Assistant Executive Engineer
O/o Assistant Executive Engineer , PWD Electrical Sub division, kollam
DEPOSIT Judicial Magistrate of the 1st ClassII Kottarakkara Supply and installation of inverter General Electrical Work
2026_PWD_828331_2
PWD/BLDG/TR/20908/2022
Open Tender
Electrical Works
Percentage
60 days
Kottarakkara
Please refer tender document
9 documents required · 9 mandatory
₹555
₹2,648
29 Jan 2026
29 Jan 2026
7 Feb 2026
29 Jan 2026
5 Feb 2026
29 Jan 2026
Electrification
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD165840/2022-2023:Supplying and clamping the following sizes of corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI / painted MS saddles spacing not exceeding 60 cms on surface including making good the damages, colour washing etc. as required. 20 mm dia
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
2.24.2:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
OD183836/2025-2026:Supply, conveyance, installation, testing and commissioning of 2 KVA Home UPS working by 24 Volt DC supply ( 2Nos 12V 150AH Tubular Battery) with battery charging unit with indications ,input voltage 150-270V AC supply , Output voltage 230V +/-3%, 50 Hz +/- 1% pure sine wave and Short circuit,over/under voltage,surge & spike protections including giving connection etc (Hykon/ Numeric/Supra/luminous) & SITC of 2Nos 12V 150AH fully charged Lead acid Tubular Battery with terminal leads for the existing 2 KVA inverter unit with Battery Stand for accommodating Inverter and Batteries (Hykon / luminous / Numeric, /Excide) .--
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.07 MB
AFFIDAVIT.pdf
Tender Documents • 0.03 MB
PRILIMI.pdf
Tender Documents • 0.64 MB
E.pdf
Tender Documents • 0.01 MB
I.pdf
Tender Documents • 0.02 MB
SP.pdf
Tender Documents • 0.36 MB
T.pdf
Tender Documents • 0.11 MB
BOQ_1397550.xls
BOQ • 0.32 MB
S.pdf
Tender Documents • 1.83 MB
L.pdf
Tender Documents • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .