Tender Value
₹50,809
EMD Value
₹1,270
Closing Date
14 May 2026, 3:00 pmClosed
Assistant Executive Engineer
O/o Assistant Executive Engineer PWD ELECTRICAL SUB DIVISION KOLLAM
GENERAL Construction of new toilet block and Digital computer Room to court complex Sasthamcotta General Electrical Work
2026_PWD_837378_3
PWD/BLDG/TR/1973/2026_6_1_1/1
Open Tender
Electrical Works
Percentage
120 days
Sasthamcotta
Please refer tender document
9 documents required · 9 mandatory
₹555
₹1,270
Yes
6 May 2026
6 May 2026
16 May 2026
6 May 2026
14 May 2026
6 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group B | - | point | 1,360.99 | - |
| 1.002 | OD300050/2025-2026:Supply and fixing LED Bulk head with IP65 protection, suitable for surface and wall mounting application including giving connection etc as required ( Philips make WT140W LED7S CW PSU S1 PC or equivalent Make) - | - | each | 982.47 | - |
| 1.003 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. | - | each | 519.1 | - |
| 1.004 | OD300062/2025-2026:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C- | - | each | 2,156.04 | - |
| 1.005 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | - | each | 187.04 | - |
| 1.006 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | - | each | 424.29 | - |
| 1.007 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | - | metre | 109.53 | - |
| 1.008 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | - | metre | 158.06 | - |
| 1.009 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | - | metre | 147.76 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.07 MB
E.pdf
Tender Documents • 0.01 MB
AFFIDAVIT.pdf
Tender Documents • 0.03 MB
PRILIMI.pdf
Tender Documents • 0.64 MB
IP.pdf
Tender Documents • 0.02 MB
SP.pdf
Tender Documents • 0.36 MB
L.pdf
Tender Documents • 0.11 MB
T.pdf
Tender Documents • 0.10 MB
BOQ_1435289.xls
BOQ • 0.34 MB
SBD.pdf
Tender Documents • 1.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .