Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹32.3 L+₹1.8 L (6.02%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
11 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY
BHUJ
CERTAIN EM WKS TO VARIOUS BLDGS OF POCKET A AND KHAVDA UNDER AGE EM OF GE A BHUJ
2024_MES_653503_1
8214
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹60,000
Yes
13 Jul 2024
11 May 2024
13 Jun 2024
11 May 2024
11 Jun 2024
24 May 2024
Amount
M&L for Disconnecting,taking down and removing of ceiling fan of any description, any sweep and from any position / locations and connecting up from ceiling rose or connector to ceiling fan, necessary oiling and greasing including supplying and replacing of damaged nuts, bolts, rubber seal , clamps and replacement of unserviceable parts if any, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 sqmm 3 core multistanded PVC insulated copperwire FRLS to required length and testing at site complete all as specified and directed. Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Taking out & removing old burnt-out windings of electric celling fans/BLDC fan of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete all as specified and directed.
Supply only bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans complete all as specified and directed.
Supply only bushes gun metal suitable for celling fans 1200/1400mm sweep of any size complete all as specified and directed.
Supply only rubber reel type synthetic rubberwith 14.5 mm hole suitable for hooks of celling fans, complete all as specified and directed.
Supply only nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" lengthcomplete all as specified and directed.
Supply only top/bottom (Set of Two) canopy of required size complete with tightening screws,complete all as specified and directed.
Supply only down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
Supply only condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of suitable for ceiling fan complete all as specified and directed.
M&L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complete all as specified and directed.
Description all as per sil item No 1 here in before but for exhaust of any size/make complete all as specified and directed. Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan 300 to 450mm sweep of different make,complete all as specified and directed.
Supply only exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete all as specified and directed .
M&L for Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complrtr with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust,complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fancomplete all as specified and directed.
Description all as per item No 12 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality complete all as specified and directed.
Description all as per sil item No 1 here in before but for table fan/wall mounted/cabin fan of any size/make complete all as specified and directed. Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Rewinding of table fan/wall mounted/cabin fan of any sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified and directed.
Supply only ball bearing suitable for table fan/wall mounted/cabin fan of different make, complete all as specified and directed.
Supply only frame suitable for table fan/wall mounted/cabin fan frame made out of MS sheet for any make and any size with suitable size of nuts, bolts lugs and washers complete all as specified and directed.
M&L for Painting of table fan/wall mounted/cabin fan frame complete with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust,complete all as specified and directed.
Supply only fan blade suitable for table fan/wall mounted/cabin fan made out of M S sheet/PVC as per existing model suitable for any make , sweep and colour of celling fans complete all as specified and directed.
Labour only for repairing and attending the complaint of geyser by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed.Following items shall be replaced if found defective complete all as specified and directed. Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A"
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size complete all as specified and directed.
(b) Geyser element 1.5 KW, complete all as specified and directed. Make :- Theata/Venus
(b) Geyser element 2.0 KW, complete all as specified and directed. Make :- Theata/Venus
(d) Thermostate switch ISI Marked complete all as specified and directed.
(e) S/S inner tank Capacity 25 Ltrs heavy duty complete all as specified and directed.
(f) S/S Copper inner tank capacity 06 ltr heavy duty complete all as specified and directed.
(g) S/S Copper inner tank capacity 50 Ltr heavy duty complete all as specified and directed.
(h) Indicator lamp of any type/colour complete all as specified and directed.
(i) Top and bottom cover of outer body of any type Geyser suitable for 03/06/25/50 lts capacity including two coats of synthetic enamelled paint and preparation of surfaces complete all as specified and directed.
(j) CP connection 450mm long nylon braided and double flat with nut and washers both side complete all as specified and directed.
(k) -do- but of size 300mm long complete all as specified and directed.
(l) Copper flexible cable PVC insulated 3 core 40/.0076 complete all as specified and directed.
(m) Outer body 50 Ltr capacity Geyser complete all as specified and directed.
(o) Outer body but 25 ltr capacity complete all as specified and directed.
(p) Pressure release valve ISI marked complete all as specified and directed.
(q) Safty plug of geyser for 25/35/50 Ltr capacity complete all as specified and directed.
(r) Plug top 3pin 15 Amps ISI Marked complete all as specified and directed.
(s) Non return valve 15mm dia pipe brass made ISI marked complete all as specified and directed.
Labour only for repairing and attending the complaint of Split/WindowAC by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note 1 :- Replacement of spare part will be measured and paid separately under appropriate items 2 :-Labour charges shall be demmed to be included in quoted rate.
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecnting, dismantling and taking out the non functional Air Conditioner Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 2 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 2 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
Supply only starting relay complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” complete all as specified and directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” complete all as specified and directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 3/8” complete all as specified and directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” complete all as specified and directed.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surfacecomplete all as specified and directed. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR complete all as specified and directed.
Supply only thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only overload protector of followings :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Preparation of old painted surfaces of the following appliacnes, painting with two coats of synthetic enamel paint by spraying complete all as specified and directed for :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only condenser unit of the following appliances including making of all connectiions complete all as specified and directed. following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC of any make and capcity 1.5/2 ton.
Supply only condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Split type AC of any make and capcity 1.5/2 ton.
Supply only bottom tray of window type ACs 1.5/2.0 Ton capacity of any make complete all as specified and directed.
Supply only heavy duty PVC flexible pipe with necessary jubilee clamps for split ACs/Window ACs drains of size :-
(a) 15mm dia bore.
(b) 20 mm dia bore.
Supply only PCB of split type AC Cap 1.5/ 2 TR as per existing make and model complete all as specified and directed.
M&L for providing rubber foam heavy duty insulation tube over the existing copper tubing of any length at any location in replacement of worn out insulation including fixing with cable tie, clamping all as required at site, complete all as specified and directed.
Supply only front grill of window type AC as per sample, complete all as specified and directed.
Supply only air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed.
Supply only new coling fan motor for window type AC1.5TR/2TR, complete all as specified and directed.
Supply only new cooling fan motor for split type AC of 1.5/2.0 TR capacity, complete all as specified and directed.
Supply & Fix in replacement MS stand factory made suitable for condensing unit of split type AC duly powder coated all as specified and as directed.
supply and fix swing motor suitable capacity for window/split AC complete all as specified and as directed.
M&L for servicing Water coolers 40 to 150 ltrs cooling of comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :- Note 1 :- Replacement of spare part will be measured and paid separately under appropriate items 2 :-Labour charges shall be demmed to be included in quoted rate.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure for Water coolers 40 to 150 ltrs capacity.complete all as specified and directed by Engr-in-Charge for the following appliances:-
Supply only starting relay of Water coolers 40 to 150 ltrs capacity.complete all as specified and directed. for the following appliances:-Make- Hitech
Supply only thermostats for water coolers 40 to 150 ltrs capacity complete all as specified and directed.
Supply only overload protector Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
Preparation of old painted surfaces of the for Water coolers 40 to 150 ltrs capacity., painting with two coats of synthetic enamel paint by spraying complete all as specified and directed.
Supply only condenser unit for water coolers 40 to 150 ltrs capacity. including making of all connectiions as specified and directed complete all as specified and directed.
Supply only cooling coil for water coolers 40 to 150 ltrs capacity complete all as specified and directed.
Supply only top cover gasket of water cooler 40 to 150 ltrs capacity complete all as specified and directed.
Supply only internal wiring kit complete for water coolers 40 to 150 ltrs capacity complete all as specified and directed.
Supply only condenser fan motor complete for Water coolers of any make and cap 40 to 150 ltrs capacity. with necessary mounting bracke to and base frames complete all as specified and directed.
S&F in replacement of water tap for water cooler of capacity 40 Ltrs / 150 Ltrs, complete all as specified and directed.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
S & F in replacement of float valve assembly Complete suitable for water cooler of any size/cap Non metallic body complete all as specified and directed.
M&L for servicing of refrigerator of capacity 165 to 310 ltr comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :- Note 1 :- Replacement of spare part will be measured and paid separately under appropriate items 2 :-Labour charges shall be demmed to be included in quoted rate.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply only starting relay Refrigerator of 165 to 310 ltrs capacity. complete all as specified and directed. Make- Hitech
Supply only thermostats for Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply only overload protector Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Preparation of old painted surfaces of the following appliacnes, painting with two coats of synthetic enamel paint by spraying for refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply only condenser unitRefrigerator of 165 to 310 ltrs capacity. including making of all connectiions complete all as specified and directed.
Supply only cooling coil Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply only internal wiring kit complete sutaible for Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
Supply only magnetic door gasket of refrigerant 165 to 310 Ltrs cpacity complete all as specified and directed.
Supply only ice tray with PVC cubicle separater complete all as specified and directed.
Supply only cabinet bulb of refrigerators of suitable size and capacity complete all as specified and directed.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
M&L for servicing of Deep freezers of Upto 425 ltrs capacity. comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :- Note 1 :- Replacement of spare part will be measured and paid separately under appropriate items 2 :-Labour charges shall be demmed to be included in quoted rate.
M&L for checking for leakages of Deep freezers of Upto 425 ltrs capacity., creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed.
Supply only starting relay for Deep freezers of Upto 425 ltrs capacity. complete all as specified and directed. Make- Hitech
Supply only capacitors of the following capactities for ACs, water coolers, Refrigerators, Deep freezers etc as per site requirement complete all as specified and directed.
Supply only overload protector for Deep freezers of Upto 425 ltrs capacity complete all as specified and directed.
Preparation of old painted surfaces Deep freezers of Upto 425 ltrs capacity, painting with two coats of synthetic enamel paint by spraying complete all as specified and directed.
Supply only condenser unit for Deep freezers of Upto 425 ltrs capacity. including making of all connectiions as specified and directed complete all as specified and directed.
Supply only cooling coil for Deep freezers of Upto 425 ltrs capacity complete all as specified and directed.
Supply only internal wiring kit complete sutaible forDeep freezers of any make & cap 200 to 425 ltrs capacity complete all as specified and directed.
Supply only condenser fan motor suitable for Deep freezers of any make & cap 200 to 425 ltrs capacity. complete with necessary mounting bracke to and base frames complete all as specified and directed.
Taking down defective /unserviceable Deep freezers (capacity upto 425 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank etc, complete all as specified and directed.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed.
M&L for rewinding of desert cooler fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed.
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as specified and directed.
Supply & fixing in replacement of Capacitor 4 MFD complete all as specified and directed. MAKE:- Usha/Universal/Epcos
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness complete all as specified and directed.
Supply & fixing in replacement of old rusted front panel with show grill of desert cooler with new grill made out of GI sheet 22 SWG complete with front show plate with ON/OFF switch for pump & four speed regulator for fan of approved make complete all as specified and directed.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed.
Supply and fixing indoor unit of split type AC 2 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor,swing blade filter, PCB, Thermostate etc complete all as specified and as directed. Make- Voltas/ LG
Supply and fixing in replacement to worn out door unit of split type AC of cap 2 TR. comprises of condensor, condenser motor, condensor fan and blade , capacitor, suction, discharge valve, outer cover duly powder coated etc complete all as specified and as directed.Make-Voltas/ LG.
Supply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete all as specified and directed.
Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete all as specified and directed.
Supply& Install Desert cooler steel body , electric driven (single phase), having nominal air flow capacity of 4000 CFM , Honeycomb cooling pads design, ice chamber,water level indicator,Four way air deflection,Easy Mobility complete all as specified and directed.
Supply and install hi wall inverter type split units indoor and outdoor complete with cordless remote control unit and with in built air filter for better indoor air quality with minimum 5 star rating single phase 240 Volts 50 HZs of 1.5 Ton complete with all fixing acessories. (a) Room evaporator indoor unit with speed blower fan of approipriate capacity including PCB , thremostatic control , air filter and drain for condensing water. (b) Outdoor condensing unit of capacity 5175 Kacl/Hr capacity with condensor fan motor of appropriate capacity - 01 No. Air cooled condensor of capacity 1.5 TR - 01 No.Shall be installed outside the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installing of ACs. (c ) Refrigerant cooper pipe of suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit withy control valves & safety acessories invcluding complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable. (d) Making good the disturbed surface to match with the existing surface complete all as specified and directed.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rate complete with all fixing acessories, temperature display complete all as specfied and directed.
Supply and fix in replacement of BLDC fan PCB(Control board ) complete all as specfied and directed.
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works of appliances.
(2) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(3) All tools &tackles, plants, machineries, equipment and material to carry out the work at site to be provided by the contractor at his/ her own cost. Workshop shall be setup for rewinding/ repair of ceiling fan, exhaust fan, wall mounted fan, refrigerator, deep freezer & desert cooler etc. Rewinding machine should be installed in workshop with the latest configuration.
(4) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(5) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(6) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(7) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(8) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(9) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(10) To carryout the serving of AC, refrigerator, deep freezer & water cooler, following T&P should be brought at site (service centre):-
(i) Drilling machine for making hole in wall.
(ii) Jet spray for cleaning of indoor and outdoor units.
(iii) Vacuum cleaner and blower
(iv) Ref mechanic tools kit
(11) It is responsibility of contractor to clean the area after repairwork of appliances. Rates are deemed to be include in his quoted rates of respective items.
(12) The same nature of complaints in same location shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(13) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(14) Contractor shall identify the real cause of burned winding of fan motor. Winding problems that are identified should be documented. Then, winding of fan motors shall be cut/ removed completely in presence of officials. Rewinding of same shall be carried out with proper copper gauge wire.
(15) Job card /Docket shall be maintaned properly mentioning as below: a) service Number b) Name c) Rank d) unit e) Date Format of docket/job card shall be provided to contractor. Date of receiving & Date of resolving with time shall be endosrsed on job card.
(16) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge.
(17) Stationery such as complaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
sudarshan builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .