AE(E) FTR HQ BSF TRIPURA
FTR HQ BSF TRA
Renovation of Guard room near main gate issued on rental to SBI from electrical side at BSF campus salbagan under FTR HQ BSF Tripura
2025_BSF_888642_1
23/IGA/AE(E)/NIT/2025-26
Open Tender
Electrical Works
Percentage
30 days
FTR HQ BSF TRIPURA
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1,998
24 Dec 2025
5 Dec 2025
16 Dec 2025
5 Dec 2025
15 Dec 2025
5 Dec 2025
Laying and Jointing PVC Pipe. Heading
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano typeswitch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sq.mm.FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. A) 2X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A) 20 mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.a) 5/6 Amp. Switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.b) 3 pin 5/6 Amp. Socket outlet
Supplying and fixing metal box of 150mm X 75mm X60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections,painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X60mm deep (nominal size) on surface or in recesswith suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 Asocket outlet and 15/16 A piano type switch,connections, painting etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. b) Double pole
Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)a) 8 way , Double door
Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Supplying & fixing of 10 watt mirror light fittings and making connections etc. make Kolors/ Philips / Crompton / Havells/surya or equivalent.
Providing & fixing of 18 watt, 230 volt, 50 Hz surface slim panel LED light, making connections etc. make Kolors/ Philips / Crompton / Havells/surya or equivalent.
Supplying and fixing of 300 mm sweep, fresh air exhaust fan ( metal body) for single phase, 50 Hz, 230 volts, AC supply and making hole in existing wall to suit the size connections etc. as required. Crompton/Havells/Usha,etc.
Supplying & fixing of 40 watt LED batten light Aluminium housing on the existing wall .including connection testing etc. as required of make Kolors/Philips/Havells/ Crompton.
Supplying and fixing of 1200 mm sweep, ceiling fan for single phase, 50 Hz, 230 volts, AC supply in existing surface including connections etc. as required. Crompton/Havells/Usha,etc.
Dismentling of existing wiring including switch boards,main switches/sockets, fitments,removing of old MS boxes and making good the damaged etc as required.
Providing & fixing of 40 mm dia medium class GI pipe for protection of UG cable . Etc as required of make Jindal/Hindustan/Tata
Supplying and Laying of one number XLPE insulated and PVC sheathed aluminium armoured power cable of 1.1 KV grade of size 2x16 sqmm sq mm direct in the existing RCC/ HUME/ METAL/Wall/pipe/Open as required. make KEI/Gloster/Polycab/Havells
Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade (heavy duty) armoured UG electric cable with aluminium conductor of size 2 x 16 sq.mm. direct in ground including excavation, and refilling the trench etc as required but excluding sand cushioning, protective covering etc. as required.(Havells/KEI/finolex)
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
BOQ_934022.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .