GE Ranikhet
GE MES Ranikhet
SPL REPAIRS TO OR LIVING (OTM) BLDG NOS T 159 T 156 T 70 AND T79 OF C COMP SIG REGT AT KAUSANI UNDER GE RANIKHET
2022_MES_528409_1
GE/RKT/29 OF 2022-23
Open Tender
Civil Works
Works
180 days
Kausani under GE Ranikhet
As per NIT
6 documents required · 6 mandatory
₹500
GE Ranikhet
₹42,100
16 Aug 2022
3 Jun 2022
2 Jul 2022
3 Jun 2022
30 Jun 2022
17 Jun 2022
Amount
BOQ (Sch 'A') Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tiles exc 0.11 sqm but not exc .18 sqm (size 400 X 400 x 7 mm thick), as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, complete all as specified and directed.
All as per item no 3 here-in-before but as in skirting/dado/ on vertical surfaces complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:4 for backing of Dado/ Skirting complete all as specified and directed.
M & L for glazed ceramic coloured / printed tiles 300mm x 450mm, 6 to 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and directed.
M&L for 9mm thick plywood, grade BWR, type BB fixed with rawl plug and screws to timber framework . fixed as in wall and floor fixed in repairs complete all as specified and directed.
S&F cover fillets 4.5mm thick of standard hard board 40 mm wide and fixing with screws complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid dry or laid dry and pointed complete all as specified and directed.
M & L for machine cut Kota stone slab flooring 20 – 25mm thick over and including cement screed base 20mm thick in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for granite (of any type) tiles 18 to 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in cooking platforms and WHB plateform and like complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channel or drain complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15 cm thickness below or above ground level complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, finishing the top surface even and smooth without using extra cement, laid in bays with and including necessary form work complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base, complete all as specified and directed.
M & L for cement concrete chequered tiles, 300x300x25 mm thick with grey cement and pigment as in floor, footpath, set and jointed in neat cement slurry and pointed with coloured cement to match the shade of tile over and including 15mm thick bedding layer in CM 1:4 complete all as specified and complete all as specified and directed.
M&L for PCC 1:3:6 type C-I (using 20 mm graded stone aggregate) as in coping /kerb/Side of interlocking tiles etc.including weathering and throating including necessary form work etc.complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry surfaces in cement mortar 1:4 and finished even and smooth without using extra cement includig mixing of water proofing compound of approved make as per manufacturer's instructions complete all as specified and directed.
M & L for 15mm thick rendering in cement mortar 1:6, surface finished even & smooth with thin layer of sagol over a dubbing out average 10mm thick on irregular face of walls,complete all as specified and directed.
M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of primer(Priming the plastered and other surface with Birla putty preparatory to distempering) complete all as specified and directed.
M&L for preparing newly and old plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer (Priming the plastered and other surface with alkali resistant priming paint) complete all as specified and directed. Note- Old painted surface shall be completely removed by brushing, washing etc)
Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified and directed.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
M & L for Preparation of old painted steel and iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of new or previously untreated steel and iron surfaces painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed.
M&L for cutting chases for water tubing concealed , etc, and making good to facings where required and plastering in cement mortar (1:4) cutting not exceeding 10cm girth in stone/concrete block or brick wall complete all as specified and directed.
S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all GI fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
Refixing of old 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc) complete all as specified and directed.
S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239 (Part -1) including all GI fittings such as bends,tees,short pieces, connectors, elbows, reducers, union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
Refixing of old 20 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc complete all as specified and directed.
S&F in repairs stop valves, cast copper alloy, fency type chromium plated with long shank & cup (concealed) , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and directed.
S&F vitreous china wash basin size 550x400mm white excluding taps , waste but including brackets or erecting stands, complete all as specified and directed.
S & F in repairs 15mm bore pillar tap fancy type, cast copper alloy with capstan head, chromium plated screwed down, high pressure with or without lettered “hot “ or “cold” with long screwed shanks and fly nut complete all as specified and directed.
S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified.
S&F in repairs vitreous China squatting pan, 'Orrissa' pattern, size 580 mm x 440 mm white, with integral foot rests (excluding flushing cistern, flush pipe and waste pipe) and ‘P’ or ‘S’ trap front or back inlet including concrete bedding, complete all as specified and direrected.
S&F in repairs PVC low level flushing cistern, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets, connection to pipe all as directed complete all as specified and directed.
S&F in repairs 600mmx450mm looking mirror PVC moulded and fixed to wooden plug with CP brass screws and cup washers complete all as specified and directed.
M & L for 32mm bore high density polyethylene pipes (HDPE) 600 mm long complete all as specified and directed.
M&L for 75mm dia PVC nahani trap or floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed.
S & F in repairs 100mm bore cast iron soil, waste and vent pipes sand cast pipes in any length with or without ears, with cement joints fixed to wall complete all as specified and directed.
S & F 100mm bore Cast iron bends of any radius diminishing piecec or tapers (larger bore measured) complete all as specified and directed.
S & F 100mm dia Cast iron cowls complete all as specified and directed.
S & F in repair 75mm bore Cast iron soil, waste and vent pipes sand cast pipes , in any length with or without ears, with cement joints fixed to wall complete all as specified and directed.
S & F 75mm bore Cast iron bends of any radius diminishing piecec or tapers (larger bore measured) complete all as specified and directed.
S & F Salt-glazed stoneware gully traps, Size 100x100 mm square or round mouthed, type P /S incl setting and jointing to drains with cement mortar 1:1 with and including all excavation and eartwork in any type of soil, PCC 1:2:4, type B-1, as in beds surrounds, kerbs etc complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar 1:1 to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends complete all as specified and directed.
Dismatling & Disconnecting existing PVC tank exc 250 Ltr and n. exc 500 Ltr complete all as specified and directed.
S & F rotational moulded PVC water storage tanks 500 Ltrs capcity three layered in any colour (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S and F Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Dismantling of boarding , any description fixed in any position complete all as specified and directed.
S & F Second class hardwood 25 mm thick boarding plain one side with butt joint fixed with nails in any situation complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in framed work complete all as specified and directed .
M&L for timber framed and fixed 2nd class hard wood clean sawn scantlings fixed in any position complete all as specified and directed.
Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strenth of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws or fixed with L type or J- type or crannked hooks bolts complete all as specified and directed.
S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strenth of 550 Mpa as in roof covering / clading to wall , fixed with self tapping screws or fixed with L type or J- type or crannked hooks bolts complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
S & F powder coated GI Everest ceiling grid system of grid size 600 X 600 mm fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the Main Tee 28x24x0.3mm thick, Cross Tee 28x24x0.3mm thick and Wall angle 24x24x0.3mm thick sections complete all as specified and directed.
S & F 4 mm thick Everest designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 595 X 595 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed.
Dismantling of CI or reinforced concrete drain pipes,150 mm dia jointed in cement mortor and taking out of trenches complete all as specified and directed.
M & L 150 mm dia Salt Glazed stone ware drain pipes grade 'A' laid in trenches and jointed as specified complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded stone stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed.
Removing Excavated soil exceeding 250 m but not exceeding 1.50 Km and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Dismantling mild steel work of any description complete all as specified and directed.
S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and similar work conforming Fe 410-W (Gde-E-250) quality-A complete all as specifies and directed
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided (Reinforcement cut as requried to facilitate demolition) complete all as specified and directed.
S&F TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for RCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in precast cover slab for manholes, drains, channels etc set in cement mortar 1:4 including necessary form work complete all as specified and directed.
S&F in repairs in stainless steel wall mounted plate rack of size 780x760x240mm, thickness of sheet not less then 0.50 mm and weight not less than 7.50 kg of approved design/pattern (as approved by engr-in-chrge) with provision for keeping plate and other crockery,fixed with screw and rawl plugs etc on wall complete makes as approved by GE complete all as specified and directed.
Taking down carefully copper / aluminum point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, lamp holders, bracket, light fittings, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls, floors etc as per existing complete all as specified and directed.
S & F point wiring for one light point / fan point / bell point controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, single core stranded (multi-stranded) copper conductor cable ( FRLS) drawn into and including PVC conduit medium grade 20 mm dia with all fittings and accessories fixed on surface/ concealed (incl chase cutting in brick/stone/PCC block masonry walls for fixing conduit and plastering the external surface and matching the same with existing surface ) and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated ( green colour ) 1.5 sqmm size multi stranded copper conductor cable (FRLS) earth wire and connected to earth dolly complete all as specified and directed.
All as per item No. 81 hereinbefore but wiring for one 3 pin 5 Ampere socket outlet point on the same board, controlled by other switch complete all as specified and directed.
All as per item No. 81 hereinbefore but wiring for one 3 pin socket outlet 5 amps independent with cable 1.5 sq mm size complete all as specified and directed.
All as per item No.81 hereinbefore but wiring for one 3 pin 15 Ampere socket outlet point using 2.50 sqmm size wire (FRLS) and earth wire of PVC insulated ( green colour) 1.50 sqmm size multi stranded copper conductor cable (FRLS) on the independent board complete all as specified and directed.
S & F of switch piano flush type single pole one-way 5 Ampere complete all as specified and directed.
S & F of switch piano flush type single pole one-way 15 Ampere complete all as specified and directed.
S & F of 5 Ampere socket outlet flush type, multi purpose suitable for 2 and 3 pins (Total 5 Pins) complete all as specified and directed.
S&F of lamp holder PVC / polycorbonate type insulated body with back plate suitable for batten fitting / angle fitting complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Ampere flush type with shuttered complete all as specified and directed.
S & F ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed.
S & F LED tube light fitting 1 x 20 watts complete with all accessories including internally pre-wired and connecting up with copper flexible twisted twin core upto 1.50 m length as ordered. complete all as specified and directed.
S&F LED Bulb 12 Watt complete all as specified and directed.
Taking out old unserviceable service connection cable for replacement including supply and fixing service connection cable 1100 volts grade heavy duty PVC insulated aluminium conductor, 10 sqmm 2 core size, served with inner sheathed in service connections suspended by insulating hangers not more than 1 mtr apart inclluding 4mm suspension wire , one twin core cable flat or circular, complete all as specified and directed. Note :- 2 core 10 Sqmm size cable and 1 run of 4mm GI wire shall be measured as one unit i.e 1 RM.
S & F sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and directed.
S & F MCB single pole and neutral, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & F MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil, common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150 mm c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note:-- i) Earth lead beyond 7.5 m from electrode to earth terminal point/main switch board & GI pipe light grade 15 mm dia for protection against mechanical damage to lead shall be measured separately. ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Joshi Constructions
NK CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .