Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.1 L+₹9.6 L (24.3%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L2 | Rejected-Finance Being L2 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
29 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO MAKARPURA BARODA 390014
WELCOME MAINTENANCE TO CERTAIN BUILDINGS AT MAKARPURA AIR FORCE STN BARODA
2020_MES_336256_2
8556/E8
Open Tender
Miscellaneous Services
Item Rate
335 days
GE AF BARODA
AS PER NIT AND TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹88,000
Yes
1 Aug 2020
4 Jun 2020
2 Jul 2020
4 Jun 2020
29 Jun 2020
15 Jun 2020
6 Jun 2020 - 10 Jun 2020
60 days
Amount
M&L for preparation of old decorated surfaces plastered or unplastered on walls including cornices pilasters by brooming down or steel wire brushing, scraping down, smoke shoot, moulds, mors and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on walls complete all as specified and directed.
All as per item No.1.00 above but three coats of white wash by complete removal of existing treatment all as specified and directed.
All as per item No 1.00 above but applying one coat of white wash on ceiling complete all as specified and directed.
All as per item No 1.00 above but three coats of white wash on ceiling by complete removal of existing treatment complete all as specified and directed.
M&L for prepration of the existing surfaces on wall/concrete surfaces thoroughly washing, rubbing down in the water, cleaning upto the entire satisfaction of the Engineer-in-Charge and apply one coat of cement base paint, colour as approved by GE complete all as specified and directed.
All as per item No 5.00 above but one coat of cement base paint on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment by scraping down completely on brick walls/ stone walls/ concrete surfaces plastered or unplastered thoroughly, rubbing down, washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of Cement Base Paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed.
All as per item No 7.00 above but two coats of cement base paint over a coat of primer on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment by scraping down washing to the entire satisfaction of Engineer-in-Charge and applying two coats of oil bound emulsion distemper (as approved by GE) and to be applied only by the authorised applicator of manufacturers (as approved by GE) complete all as specified or as directed.
All as per Item No 9.00 above but two coats of oil bound emulsion distemper on ceiling complete all as specified and directed.
M&L for prepration on the existing old decorated surfaces of walls/ concrete surfaces including scraping, rubbing down with water cleaning the surface up to the entire satisfaction of Engineer-in-Charge and applying one coat of oil bound emulsion distemper complete all as specified and directed.
All as per item No 11.00 above but one coat of oil bound distemper on ceiling.
M&L for complete removal of existing treatment on wall/ceiling surfaces by scraping down and washing with water to the satisfaction of Engineer-in-Charge and applying two coats of Oil Bound Emulsion distemper over and including applying Birla white wall care putty (as approved by GE) and to be applied only by the authorised applicater of manufacturers (as approved by GE) including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and iron surfaces over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of old plastered surfaces of wall/ ceiling and applying of JK/ Birla white putty in patch work n.exc.3sqm each patch as per Manufacturer’s specification complete all as specified and directed .
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed.
All as per item No 17.00 above but applying three coat of white wash on ceiling surfaces complete all as specified and directed.
M&L preparation of newly plastered or unplastered wall surfaces and applying two coats of oil bound emulsion distemper (as approved by GE) including applying Birla white putty as per manufacturers's specifications applied only by the authorised applicator of manufacturer (as approved by GE) Complete all as specified and directed.
All as per item No 19.00 above but applying two coat of oil bound emulsion distember on newly plaster and unplaster ceiling surfaces complete all as specified and directed.
M&L preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint over a priming coat on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed. (Colour/ shade as approved by GE).
All as per item No 21.00 above but applying two coat of cement base paint over a priming coat on newly plaster and unplaster ceiling surfaces complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick backing coat in CM 1:4 complete all as specified and directed
Dismantling of floor, hearth or wall tiling including cement mortor bedding (but not backing) removing the rubbish outside MD land complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exc 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM (1:6) complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM (1:6) complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick in CM (1:6) complete all as specified and directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square /rectangular ) matching shade with item No-28 above in vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match as in skirting over and including 10 mm thick rendering in CM 1:4 as backing coat, even and fair to receive tiles etc complete all as specified and directed.
S&F glazed ceramic coloured tiles in vertical surface 450 x300x7 mm thick set and jointed in neat cement slurry and pointed in white cement to match over and including 10mm thick rendering in cm 1 :4 as backing coat, even and fair to receive tiles etc complete all as specified and directed.
S&F glazed ceramic coloured tiles in vertical surface 300x200x7 mm thick set and jointed in neat cement slurry and pointed in white cement to match over and including 10mm thick rendering in cm 1 :4 as backing coat, even and fair to receive tiles etc complete all as specified and directed.
M&L for Vitrified ceramic tiles 9 -10 mm thick (square/ rectangular) polished (double charged), area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 20mm thcik screed bed in CM 1:6 complete all as specified and directed.
M&L for Vitrified ceramic tiles 9-10 mm thick (square/ rectangular) polished (double charged), as in skirting, dado etc with matching to item No 32.00 above set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10mm thcik screed bed in CM 1:4 complete all as specified and directed.
Taking down cement plaster of any description in any position, including racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surface, finishing surface even & smooth without using extra cement complete all as specified and directed.
All as per item No 35.00 above but as in patches n.exc 3 Sqm complete all as specified and directed.
M&L for rendering in two layers (i.e) first layer of 10mm thick in CM 1:6 and second layer of 5mm thick including WPC @3% by weight of cement in CM 1:4, on fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. Note :- WPC will be measured and paid separately under the relevant item.
All as per item No 37.00 above but as in patches not exc 3 Sqm complete.
M&L rendering 10mm thick in CM (1:3) on concrete surface of ceiling, finishing surface even & smooth without using extra cement complete all as specified and directed.
All as per item No 39.00 above but as in patches n.exc 3 Sqm complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
M&L filling surface cracks not exc. 5mm to 7mm wide with "Dr Fixit" cracks X power or equivalent polymer modified cracks filler all as per manufacturer's instructions complete all as specified and directed.
Making V shaped grooves of 25 x 25mm on wall/concrete surfaces complete all as specified and directed.
S&F in repairs health faucets CP of Parryware/ CERA/ Hindware/ equivalent connected for EWC complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed to aluminium windows shutters incl aluminium beading etc complete all as specified and directed.
S&F in repair vitreous china wash basin, white flat back size 550 x 400 mm including waste pipe,waste coupling,PVC connection 450 mm long, brackets etc complete all as specified and directed.
S&F in repair vitreous china wash basin, white flat back, size 550 x 400 mm with pedestal including waste pipe,waste coupling,PVC connection 450 mm long, brackets etc complete all as specified and directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts, and flush pipe) complete all as specified and directed.
S&F in repairs vitreous china squatting pan water closet ‘orrisa’ pan size 580x440mm incl. Integral foot rest including cement concrete bedding etc complete all as specified and directed.
S&F in repair 15mm dia Bib taps fancy type CP, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15mm dia Bib taps CP, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15mm dia Bib taps fancy type CP long body shank, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm dia Stop valves, cast copper alloy fancy type CP, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 15mm dia Stop valves, cast copper alloy fancy type CP with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 15mm dia angle Stop cock, cast copper alloy fancy type CP, screwed down, high pressure, with crutch or butterfly handle, screwed one end for iron pipe and other end for PVC connection pipe complete all as specified.
Demolition of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Cutting chases in brick walls, for concealed water tubing, etc, and making good in CM 1:3, cutting exc 10 cm and n.exc 20cm girth complete all as specified and directed.
S&F in repair water closet seat black/white closed pattern with flat bottom and cover and MS chrominium plated or aluminium hinging device complete all as specified and directed.
S&F in repair 10ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks exc 250 and n.exc 500 ltr capacity and from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks exc 500 and n.exc 1000 ltr capacity and from mouths of circulating pipes, etc complete all as specified and directed.
Cleaning and removing all scale and dirt, etc, from tanks exc 1000 and n.exc 2000 ltr capacity and from mouths of circulating pipes, etc complete all as specified and directed.
S&F in repairs Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one all as specified in SSR Part I complete all as specified and directed.
S&F in repairs Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one all as specified in SSR Part I complete all as specified and directed.
S&F in repairs Rotational moulded polyethylene water storage tanks 2000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one all as specified in SSR Part I complete all as specified and directed.
S&F in repair 15mm size Ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 20mm size Ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 25mm size Ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair cover for PVC water storage tank of 500/1000/2000 ltr capacity with pvc nut and bolt and fixing arrangement complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings complete all as specified and directed.
M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L Brickwork with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement Concrete (Reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L Plain cement concrete type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) as in 25mm thick sub base of flooring including finishing surfaces rough to receive floor finishes, complete all as specified and as directed.
M&L for RCC type B-1 1:2:4 (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC type B-1 1:2:4 (using 20mm graded stone aggregate) as in Chajjas complete all as specified and directed.
S&F in repair cast iron floor trap 75 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1, (1:2:4) complete all as specified and directed.
S&F in repair 50mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair 50mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair name plate made out of acrylic sheet (area n exc 0.15 sqm each plate) with reflective tape and fixed to wall with suitable ss screws in OMQs etc all as spd and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including mixing water proofing compound @3% by wt of cement finished even and smooth (without using exra cement) in sunken portion,making jambs,heads etc. including taking down of existing plaster complete all as specified and directed. Note :- WPC will be measured and paid separately under the relevant item.
M & L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg/sqm including cleaning surfaces in sunken portion complete all as specified and directed.
M&L for PCC in 1:5:10 type E2 (using 40mm graded agg) as in foundation, filling and mass concrete including mixing water proofing compound @3% by wt of cement complete all as specified and as directed. Note :- WPC will be measured and paid separately under the relevant item.
Taking down Chowkats or frames with shutter (without taking off shutter from the frame) not exc. 1.5 sqm each and removing complete all as specified and directed.
Taking down Chowkats or frames with shutter (without taking off shutter from the frame) exc. 1.5 sq. m and n.exc 4.00 sqm each and removing complete all as specified and directed.
M&L Anodised aluminium frames and shutters powder coated for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
M&L in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed.
S&F 5mm thick tinted glass fixed with and incl necessary rubber gasket and aluminium beading complete all as specified and directed. Note :- Cost of rubber gasket and aluminium beading are deemed to be included in the rate quoted.
S&F 4mm thick Sheet glass, ordinary Quality and glazing with oil putty or wooden beads in square exc 0.5 sq. m in each pane complete all as specified and directed.
S&F 4mm thick Figured glass, pin head type and glazing with oil putty or wooden beads in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal (steel or aluminium) frames, frames incl punching or drilling out old glazing pins/spring clips/ beading/ gasket and providing and fixing new ones complete all as specified and directed.
S&F in repair Mortice lock stainless steel vertical type size 100mm 2 levers fixed to wooden or Aluminium door shutters complete all as specified and directed.
S&F aluminium lock for aluminium sliding windows complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium beads to aluminium shutters complete all as specified and directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples or wooden beads complete all as specified and directed.
M&L for Framed work such as grills, gratings, angle iron frames for doors etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description n exc 1 sqm each complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 2 sqm each complete all as specified and directed.
S&F in repair 100 mm size Aluminium anodised tower bolts of extruded section including screws complete all as specified and directed.
S&F in repair 150 mm Aluminium anodised tower bolts of extruded section including screws complete all as specified and directed.
S&F in repair 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F in repair 75mm size butt hinges stainless steel medium weight complete all as specified and directed.
S&F in repair 100mm size butt hinges stainless steel medium weight complete all as specified and directed.
S&F in repair continuous piano hinges mild steel bright finish or electro galvanised width of flap 30mm complete all as specified and directed.
S&F in repair 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repair 100mm size Aluminium handles, cast type, anodized complete all as specified and directed.
S&F in repair 150mm size Aluminium handles, cast type, anodized complete all as specified and directed.
S&F in repair 100mm Aluminium anodised Hasp and staple, safety type with mild steel hinge pin incl bolts to hinge plate and fixed with screws complete all as specified and directed.
M&L fair cutting on brick work any description exc 10cm width or girth from external wall and repair of joints with CM 1:1 without distrubing internal floor/tiles and making good in CM 1:3 with and including WPC, checking of leakage after one week, complete all as specified and directed.
S&F 15mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down old tubing complete all as specified and directed.
S&F 20mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down old tubing complete all as specified and directed.
S&F in repair sinks with drain board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repairs stainless steel plate rack of size not less than 900mm x900mm complete all as specified and directed. (Make- Pooja/Nirali/Kingston/Prayag)
S & F in repairs stainless steel plate rack of size not less than 750mmx750mm complete all as specified and directed. (Make- Pooja/Nirali/Kingston/Prayag)
S&F in repair 32mm size Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repair 40mm size Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F in repair SS Tubular towel rail 450mm long incl fixing arrangements complete all as specified and directed.
S&F in rapair PVC Connection 15mm size 450mm long complete all as specified and directed.
S&F in rapair PVC Connection 15mm size 600mm long complete all as specified and directed.
S&F in repair Shelf of PTMT fixed with and including CP screws and wooden/ plastic cleats (Minimum wt 300 gms) complete all as specified and directed.
S&F in repair stainless steel bright finish round shape 100mm size fixed grating over floor trap in white or gray cement to match with existing floor complete all as specified and directed.
All as per item No 137.00 above but 125mm size with access hole for inserting waste pipe etc complete all as specified and directed.
S&F in repair shower rose brass chromium plated 125mm size with swivel arm etc complete all as specified and directed.
S&F in repair 20mm dia aluminium anodised tubular curtain rod with powder coating finishing, complete all as specified and directed.
S&F in repair brackets for curtain rod ornamental fancy type suitable for fixing matching with curtain rod complete with fixing screws complete all as specified and directed.
S&F in repair 25mm dia Stainless steel tubular curtain rod fixed to brackets . Complete all as specified and directed.
S&F in repair Fancy type brackets suitable for fixing of 25mm dia Stainless steel tubular curtain rod complete with fixing screws of stainless steel complete all as specified and directed.
S&F in repair stainless steel Jet spray for EWC complete all as specified and directed.
M&L, Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns. hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L, Mild steel TMT bars 5mm dia and over upto 10mm dia as in sturrups, spacers and binders etc, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns. hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Welding in repair n exc 2.5cm in length and thickness of metal to be welded exc 6mm and n exc 9mm complete all as specified and directed.
Welding in repair exc 2.5cm and n exc 5cm in length and thickness of metal to be welded exc 6mm and n exc 9mm complete all as specified and directed.
S&F in repairs single mirror bathroom cabinet moulded body and frame (made of strong and fine quality ABS) with hanged door (Size 16"x12") white in colour make as approved by GE fixed to wall with appropriate rawl plugs complete all as specified and directed.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair Sheet glass bath corner shelf assembly consisting of 5.5mm thick sheet glass shelf having radius 20 to 25 cm with chromium plated bracket guard and railing complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F in repair 12mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work such as door shutters etc complete all as specified and directed.
S&F in repair 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S&F in repair stainless steel Peg set of six including fixing screws etc complete all as specified and directed.
Labour only for checking serviceability of Internal electric wiring system from main distribution DB to end point where ever required including fixing the loose wire and fixing PVC pipe /casing caping to its original position with necessary screws, clips etc and making good complete all as specified and directed. Note : Rectification includes for cost of PVC casing caping ,PVC copper cable and connected insulaion tape etc up to 0.5 mtr in the quoted rate. Bldg /location directed by AGE E/M and contractor has no claim on this account.
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power) complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical, fan regulators, light or power sockets etc removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed (FRLS) multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface of walls/ceiling by means of PVC sleeves Dash fastners and cadmium plated screws all as per ISI including sunk type boxes suitable for mounting modular fitting like switches, socketes fan regulators with 3 mm thick phenolic Laminated sheet top covers concealed in walls etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable as earth continuity conductor to common earth dolly complete all as specified and directed for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board
One bell point controlled by one way switch
One light point controlled by two, two way switches
All as per item No 159.00 above but wiring with 2.5 sqmm (FRLS) multistranded copper conductor unsheathed and 1.5 sqmm (FRLS) copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
M&L for drawing in existing conduit system of wiring concealed point wiring complete with multistranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code drawing in existing conduit system of wiring, complete and providing top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories on existing sunk type pressed terminal boxes of available size suitable for mounting modular switches including 1.5 sqmm size signle core multi stranded copper conductor solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified and directed for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One bell point controlled by one way switches
All as per item No 161.00 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 1.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
Note for above item 159 to 162 The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE (E/M). Delay in any work more than of 3 days after allocation will invite recovery at double the quoted rate. Contractor shall depute a team of electrician and helper on daily basis at Makarpura to carry out maintenance within stipulated time.
Supplying & fix modular switch, single pole one way 6 Amps, 230 volts AC circuit complete all as specified & directed.
Supplying & fix modular switch, single pole one way 16 Amps, 230 volts AC circuit complete all as specified & directed.
S&F socket only 6 Amps Modular type 240 Volt complete all as specified and directed. Make: Havells (Crabtree, Athena- ACAKPXW065), ROMA, Legrand or equivalent make approved by GE.
S&F socket only 6/16 Amps 5Pin Modular type 240 Volt complete all as specified and directed. Make: Havells(Crabtree, Athena- ACAKCXW163), ROMA, Legrand or equivalent make approved by GE.
S & F switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed.
S&F Fan Regulator 5 step Modular type 240 Volts complete all as specified and directed. Make: Havells(Crabtree, Athena- ACARFHW005), ROMA, Legrand equivalent make approved by GE.
Supply and fixing in repir lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified and directed.
Supply and fixing bell push, 6 Amps , flush type, 230/250V, 50 Hz supply, complete all as specified and directed.
Supply and fixing in repair switch piano 5 Amps, flush type, single pole, one way, 230/250 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing in repir switch piano 15 Amps flush type one way 230/250 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing in repir socket outlet 3 pin 6 amps, 230/250 volt. flush type, ISI Marked complete all as specified and directed.
Supply and fixing in repir socket outlet 2 in 1, 6 pin 5 /16 Amp, 230/250 volt and multi pin flush type, complete all as specified and directed.
Supply and fixing in repair ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed.
Supply and fixing in repairs Bulb LED 15 Watt suiable for holder complete all as specified and directed.
Taking down Ceiling/Exhaust fan, sealing cable end, dismantling blades and removing fan and blades from site for servicing and refixing after servicing including replacing check nuts, quarter pins as required at site and connecting with wire and testing operation complete all as specified and directed. Note: Charges of painting will be measured and paid seperately under respective items.
M&L for preparation old painted surface of Ceiling/Exhaust fans of any description by cleaning dust and apply one coat approved synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc complete all as specified and directed.
M & L for sub main wiring using two runs of single core 6 Sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit with accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed copper conductor cable including taking down old unservicable sub main wiring any type complete all as specified and directed. Note : Two runs of single core 6sqmm cable, one run of 4sqmm cable and PVC casing caping/counduit shall be measured as a one length.
M & L for sub main wiring using two runs of single core 4 Sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit with accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 2.5 Sqmm earth wire, PVC insulated & unsheathed copper conductor cable including taking down old unservicable sub main wiring any type complete all as specified and directed. Note : Two runs of single core 4sqmm cable, one run of 2.5sqmm cable and PVC casing caping/conduit shall be measured as a one length.
M & L for sub main wiring using two runs of single core 2.5 Sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit with accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 1.5 Sqmm earth wire, PVC insulated & unsheathed copper conductor cable including taking down old unservicable sub main wiring any type complete all as specified and directed. Note : Two runs of single core 2.5sqmm cable, One run of 1.5sqmm cable and PVC casing caping/conduit shall be measured as a one length.
Taking down carefully UNSV main switch and DB's including MCBs of of any size make, type and capacity and depositing at site complete all as specified and directed.
S & F MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard copper bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed.
S & F MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard copper bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified.
Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber with 50mm thick RCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia unto 7.5 from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata complete all as specified and directed by Engr-in-Charge including demolition of old unsv existing earth pit and removing from site . Note : Galvanise earth lead wire exceeding 7.5mtr shall be measured and paid sepraterly.
Supply and fix galvanised iron wire 4 mm dia buried in ground or on wall complete all as specified and directed.
Supply and fix in repairs MCB double pole 40 to 63 amps 415 Volts B series complete all as specified and directed.
Supply and fix in repairs MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity B seriesfixed in DB's complete all as specified and directed.
Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity B series fixed in DB's complete all as specified and directed.
Supply and fixing in repairs indoor decorative ultra brigt polycarbonate LED retrofit tube light with very high efficincy of 18 Watt suitable for channel housing fitting slim LED batten including taking down old unserviceable complete all as specified and directed.
Supply and fixing in repairs indoor decorative channel housing fitting slim LED batten 10 Watt (Mirror Light) with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete all as specified and directed.
Supply and fix in repairs bell ding dong type, one way, dual tone Aesthetics 240 volts, AC, ISI marked complete all as specified and directed.
Supply and fix in repairs geyser of 25 Ltr capacity ,5 star rating including fixing bolts/fastnernecessary cement work making good the disturbed surface .water connection, electrical connection with three core PVC insuklated copper conductor cable 40/0.0076 size complete all as specified and directed.
M/L in repairs MS box 1.6 mm thick of 4" x 4" ( 100 mm x 100mm ) size complete with 4 Nos brass screw with washer and 3 mm thick hylam sheet , embeding the MS box into the wall properly , necessary cementing and making good disturbed surface of wall with plastering and white washing , cutting opening on the hylam sheet , refixing old but serviceable switch , socket regulator as per the existing at site . Note : Switch ,socket, regulator which found unservicable shall be replaced by new one and shall be measured and paid seperatelly under respective item of the schedule .
All as per item No 194.00 above but of size 150 mm x150 mm size complete all as specified and directed.
All as per item No 194.00 above but of size 200mm x 250 mm size complete all as specified and directed.
All as per item No 194.00 above but of size 200 mm x 300 mm size complete all as specified and directed.
Supply and fix in repair MCCB three pole 100 amps 415 Volts breaking capacity 25 KA as per IEC 60947-2 complete all as specified and directed.
Supply and fix in repair MCB four pole 63 amps 415 Volts B series complete all as specified and directed. .
Chanda Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .