Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹28.1 L
EMD Value
₹28,080
Closing Date
16 Nov 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Electric (R&B) Division, Bhuj
Providing and Erecting Street Light on Ghuntu Road Morbi, Taluka Morbi, Dist- Morbi. (SH- Navsarjan School to Dama Dada Mandir )
357986
10/01 of 2026 2027
Open
Electrical
Works
Kutch
7 documents required · 7 mandatory
₹1,500
EXECUTIVE ENGINEER ,ELECTRICAL(ROAD AND BUILDING) DIVISION,BHUJ
₹28,080
23 Oct 2026
23 Oct 2026
23 Oct 2026
16 Nov 2026
23 Oct 2026
120 days
Name of Work:- Providing and Erecting Street Light on Ghuntu Road Morbi,
Taluka Morbi, Dist- Morbi. (SH- Navsarjan School to Dama
Rate at which the
materials will be
Sr. No. Quantity Particulars charged to the
Signature of the Contractor Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Name of Work:- Providing and Erecting Street Light on Ghuntu Road Morbi, Taluka Morbi, Dist- Morbi. (SH- Navsarjan
School to Dama Dada Mandir )
Sr. Quantities Estimated Rate
No. estimated but
may be more Description of Item.
In Figures In Words according to
1 1186 Mtr Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked 58.58 Rupees Fifty Eight
copper wires of following size to be erected as directed. And Paise Fifty
(e) 1.50 Sq.mm 3 core round PVC sheathed Eight Only
2 24 Mtr providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 115.14 Rupees One
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 Hundred Fifteen
erected in existing pipe of following size (Specifically for control panel, relays, power And Paise
switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts Fourteen Only
(f) One wire 10.00 sq. mm
3 6 Mtr Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, 295.93 Rupees Two
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 Hundred Ninety
erected in existing pipe of following size (Specifically for control panel, relays, power Five And Paise
switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts Ninety Three Only
(h) One wire 25.00 sq. mm
4 118 Ea Supplying and erecting LED street light / Flood light fittings with High power White LEDs 5581.26 Rupees Five
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and Thousand Five
corrosion free High pressure die cast aluminum housing with smooth finish powder coated and Hundred Eighty
heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened One And Paise
glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than Twenty Six Only
0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage protection.
(iv) 90 - 119 watts Cat-lll
5 3 Ea Supplying and erecting LED street light / Flood light fittings with High power White LEDs 5175.24 Rupees Five
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and Thousand One
corrosion free High pressure die cast aluminum housing with smooth finish powder coated and Hundred Seventy
heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened Five And Paise
glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than Twenty Four Only
0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage protection.
(iii) 60 - 89 watts Cat-lll
6 1 Ea Providing and erecting Approved make Four pole moulded case circuit breaker having 6790.23 Rupees Six
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. Thousand Seven
with Fixed thermal & magnetic release suitable to work on A.C. supply 50 Hz. with all internal Hundred Ninety
connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. And Paise Twenty
ICS=100% of ICU only Cat III Three Only
7 1 Ea Providing and erecting Approved make Four pole moulded case circuit breaker having 7469.25 Rupees Seven
breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. Thousand Four
with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal Hundred Sixty
connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. Nine And Paise
ICS=100% of ICU only Cat III Twenty Five Only
(10% Added For Enclosure)
8 1 Ea Providing and erecting Approved make Earth fault Relay suitable to mount with inter 5156.05 Rupees Five
connection suitable to following size of moulded case circuit breaker having CT ratio & Thousand One
MCCB rating as following along with shunt trip 220V AC. with all internal connections & Hundred Fifty Six
complete erected in existing M.S.housing.. And Paise Five
(1) 15 A -100 A , CT Ratio 1/100 Only
9 0.5 RMT Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with 1961.42 Rupees One
four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm Thousand Nine
(Rated current / cross section area) duly wrapped with colour insulating tape for phase Hundred Sixty
sequence of following current carrying capacity, erected with necessary bus bar supports One And Paise
/insulators, main cable socket to each bar, erected in existing cubical panel with necessary Forty Two Only
(A) Suitable for 100 Amp. Capacity
10 121 Ea Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and having 297.95 Rupees Two
breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Hundred Ninety
Mark Cat.III Seven And Paise
Ninety Five Only
11 4 Ea Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA 702.96 Rupees Seven
breaking capacity & confirms to IS :8828 in existing box having following capacity Hundred Two And
(b)40 Amp. Cat.III Paise Ninety Six
12 2 Ea Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing 4591.46 Rupees Four
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot Thousand Five
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner Hundred Ninety
pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with One And Paise
constant ohmic value surrounded by highly conductive compound with high charge dissipation Forty Six Only
suitable for following type of applications with chamber and heavy duty cover. (A)(approved
make OEM has to submit test certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the value of earthing
resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:-
< 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time Necessary test report must be
submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
13 2102 Mtr Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid 168.67 Rupees One
Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing Hundred Sixty
trench / pipe of following size of cables Eight And Paise
(C) 4 core 10 Sq. mm Sixty Seven Only
14 52 Mtr Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI armoured cable multistrand 229.27 Rupees Two
Aluminium conductor for 1.1 kV. to be laid on wall with necessary clamps or in existing Hundred Twenty
trench / pipe of following size of cables Nine And Paise
(B) 4 core 25 Sq. mm Twenty Seven
15 1860 Mtr Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for 74.74 Rupees Seventy
laying any size of cable or locating the fault all over the run and back filling the same and Four And Paise
making the surface as normal ground. Seventy Four Only
16 20 Mtr Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for 357.54 Rupees Three
laying any size of cable or locating the fault all over the run and back filling the same and Hundred Fifty
making the surface as normal ground. Seven And Paise
(B) If additional machinery like hammer driller or JCB use [Add] Fifty Four Only
17 30 Mtr Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding 492.88 Rupees Four
power supply by making up to following size of holes at both ends complete. Hundred Ninety
(A) Up to 100 mm bore dia Two And Paise
Eighty Eight Only
18 30 Mtr Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road 226.24 Rupees Two
crossing or on floor with necessary material in an approved manner and making the ground as Hundred Twenty
per original. Six And Paise
(F) 100 mm dia. Twenty Four Only
19 1925 Mtr Providing & laying approved make Double walled corrugated pipes (DWC) of 62.62 Rupees Sixty Two
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same And Paise Sixty
material at required depth in existing trench for laying of cable. below ground / road surface Two Only
for enclosing cable
(A)50 mm outer dia
20 2 Ea Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 38.38 Rupees Thirty
insulated armoured cable complete with out going tails, insulating tape etc for following size of Eight And Paise
cables. Thirty Eight Only
(C) 2 to 4 core 10 Sq. mm
21 2 Ea Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC 51.51 Rupees Fifty One
insulated armoured cable complete with out going tails, insulating tape etc for following size of And Paise Fifty
cables. One Only
(E) 2 to 4 core 25 Sq. mm
22 8 Ea Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size 15.15 Rupees Fifteen
evenly crimped with high pressure tool & connected to switchgear terminals with And Paise Fifteen
brass/cadmium plated nut bolts in an approved manner. Only
23 59 Ea Supply of approved make FRP Pole having following specifications: FRP Light Pole made by 17276.05 Rupees Seventeen
CNC filament winding machine using thermoset resin polyester/epoxy resin system) having Thousand Two
minimum 62% glass content. The pole should be in one piece and tapered round in shape, Hundred Seventy
having smooth finish and should be totally free from corrosion as well as non conductive & Six And Paise Five
shock proof Pole should be provided with FRP Anchor Base and it should be heavy duty, or Only
MS Material duly painted with Epoxy paint.
Pole should be flame retardant as per IS 6746. Resin used shall be UV resistance and
pigmented. A highly weather resistant polyurethane coating shall be applied to the pole after
applying suitable primer system that ensures proper adhesion of the paint. Minimum coating
thickness shall be 80 to 100 micron. Deflection of the pole shall not exceed more than 10% of
the length of pole for the given load“ Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability features of poles as per standard ANSI
C 136.20 latest version or ASTM D 4923/01 including cable termination box with necessary
accessories . The size of pole and type of installation with foundation as per manufacturer
details and site requirement are as below .
(4) Suitable for direct grouting & Double Side Arm Bracket.
[E] Overall length of 8.0 Mtr. Average Thickness: 8mm. Top/ Bottom OD Dia: 114/183 mm ±
2mm approx. approx. Weight of Pole 56 kg approx.
24 80 Ea Providing Aluminium arm bracket of having 2 sets of suitable SS304 hardware for fixing the 2569.44 Rupees Two
brackets & spread of 1.2 Mtr (Suitable for 89 to 114 mm pole top dia) Thousand Five
(A) Single arm bracket Hundred Sixty
Forty Four Only
25 19 Ea Providing Aluminium arm bracket of having 2 sets of suitable SS304 hardware for fixing the 3968.29 Rupees Three
brackets & spread of 1.2 Mtr (Suitable for 89 to 114 mm pole top dia) Thousand Nine
(B) Double arm bracket Hundred Sixty
Eight And Paise
Twenty Nine Only
26 3 Ea Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out 476.72 Rupees Four
approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for Hundred Seventy
mounting mob & hinged doors as per requirement having locking arrangements with mounting Six And Paise
clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of Seventy Two Only
following size of box.
(C)150mm x 125mm x 100mm [deep]
27 1 Ea Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out 3420.87 Rupees Three
approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for Thousand Four
mounting mob & hinged doors as per requirement having locking arrangements with mounting Hundred Twenty
clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of And Paise Eighty
following size of box. Seven Only
(I) 400mm x 300mm x 190mm [deep]
28 1 Ea Supplying & erecting IP 55 grade following size section pillar fabricated from joint less M.S. 16691.26 Rupees Sixteen
Sheet with angle iron legs made from jointless M.S. Angle with cable clamps to be buried in Thousand Six
ground to have appropriate erection to work uniform until erected with cement concrete Hundred Ninety
foundation and 45 cm high bricks work finishing with plaster etc. hinged double door internally One And Paise
supported on both side, Twenty Six Only
with internal and outside looking arrangement with look and keys in duplicate 35 x 35 x 5 mm
M.S. Angle of Two Nos. one is welded and other with nut and bolt for erecting Bakelite sheet.
Painting the Section Pillar inside and out side with three tank powder coated paint. section
pillar roof should be without joint with water leakage proof & tested as per IP 55 test &
followed by IS 2147 of
(A) 150 X 90 X 75 cm section pillar fabricated from 14 Gauge MS Sheet with angle iron legs
95 cm long made from 40 X 40 X 6 mm thick MS angle.
29 1.4 sq.mtr Supplying and erecting HYLAM sheet on existing angle iron frame.for following thickness 1927.08 Rupees One
(E) 10mm Thousand Nine
Seven And Paise
30 2 Ea Supplying & erecting approved make Digital time switch having lithium cell 6 years operative 3168.37 Rupees Three
and operate battery backup 1 channel day clock with 14 memory programme, suitable to Thousand One
operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum Hundred Sixty
& LCD display. Also comprised permanent ON/OFF switching. Programming switches & Eight And Paise
housed in fire proof thermoplastic enclosure & transparent cover erected as required with Thirty Seven Only
necessary connection erected as directed.
31 2 Ea Supplying & erecting power contactor ,AC3 duty for time switch complete erected as per 2782.55 Rupees Two
direction Cat III Thousand Seven
(D) 4 pole 440V 40 Amp. Hundred Eighty
Fifty Five Only
In Words : Rupees Twenty Eight Lakh(s) Eight Thousand Five And Paise Fifty Four Only
I/We am/are willing to carry out the work at ____________% above/below (in Figures)__________________________ percent Above / below (in
words) the estimated rates mentioned above amount of my\our tender works out as under :-
Estimated amount put to Tender Rs._________________
Deduct _____% below Rs._________________
(-)Less For Dismantle Material Rs._________________
Net Amount Rs._________________
Estimated amount put to Tender Rs. _________________
(-)Less For Dismantle Material Rs. _______________
Net Amount Rs. _________________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation regarding material,labour and other
factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other tender documents of this work
and agree to execute the same accordingly.
(Signature of the Contractor) Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered as final.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
make list guntu.pdf
notice no 10.pdf
sbd guntu.pdf
sch b guntu.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .