
29 Mar 2022
3 Mar 2022
28 Mar 2022
9 Mar 2022
3 Mar 2022 - 9 Mar 2022
Amount
Annual Operation & Maintenance of various Electrical Installations of NIATAM such as Institute, Mens hostel, Womens Hostel Staff Houses, Canteen, AAI Residential colony, DG Sets up to 500 KVA with AMF Panels, Power Supply Systems, 11KV Sub-Station, Water Supply & Pump House, Street Lights, Parking Lights, Internal & External installations of Power House etc. including repair & maintenance, Faults/ breakdown rectifications, ensuring serviceability/ Satisfactory working conditions of the system, attending complaints as per scope of work given in special conditions of contract on all days including Sunday & Holidays (i.e in three shifts daily, each shift of 8 hours) etc. complete as required.
Complete Rewinding, Servicing, Repairing of Ceiling Fan/ Wall Fan including replacement of bearings if required and to&fro transportation etc complete as required. (Dismantle Material belongs to contractor).
1st Year
2nd Year
Complete Rewinding, Servicing, Repairing of Exhaust fan/ Air Circular fan as following of sizes i/c replacement as bushes/bearings if required and to & fro transportation etc complete as required. (Dismantle Material belongs to contractor) Up to 450 mm Sweep
1st Year
2nd Year
Complete Rewinding of the following motors, Which are suitable to operate on 230V, 50Hz, 1Ø AC supply, with suitable gauge copper wire i/c varnishing and bearing if required etc as required i/c transportation from site to workshop & back to site. (Dismantle Material belongs to contractor and agency shall be responsible for rewinding and repairing of motor pump set for 6 months). Motor upto 2 HP capacity
1st Year
2nd Year
Complete Rewinding of the following motors, Which are suitable to operate on 415V, 50Hz, 3Ø AC supply, with suitable gauge copper wire i/c varnishing and bearing if required etc as required i/c transportation from site to workshop & back to site. (Dismantle Material belongs to contractor and agency shall be responsible for rewinding and repairing of motor pump set for 6 months). Motor Above 3 HP and upto 5 HP capacity
1st Year
2nd Year
Lifting & Lowering of submersible pumps of various capacities (up to 5 HP) due to defect in existing pump on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing &commissioning complete as required.
1st Year
2nd Year
Complete Repair and rewinding of submersible pump motor set up to 3 HP Job including transportation of motor dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn out/defective parts i.e bushes, impellers, sleeves, upper and lower bush sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required. (Dismantle Material belongs to contractor and agency shall be responsible for rewinding and repairing of motor pump set for 6 months).
1st Year
2nd Year
Inspection, Servicing and Testing of 3 Pole, 630Amp, 11 KV Vacuum Circuit Breakers (Make : Siemens) including carrying out tests & preventive maintenance through Manufacture OR Authorised Service agent and submission of test reports.
1st Year
2nd Year
Inspection, servicing, setting, calibration and testing of IDMT relays (Make- ABB, Model- NI40) (set of 2 over current + 1 earth fault) i/c carrying out tests & preventive maintenance through authorised service agent and submission of test reports.
1st Year
2nd Year
Inspection, servicing, setting, calibration and testing of Microprocessor based numerical relay (Make L&T, Model MC31A, MC 61A) with O/L, E/F and S/C protections for 11KV panel i/c carrying out preventive maintenance through authorized service agent and submission of test reports.
1st Year
2nd Year
Inspection, servicing, setting, calibration and testing of auxiliary and tripping relays including carrying out preventive maintenance through authorised service agent and submission of test reports.
1st Year
2nd Year
Inspection, Testing & preventive maintenance of 11 KV Potential transformers including carrying out preventive maintenance through authorized service agent and submission of test reports.
1st Year
2nd Year
Inspection, servicing & testing of Air circuit breakers Make GE, Capacity 1600A including carrying out the testing and preventive maintenance through authorized service agent and submission of test reports.
1st Year
2nd Year
Inspection, servicing & testing of Air circuit breakers Make L&T, Capacity 800A including carrying out the testing and preventive maintenance through authorized service agent and submission of test reports.
1st Year
2nd Year
Dehydration and filtration of transformer oil at site including testing the BDV and acidity before and after testing, topping of oil and submission of test reports etc. as required for following Transformers. (a) Make: Crompton Greaves, Capacity 1000 KVA, Oil Capacity 580 Ltrs.]
1st Year
2nd Year
Supply of tested transformer oil for topping up in transformers as required.
10 round pin Socket suitable for Single Phase, 240V, 50Hz, AC Supply.
10/16A Socket suitable for Single Phase, 240V, 50Hz, AC Supply.
2 Modular Plates with Base Frame (Make MK or equivalent )
3 Modular Plates with Base Frame (Make MK or equivalent )
4 Modular Plates with Base Frame (Make MK or equivalent )
8 Modular Plates with Base Frame (Make MK or equivalent )
Modular Blanking plate for switch board. (Make MK or equivalent )
6A, 1-Way Modular Switch Suitable for Single Phase, 240V, 50Hz, AC Supply.
16A, 1-Way Modular Switch Suitable for Single Phase, 240V, 50Hz, AC Supply.
6A, 2in1 Socket, 2M, Modular Socket Suitable for Single Phase, 240V, 50Hz, AC Supply.
16A, 3 pin Socket, 2M, Modular Socket Suitable for Single Phase, 240V, 50Hz, AC Supply.
Geyser Element 1.5kw/2kw for multistar water geyser 25 ltr.
2.5 MFD Capacitor suitable for 240V, 50 Hz, single phase AC Supply. (Make Havells or equivalent)
5W Holder type LED bulb, suitable for operation on 230V +/- 10%, 50 Hz., AC supply.
18W Holder type LED bulb, suitable for operation on 230V +/- 10%, 50 Hz., AC supply.
Automatic changeover switch 1f, mains 30A similar to Model No. AUCL01030030 (Make-L&T or equivalent)
Door/ Call bell 240V (Ding Dong, Make- Anchor or equivalent )
1.5 Sqmm PVC insulated single core multi strand Copper conductor FR industrial cable confirming to IS-694: 1990 for voltage up to 1100V [90 Mtr Coil]
2.5 Sqmm PVC insulated single core multi strand Copper conductor FR industrial cable confirming to IS-694: 1990 for voltage up to 1100V [90 Mtr Coil]
4.0 Sqmm PVC insulated single core multi strand Copper conductor FR industrial cable confirming to IS-694: 1990 for voltage up to 1100V [90 Mtr Coil]
Spike Guard with 6 universal socket shutter suitable for Single Phase, 240V, 50Hz, A.C Supply.
24" Geyser Pipe for Geyser.
100A, 36KA, Four Pole MCCB suitable for Three Phase, 415V, 50Hz, AC Supply.
63A, Four Pole MCB suitable for Three Phase, 415V, 50Hz, AC Supply.
40A, TP MCB suitable for Three Phases, 415V, 50Hz, AC Supply.
40A, DP Isolator suitable for Three Phases, 415V, 50Hz, AC Supply.
Analogue Timer Switch for Street Light Panel.
Execution of works as per CPWD DSR (E&M) 2018, DAR (E&M) 2018 & Latest CPWD Specifications as & when required. CPWD DSR (E&M) - Chapter 1 to 10 & 14
Annual Comprehensive Maintenance of following capacity Split type room Air conditioner Units (Excluding compressor) of different makes installed at different locations as per terms and conditions attached.
1.5 TR Split Type AC - 1st Year
2.0 TR Split Type AC - 1st Year
1.5 TR Split Type AC - 2nd Year
2.0 TR Split Type AC - 2nd Year
Annual Comprehensive Maintenance of following capacity Split type room Air conditioner Units (Including compressor) of different makes installed at different locations as per terms and conditions attached.
1.5 TR Split Type AC - 1st Year
3.0 TR Tower Type AC - 1st Year
4.0 TR Tower Type AC - 1st Year
4.0 TR CasetteType AC - 1st Year
1.5 TR Split Type AC - 2nd Year
3.0 TR Tower Type AC - 2nd Year
4.0 TR Tower Type AC - 2nd Year
4.0 TR CasetteType AC - 2nd Year
Annual Comprehensive Periodical maintenance of Water cooler Units (Including compressor) of 40/80 ltr capacity, 1Ø, 230 V, 50 Hz, of different makes including stabilizer(if any) installed at different locations including providing all necessary consumable, refrigerant Gas and spares etc.
1st Year
2nd Year
Annual Comprehensive maintenance contract of 1 No. U.V. water purifier (Make Hi-Tech) having flow rate 3 ltr per minute, comprising of U.V. lamps, Membrane Filter, Paper Filter, SMPS, etc. complete as required.
1st Year
2nd Year
Annual Comprehensive maintenance contract of KENT RO (Model- Kent ACE) having storage capacity 7 Ltr., comprising of U.V. lamps, Carbon filter, Sediment Filter, Membrane Filter, Post Carbon Filter, Pre Carbon Filter, SMPS, CC Kit Pump etc. complete as required.
1st Year
2nd Year
M/s BHARAT ELECTRIC, NAGPUR
Manish Electricals
Techno Electricals
NATIONAL SAFETY ENGINEERS
CIS GLOBAL INFRATECH PRIVATE LIMITED
PREMIER ENGINEERING TECHNICS PVT. LTD.
CHENNAI ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .