| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹15.6 L+₹63,876.25 (4.27%)Rejected-Finance 0 NEAR SATYANARAYAN SOCIETY GAYATRI MANDIR ROAD 0 BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹16.9 L+₹2.0 L (13.0%)Rejected-Finance BHUJ NAKHTRANA HIGHWAY ROAD AT POST SHUKPAR NAVAVAS BHUJ KUTCHH 370040 GUJ | KACHCHH | GUJARAT | 370040 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹17.3 L+₹2.4 L (15.8%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹17.6 L+₹2.6 L (17.4%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹16.4 L
EMD Value
₹32,860
Closing Date
26 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
PROVISION OF CERTAIN CAP/MR/MW WORKS UNDER AGE BR-(I) (II) AND AGE (E/M) AT AF STATION BHUJ
2022_MES_568736_2
8625/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) BHUJ
₹32,860
Yes
4 Mar 2023
9 Jan 2023
28 Jan 2023
9 Jan 2023
26 Jan 2023
14 Jan 2023
10 Jan 2023 - 11 Jan 2023
Amount
Supply & fix wall mounted fan 400 mm sweep, 240 volts osillating type study & heavy duty PVC blades for higher air dilivery nickel chrom plate guard, smooth oscillation complete in exisiting wall etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with and pressed steel terminal box powder coated of suitable size 3 mm thick backlite white/colour sheet top cover ISI marked with brass screws and cup washers for housing switches, socket, fan regulator etc complete all as specified and directed by Engineer-in-Charge for :-
One Fan point/exhaust fan controlled by one, one way switch single pole.
Material and labour for modular switch 1 way 6A 1 module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular socket 6A 5 pin 2 in 1 combined 2 module 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of 3 moduler ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular surface mounting plastic box of 3 moduler ISI marked complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring complete with 2.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 2.5 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed as earth wire continuity with and pressed steel terminal box powder coated of suitable size 3 mm thick backlite white/colour sheet top cover ISI marked with brass screws and cup washers for housing switches, socket, fan regulator etc complete all as specified and directed by Engineer-in-Charge for :-
One 3 pin 5 Amps socket out let on independent board.
Supply & fix double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of isolators, MCBs, etc. In distribution board of the following rating and capacities complete all as specified and directed by Engineer-in-Charge.
MCB SPN of 240 volts 20/32/40 Amps Capacity, 'C' series, 10 KA
MCB SP of 240 volts 5-32 Amps Capacity, 'C' series, 10 KA
Material & labour for sub main wiring with two runs (two runs measured as one run) of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing caping ISI marked with accessories to wall/ceiling with proper saddles and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and one run of conduit will be measured & paid as one unit)
Supply & fix PVC body exhaust fan, AC single phase 230/240V, 50 Hz of size 300 mm sweep with louvers shutter, 1200 RPM copper winding complete all as specified and directed by Engineer-in-Charge. net frame including .( Note: The rate quoted shall be in including making hole of suitable size of the Exhaust fan 300 mm dia in fabric sheet/ CGI sheet making good the side of hole to fit the exhaust fan no extra payment will be allowed to contractor on this regard).
Supply & fix switch piano flush type 230/250 Volt, 5 Amps single pole one way, complete all as specified and as directed by Engineer-in-Charge.
Supply & fix MCB/isolator SP of 240 volts 10 Amps Capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fix MCB/isolator TPN of 415 volts 63 Amps Capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge
Supply & fix switch socket combination 2 in 1, 3 pin 5A flush type univeral complete all as specified and directed by Engineer-in-Charge.
Supply & fix PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engineer-in-Charge.
Supply & fix double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 8 ways with 200 Amp rated bus bar 240 volts powder coated complete all as specified and directed by Engr-in-Charge.
Supply & fix MCB/isolator TPN of 240 volts 40 Amps Capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge
Supply & fix MCB/isolator SPN of 240 volts 40 Amps Capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge
Material & labour for sub main wiring with four runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through and including PVC casing caping ISI marked with accessories to wall/ceiling with proper saddles and 2 runs of 64 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Four runs of conductor with two run of earth wire and one run of conduit will be measured & paid as one unit)
Supply & fix test point terminal block made of gun metal / phosphorus bronze/copper of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw complete all as specified and directed by Engineer-in-Charge.
Supply and fixing GI tubing light grade for mechanical protection of earth strip laid under plinths,floors, roads, paths, culverts etc. or fixed on walls or along poles or emmbeded in PCC for giving support to air termination rod by means of MS clamps with necessary bolts, nuts and washers etc complete all as specified of size 25mm bore complete all as specified and directed by Engineer-in-Charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Fixinf/hanging of existing new geysers of any capacity on wall with 2/4 Nos of stainless steel fastener of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply & fixing CPVC pipes 20mm dia SDR-11 & plain CPVC SDR-11 with all fittings on wall/ceiling or laying in floor/wall complete with proper steel saddling of half meter apart of each complete all as specified and directed by Engineer-in-Charge
Supply & fixing quarter turn bib cock with flange,fancy type,cast brass with chrome finish crutch or butterfly handle ,screwed down ,screwed for iron pipe/CPVC Pipe or for brass ferrule and fixed for size 15mm bore complete all as specified and directed by Engineer-in-Charge
Supply & fixing quarter turn angle cock with flange 15 mm dia cast brass with chrome finish plate screwed down high pressure,fancy type,with long shank and cup(connected type),screwed both ends for iron pipe/CPVC Pipe complete all as specified and directed by Engineer-in-Charge
Supply & fixing Geyser PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and directed by Engineer-in-Charge
Material & labour for point wiring from 4 Way DB to GEYSER socket complete with 4.0 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING&CAPPING INCLUDING accessories etc fixed to wall/ceiling including provision of 4.0 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire connected to common earth dolly for one 15 Amps Independent socket controlled by 15 Amps switch complete all as specified and directed by Engineer-in-Charge. Note:-Switch,socket, etc.shall be measured and paid separately.
Supply & fix switch socket combination 2 in 1, 6 pin 5 and 15 A flush type univeral with PVC box complete all as specified and directed by Engineer-in-Charge.
Supply & fixing including testing of water heater/geyser of vertical type of capacity 35 Ltr, Rated 2000W,230V AC, 50Hz Auto cutoff with a high tech adjustable thermostat,multifuction saftey valve,Magnesium anode coated heating element, rust proof external body with unique polymer protective coated inner tank, red and green indicator lamp, suitable for highrise building suitable for water pressure head upto 8 bars ,high density & thick PUF that ensures energy efficiency and reduced electricity bills ,15 Amps heavy duty plug complete all as specified and directed by Engineer-in-Charge Note:-The rate quoated shall be in including hanging of Geyser in wall with 2/4 nos of stainless steel fastner of suitable size no extra payment will be allowed to contractor in this regard.
Material & labour for plain Cement concrete, type D2, (1:4:8), (using 40mm graded stone aggregate) in foundation and filling mass concrete complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc.incl removing materials to store for kepping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
Taking down old tube light fittings of any description and making good disturbed surface of walls etc complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan/Exhaust fan of any description and making good to disturbed surface of walls etc complete all as specified and directed by Engr-in-Charge (Old ceiling/exhaust fan to be deposited in MES store yard under AGE E/M sub division).
Material & labour for Precast cement concrete block masonry with solid blocks exc 10cm in width Type C1 (1:3:6) (using 20mm graded stone aggregates) and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material & labour for 25 mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub base of floors etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for vitrified ceramic light shade 10 mm thick (sqaure/rectangular) area of each tiles n.exc. 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match existing tiles and including 15 mm thick screed bed or bedding layer of mortar 1:4 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames not exc. 1.5 Sqm each, with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge.
Refixing chowkhat with shutter in order opening complete all as specified and directed by Engineer-in-Charge.
Demolition reinforcement Concrete roofs, floors (other than ground floors) beams, stairscases, landing, chhajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in Soft/ loose soil soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
Material & labour for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Material & labour for 100mm thik PCC 1:2:4, B1 ( 20 mm graded) filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure) complete all as specified and directed by Engineer-in-Charge.
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-in-Charge.
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer-in-Charge.
Material & labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including crancking, bending spiraly for column & hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
Material & labour for mild steel TMT bars 5mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge.
formwork to sides of pillars, posts, struts, piers, columns and stanchions etc complete all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
Material & labour for M-30 reinforment cement concre Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material & labour for M-30 reinforment cement concre for columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.
Material & labour for M-30 reinforment cement concre beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
Material & labour for M-30 reinforment cement concre Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
Material & labour for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces complete all as specified and directed by Engineer-in-Charge.
Material & labour for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 15mm thick in two layers first coat 10mm thick in CM 1:6 and second coat 5mm thick in CM 1:4 with wate proofing compound @3% by wt of cement on fair faces of brick work or concrete surfaces, finished even and fair complete all as specified and directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only water proofing compound complete all as specified and directed by Engineer-in-Charge.
Material & labour for plaster 10 mm thck on concrete surfaces in cement mortar 1:3 finished even and smooth using WPC @ 3% by weight of cement and preparing the surfaces to recive WPT treatment , applying a coat of bitumenm primer confirm to IS - 3384-1986 @ 0.3 Litre per sqm . providing APP modified memrane with non woven polyster reinforcement/mat ( centre core) by tourch application over primed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fixing steel rolling shutters, factory made, without ball bearing, with thickness of laths 1.25mm push and pull or manual type including top cover, anchoring rod, hasp and staple with one shop coat of red oxide or zinc staple with one shop coat of red oxide or zinc chrome primer and fixed in position in existing opening complete all as specified and directed.
Material & labour for preparation of new or previously untreated concrete extrernal surfaces and applying two coats of exterior emulsion paint complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of Acrylic putty by finishing the surfaces even and smooth complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Supply & fix in energy saving ceilling fan 1200mm sweep and connecting up including provision of cable from ceilling rose or connector to fan and complete all as specified and as directed by Engineer-in-Charge . (Note:- Old unserviceable Ceiling fan deposit in AGE E/M store yard)
Supply & fix ceiling rose 3 phase, PVC/ Polycarbonate body complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular fan regulator step type 120 watt 2 module complete all as specified and directed by Engineer-in-Charge
Supply & fix modular socket 6 Amp, 5 pin 2 in 1 combined 2 module 240 Volts complete all as specified and directed by Engr-in-Charge.
Supply & fix modular socket 6/16 Amp, 5 pin 2 in 1 combined 2 module 240 Volts complete all as specified and directed by Engr-in-Charge.
Supply & fix modular switch 1 way 6 Amp 1 combined 2 module complete all as specified and directed by Engr-in-Charge.
Supply & fix modular switch 1 way 16 Amp 1 combined 2 module complete all as specified and directed by Engr-in-Charge.
Supply & fix modular white cover plate with frame of 3 module ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & fix modular white cover plate with frame of 6 module ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & fix modular white cover plate with frame of 8 module ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & fix modular metal flush box 3 module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular metal flush box 6 module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular metal flush box 8 module complete all as specified and directed by Engineer-in-Charge.
Supply & fixbuzzer/ding dong bell AC 230V single pole type complete all as specified and directed by Engr-in-Charge.
Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 10 sqmm, 2.0 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engineer-in-Charge.
Material & labour for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches well ramming and spreading in layers complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x 180 x 40 mm complete all as specified and directed by Engineer-in-Charge.
Supply install testing and commissioning horizontal of openwell submersible pumpsets CI body electric driven single phase 220-240 V AC supply 50 Hz 2880 RPM with a capacity of 1 HP head range 20-35 m and discharge 2.8 LPS of suction and size 25mmx25mm inclusive of submersible cable and starter complete all as specified and directed by Engineer-in-Charge. Note: The rate of brass NRV, football are included in the quoted rate
Supply install testing and commissioning of self priming mini monoblock centrifigal pump with SS trolley mounted wheel & handle electric driven single phase 220-240 V AC supply 50 Hz 2880 RPM with a capacity of 1.5 HP head range 20-35 m and 2.8 LPS of suction and discharge size 25mmx25mm inclusive of copper cable and on/off MCB SPN 20 Amps with enclosure complete all as specified and directed by Engineer-in-Charge. Note: Cost of SS trolley mounted wheel & handle brass NRV football are included in the quoted rate
Supply laying and testing PVC suction hose pipe heavy ridig PVC wire breaded of size 32 mm including fittings complete all as specified and directed by Engineer-in-Charge. Note: Nipple, clamp and fittings i.e. elbow, socket, reducer are included in the quoted rate
Supply laying and testing UPVC pipe with all fittings and fixtures including gate/stop valve laid in trenches/walls/ceiling/floor with all fittings and fixtures of size 25 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply & fix PVC insulated copper cable 3 core 4 sqmm for submersible pump on oiles/walls including conduit of suitable dia with proper size saddles/clamp complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring complete with 1.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated but unsheathed cable 1100 volts grade drawn through and including rigid steel ERW conduit of 25 mm dia (external) heavy duty including necessay flame proof /weather proof conduit accessories and fitting concealed in wall/ceiling etc including sealing threaded jointsin conduit accessories with teflon tape including 1.5 sqmm single core FRLSH PVC insulated but unsheathed multistranded copper conductor cable as in continuous earth.Wiring shall be suitable for flame proof area as per STEC-7 for One flame proof light point controlled by one,single pole flame proof switch complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring complete with 2.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated but unsheathed cable 1100 volts grade drawn through and including rigid steel ERW conduit of 25 mm dia (external) heavy duty including necessay flame proof /weather proof conduit accessories and fitting concealed in wall/ceiling etc including sealing threaded jointsin conduit accessories with teflon tape including 2.5 sqmm single core FRLSH PVC insulated but unsheathed multistranded copper conductor cable as in continuous earth.Wiring shall be suitable for flame proof area as per STEC-7 for One flame proof light point controlled by one,single pole flame proof switch complete all as specified and directed by Engineer-in-Charge.
Supply & fixing flame proof/weather proof 4 feet LED light fitting 2x18 Watt CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix flame proof/weather proof exhaust fan, 12" (300mm), single phase,with and including louvers CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing, complete all as specified and directed by Engineer-in-Charge. Note:-The rate quoated shall be in including making holes of suitable for exhaust fan of size 300 mm dia in PCC block masonry wall, making good the side of hole with CM (1:4) on wall with two coat of paint match with existing wall and distributed surface with 4 nos of stainless steel fastner of suitable size to fit the exhaust fan no extra payment will be allowed to contractor on this regard
Supply & fix flame proof/weather proof rotory on/off switch with termination box in LM6, 16A 2 pole 250 V complete all as specified and directed by Engineer-in-Charge.
Supply & fix flame proof/weather proof switch socket & plug combined in LM6 cable termination box in LM6, 16A 250 V 2P+ earth complete all as specified and directed by Engineer-in-Charge.
Supply & fix flame proof control panel in cast alluminium alloy LM6 construction certified by CMRS dhanbad for group IIA & IIB complete all as specified and directed by Engineer-in-Chargeconsisting of:- Incomong:-MCB SPN 40 Amps-1 No each DB Outcomong:-MCB SP 5-32 Amps-4 Nos each DB
Material & labour for sub main wiring with two runs PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 2.5 Sqmm single core, copper conductor drawn through ERW steel conduit heavy duty ISI mark of size 20 mm external dia and 2.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and one run of conduit will be measured & paid as one unit)
Supply & fix glass door 12 mm thick clear tinted toughned glass incl diamond polish complete with six holes and two patch cut out incl frosting of glass all as per direction of Engr-in-Charge through CNC machine incl ISI marked floor door spring of each shutter incl top patch bottom patch 30 cm long stainless steel handle set and central stainless steel lock complete all as specified and directed by Engr-in-Charge.
Supply & fix anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engr-in-Charge.
Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed by Engr-in-Charge.
Supply & fix collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed by Engr-in-Charge.
Cutting upto a depth of 2.5 cm into concrete walls and trimming surfaces as required girth exc 30 cm complete all as specified and directed by Engr-in-Charge.
Material & labour for point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5mm FRLSH PVC insulated unsheathed copper earth wire including Suitable for switches and sockets complete all as specified and directed by Engineer-in-Charge.
One light point controlled by one, one way switch single pole piano type
One Fan point controlled by one, one way switch single pole.
One 3 pin 5/6 Amps socket out let on same board
One 3 pin 5/6 Amps socket out let on independent board
All as per item No 110 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15/16 Amps socket out let on independent board. complete all as specified and directed by Engineer-in-Charge.
SHREE BHANU ENTERPRISE
Mepani Construction Company
M/s Bombay Novelty Stores
ALBA AC AND REF SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .