Loading…
Loading…
Tender ID
Tender Value
₹2.9 L
EMD Value
₹5,900
Closing Date
28 Apr 2026, 11:00 amClosed
EXECUTIVE ENGINEER
ELECTRICAL DIVISION HPPWD PALAMPUR
Repair and maintenance of split type air conditioning units (LG)make and window type AC (Voltas make)installed in OPD area in 500 bedded hospital at Dr. RPGMC Kangra at Tanda
2026_PWD_134764_3
Electrical Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Tanda
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
₹5,900
21 Apr 2026
21 Apr 2026
28 Apr 2026
21 Apr 2026
28 Apr 2026
21 Apr 2026
Repair, servicing & comprehensive Maintenance of Split type Air-Conditioning Units LG Make having following capacity including maintenance of voltage stabilizer and all other accessories with sleeves, drain pipe, insulation and battens etc. with servicing, cleaning the filters in routine intervels i.e. 04 Nos. services, when required throughout the year excluding replacement of the compressor of A.C. units which are beyond repair. The repair and maintenance has been done as per instructions and directions to the best satisfaction of Engineer-in-charge.
Split type A.C. units 2 TR capacity
Repair, servicing & comprehensive Maintenance of Window Air-Conditioning Units Voltas Make having following capacity i.e. rackout of these units for servicing including washing of filters in routine intervels i.e. 04 Nos. services throughout a year. with the time period of three months and reinstallation of these units after necessary PCB testing, fan motor, swing motor, drain pipe, refrigerant pressure testing, testing of temperature senser and all other wiring including stabilizer wiring etc. and emergency call attending services during the any type of fault in air-conditioning units as required complete in all respects and to the best satisfaction of Engineer-in-charge.
Window type A.C. units 1.5 T.R capacity
Replenishment/charging of refrigerant R-22/32 (Gas) in split air-conditioning units as required complete in all respects as per the direction and to the best satisfaction of Engineer-in-charge.
Supplying and fixing of following accessories suitable for 1.5/2 Ton capacity split type air-conditioning units as required complete in all respects and as per directions of Engineer-in-charge.
Providing & fixing of extra copper tubes for refrigerant and condensate (1/4" x 1/2") for 1.5 T.R. split type A.C. units and wiring with suitable size of HRFRLS copper conductor single core cables, including the cost of insulation etc. as required complete in all respects.
Supplying, installation, testing and commissioning of compressor of following capacity suitable for required size/ capacity air-conditioning units complete in all respects and to the best satisfaction in Engineer-in-charge.
Compressor for 2 Ton A.C. unit
Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Acceptable Make
Copper Wire/Telephone Cable/UTP cable/ TV Cable:Finolex/KEI/ Polycab/ RR Kabel/ Havells/ Grandlay (duly ISI Marked)
Aluminium and copper XLPE Power Cables Armoured/Unarmoured:Finolex/KEI/ Polycab/ RR Kabel/ Havells/ Grandlay (duly ISI Marked)
Cat 6/ 6A Cable:Molex/ Digilink/ Schneider/ Belden/ Legrand
Modular Switch, Socket, Fan regulator, RJ-45, Cable TV socket, Data outlet socket, GI boxes etc. and accessories:Legrand : ARTEOR Honeywell : ORNA Panasonic : EUROPA Schinedier : ZENCELO
PVC Conduit with accessories:Finolex/ Supreme/ BEC/ NIC/ Polycab/ AKG (All shall be Min. 2mm thick and ISI marked)
MS Conduit with accessories:AKG/ NIC/ BEC/ RMCON (Note: The accessories shall be same that of conduit pipe and will comply to IS/ 4768 part 2 2003)
GI Pipe (for pipe pole and other items):Tata/ Jindal/ SAIL (All shall be ISI marked)
OFC cable and accessories:Belden/ D Link/ Tyco
Gland:Comet/ Dowells
HDPE/ DWC pipe:REX/ Duraline/ Duraplast/ Triputi
MCB/MCB DB/ Isolator/ RCCB/ Industrial Socket
MCCBs/ RCCBs/4 Pole Power contractor /Change Over:Legrand /Siemens/ Schneider/ L&T /ABB
600 mm LED mirror light:L&T D Sine/ Schneider Compact NSX/ Legrand DPX3/ Siemens 2 VL/ ABB
LED bulk head fitting:Phillips/ Wipro/ Trilux/ Havells/ LT/ Panasonic
LED downlighter:Phillips/ Wipro/ LT/ Regent/ Panasonic
36 watt 2'x2' panel light:Phillips/ Wipro/ LT/ Regent/ Panasonic
36 watt LED batten light:Phillips/ Wipro/ LT/ Regent/ Panasonic
LED bed side light
Decorative wall light with E27 holder:Phillips/ Trilux/ Regent/ LT/ Lustre/ Panasonic/ wipro
250/200 mm fresh air fan:USHA/ Khaitan/ Crompton/ Almonard
300 mm sweep heavy duty exhaust fan:Usha/ Almonard/ Havells/ Orient/Bajaj/ Crompton
3 /25 Ltrs. Geysers::Recold/ Bajaj/ Havells/ Crompton/ AO Smith/ Venus
2 compartment energy meter board panel feeder pillar:Kalyani Switch Gear/ Power Associates/ Pristine/ Milestone/ ADLEC/ Tricolite/ ASPL/ CMKL
Ceiling fan:Usha/ Almonard/ Havells/ Orient/Bajaj/ Crompton
Or as per given against item or work and as per approval of Engineer-in-Charge
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
AC.pdf
Tender Documents • 3.91 MB
BOQ_199449.xls
BOQ • 0.31 MB
DECLARATION.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .