Executive Engineer STD, PDD ,Kargil
2nd Floor Hotel Yak Land Baroo Kargil
Annual maintenance Contract of O6 No. 66 by 11 KV Stations, 93 KM 66 KV transmission line and loading-unloading of materials at Store and other allied works for the Year 2023-24 and 2024-25 for Sub Transmission Division Kargil
2023_PDNRE_11365_1
e-NIT No. STDK-15 of 10-2023
Open Tender
AMC/ Maintenance Contracts
Works
720 days
Kargil
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Executive Engineer STD Kargil
₹1.4 L
27 Oct 2023
6 Oct 2023
19 Oct 2023
7 Oct 2023
17 Oct 2023
11 Oct 2023
9 Oct 2023 - 10 Oct 2023
Maintenance/ Testing / Replacement of 11KV Switchgear
Dismantling, cleaning, greasing and assembling of hand pullout system, racking mechanism of chassis and position indicators. Alignment of breaker in panel for smooth racking-in/ racking-out operation shall be done and adjustments shall be done if required.
Cleaning of 11KV panels by way of vacuum cleaner/air blower & Cleaning and tightness checking of CTs, PTS and control wiring connections in terminal blocks.
Replacement of faulty relay of 11KV Board after carrying out control ckt. checking.
Cleaning of contacts, checking of vacuum interrupter, tripping coils, closing coils and replacement if required & checking of mechanical tripping mechanism and adjustment if required.
Maintenance of SF6 Breakers
Inspection and checking of SF6 leakages, refilling of SF6 gas, checking of SF6 density monitor and pressure setting replacement if required. Checking of close/trip mechanism from remote, local and manual operation and associated indicators. Checking of protection and interlock system complete job. Checking of spring charging mechanism and and associated indicators.
Checking of door ceiling gaskets and replacement if any, Checking of space heater and illumination system. Checking of tightening of all cable termination in TB and control cable dressing, tightening of cable glands and lugs and replacement if required. Checking tightness of foundation bolts
Maintenance of 66 KV CTs and PTs
Routine maintenance of CTs, PTs, oil level monitor and topping of oil if required. Measurement of CT, PT secondary resistance, ratio test, Magnetization characteristics and checking of primary connection strips. Cleaning of dusts and visual inspection of any cracks in insulators of CTs, PTs. Checking tightness of foundation and equipment bolts. Cleaning of marshalling boxes, checking of healthiness of gaskets, junction boxes, carrying out DGA and testing of other parameters of oil.
Maintenance of 66/11 KV, 6.3 MVA Power Transformer
Complete cleaning of Transformer, Marshalling Box, and Control Panel, tightening of bolts and replacement of gaskets if required. Checking oil level in bushings and topping when required. Topping of oil in conservator and OLTC if required. Checking of OLTC mechanism, pressure relief device, Buchholz relays and respective protection system
Checking of Winding Resistance / IR, PI, BDV / DGA of Oil. Checking of alarm/trip circuits, release of air from different points shall be done, if reqd. Checking the healthiness of Control Circuit Connections and various Logics, if reqd. Calibration of OTI / WTI of transformer, shall be done if reqd. Periodic replacement of breather.
Maintenance of 66KV Isolators with earth blade
Cleaning of isolator contacts, greasing of contacts, replacement of damaged contacts. Checking opening/ closing mechanism both manual and electrical, adjustment of switches, link rods and livers required if any. Checking of isolators alignment for proper fitting of contacts and adjustment required if any. Checking of earthing strips and Tightening of nuts and bolts
Maintenance of Battery Sets & Battery Chargers .
Cleaning of battery surface, joints, all inter cell connectors and tightness checking of all joints. Application of petroleum jelly / Battery Terminal Protector at all joints, if reqd. Checking the Specific Gravity, Voltage and Electrolyte Level of each cell Topping up of cells with electrolyte, wherever necessary. Checking the battery vent plugs and replacing wherever necessary. Cleaning of Battery Charger panels internally and externally. Checking of all electrical connections of charger panels for tightness and cleaning. Replacement of any defective battery cells, after proper charging, if necessary. Periodic Boost Charging of Battery Banks, as and when required.
Laying/fixing of Power and Control Cables.
Laying fixing of Power Cable of size up to 300 sq. mm on surface / in the existing masonry/ duct if required.
Laying fixing of Power Cable of size up to 185 sq. mm on surface / in the existing masonry/ duct if required.
Laying and fixing of One Control Cable of size up to 2.5 sq. mm and any no. of Cores on surface / in the existing masonry duct if required
Removal of false flooring / tray cover / conduits, etc placing them back after job
Fixing of power cable kits indoor and outdoor type up to 300 sq./185 sq. mm if required.
Replacement/repair of 11KV GO sets if required
Checking of Switch yard lightning and replacement of any defective parts complete job.
Repair/ replacement of trench cover if required
Laying and fixing of One Control Cable of size up to 2.5 sq. mm and any no. of Cores on surface / in the existing masonry duct if required
Urgent/ breakdown maintenance of switch yard equipments.
Replacements of CTs single pole by way of modification of their mounting bases if required. Carriage from divisional store to site of work and installation/ commissioning on existing structure complete job. Dismantling of the damage one and return to the store. (labor charge) • Replacement of CT Single pole
Replacement of SF6 Breaker single pole by way of modification of their mounting bases if required. Carriage from divisional store to site of work and installation/ commissioning on existing structure complete job. Dismantling of the damage one and return to the store. (labor charge)
Replacement of Surge isolater single pole pole by way of modification of their mounting bases if required. Carriage from divisional store to site of work and installation/ commissioning on existing structure complete job. Dismantling of the damage one and return to the store. (labor charge)
Repair/ replacement of earthing switch blades and its contacts including its alignment, link/ lever movement adjustment, tightening of nuts and bolts complete job. Dismantling of the damage one and return to the store. (labor charge)
Routine/urgent/ breakdown maintenance of 66KV Transmission Line.
Foundation back filling / soil removal.
Replacement of missing/damaged tower component and danger/number/phase/Circuit plate/ACD
Trimming/cutting of trees.
Replacement of damaged/ broken 11KV disc insulators in normal areas.(Single string)
Replacement of damaged/ broken 11KV disc insulators in Hilly/tough terrain areas.
Providing of mid span joints in panther conductor in case of cutting/ snapping of conductor and restringing of conductor.
Repair/ replacement of damaged jumpers of 66KV line.
Repair/replacement of dead ends by way of dismantling of conductor and restringing
Repair/providing of revetment wall if required
Patrolling of 66KV Transmission line when required
Allied items for power transformer,11KV & 66 KV Switchgear & other equipment maintenance
Installation of SF6 circuit breaker
Installation of 66 kv isolator
Installation of 66kv C&R Panel
Installation of 11 kv Vaccum circuit breaker
Installation of 66kv reactor
Installation of 11 KV GO set
Stringing of Panther Conductor
Installation of 6.3 MVA transformer
Installation of 10 MVA transformer
Fixing of Disc sets
Errection of 9 mt long pole
Replacement of defective energy meters
Relay settings,cordination and testing on 66 KV and 11 KV levels of a receiving station
Energy meter calibration at 66 KV and 11 KV level of a receiving station
Dweeding/removing of unwanted grass and other items from a receiving station
Watering of earthing pits of a receiving station
Minor repairs of bathroom,kitchen including drainage pipes and sinks at a receiving station
Emptying of septic tanks of control room toilets of a receiving station
Power and control cable dressing of a receiving station
Cleaning of control room ,switch yards,transformer by removing dirt,sand,soil accumulated due to windstorms etc…
Chemical earthing complete job
Testing of power transformer complete using CMRI kit
Replacement of faulty cts of 11KV Board after carrying out control ckt. checking.
Replacement of faulty pts of 11KV Board after carrying out control ckt. checking.
Replacement of faulty burn out MCB of 11KV Board after carrying out control ckt. checking.
Replacement of burn out fuses of 11KV Board after carrying out control ckt. checking.
Replacements of PTs single pole by way of modification of their mounting bases if required. Carriage from divisional store to site of work and installation/ commissioning on existing structure complete job. Dismantling of the damage one and return to the store. (labor charge) • Replacement of PT Single pole
Replacements of SA single pole by way of modification of their mounting bases if required. Carriage from divisional store to site of work and installation/ commissioning on existing structure complete job. Dismantling of the damage one and return to the store. (labor charge) • Replacement of SA Single pole
Replacement of damaged 66 kv tower A,B & C which include carriage of tower material from store and errection of the same including replacement of damaged conductor/insulators by fresh to be supplied by store (complete job)
Transportation of 10/6.3 MVA Transformer from site to workshop /store
welding of bolts of tower upto 2 stages to avoid stealing of nuts and bolts
Tightening of jumpers in 66 kv towers of type A,B &C to avoid flashover due to loose connections
Tightening of 11 kv jumpers
Filtration of oil /testing at divisional stores per barrel
Loading,unloading of power cables of sizes,panther conductor,earth wire
Loading,unloading of transformer of different capacities
Loading,unloading of station equipments like batteries,chargers,cts,pts,isolators,link sets,g.o sets,do.fuse sets,insulators,kits,dead end fittings,nuts and bolts,clamps etc
M/S ZARDEEP ENTERPRISES
M/S MOHD TAHIR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .