Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹9.8 L+₹3,169.35 (0.32%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.0 L+₹19,183.80 (1.96%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹10.1 L+₹26,362.80 (2.69%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹10.3 L+₹47,894.80 (4.88%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹9.7 L
EMD Value
₹19,300
Closing Date
16 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
2024_MES_669531_1
8623
Open Tender
Civil Works
Item Rate
60 days
AGE (I) SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
Yes
₹19,300
Yes
26 Sept 2024
2 Sept 2024
18 Sept 2024
2 Sept 2024
16 Sept 2024
10 Sept 2024
2 Sept 2024 - 3 Sept 2024
Amount
Taking down cement or cement lime plaster, any description, on brick walls including racking out joints hacking for key scrubbing down with water etc. all as specified and directed.
Demolition of Brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as directed.
M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 finishing even and smooth with out using extra cement all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in two layers, first layer 10 mm thick in CM 1:6 and second layer 5 mm thick in CM 1:4 finishing fair and even mixed with WPC as per manufacturer's instructions all as specified and directed. (Note : Supply of water proofing compound shall be measured and paid seperately).
M&L for Brickwork with sub-class `B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 all as specified and directed.
M&L for dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc.laid complete all as specified and directed by Engr-in-Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level )including removal of demolished material out side MD land complete all as specified and directed by Engr-in-Charge.
Cement concrete 25mm tk type B- 0, 1:2:4 (12.5 mm graded stone aggregate) as in sub base all as specified and directed.
M&L for joint free Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15 mm thick screed in cement mortar mortar 1:6 all as specified and directed.
M&L for 100 mm high skirting with joint free non Skid ceramic coloured tiles (matt finish) 7 to 8 mm thick high area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 10 mm thick backing coat in cement mortar mortar 1:4 all as specified and directed.
Taking down chowkats or frames (without taking off shutters from frame) not exceeding 1.5 sqm each all as specified and directed.
Taking down chowkats or frames (without taking off shutters from frame) exceeding 1.5 sqm but not exceeding 4 Sqm each all as specified and directed.
S&F of Pressed steel frames 125 x 60mm size for doors with double rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed all as specified and directed.
S&F of Pressed steel frames 105 x 60mm size for doors with double rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-0 using 12.5 mm graded stone aggregate for filling of hollow portions of door frames etc., all as specified and directed.
S&F of 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F for 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze etc. divided in to squares, with plain chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamferred or rounded, fitted with cut and mitred beads for securing glass, wire gauge etc. ; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats all as specified and directed.
S&F of powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc., complete all as specified and directed by Engineer-in-charge.
S&F of powder coated aluminium window and ventilator glazed shutters, side hung type without sash bars aluminium sections weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21, 100mm long (2Nos), suitable handle (1Nos) for each shutter complete all as specified and directed by Engr-in-charge.
S & F of Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden/aluminium beeds all as specified and directed.
S&F of 4 mm thick Sheet Glass, ordinary quality and glazing with aluminium beads all as specified and directed.
S&F of 4 mm thick Figured glass, pin hea type and glazing with aluminium beads all as specified and directed.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded section all as specified and directed.
S&F of 150 mm long Aluminium handles cast type anodised all as specified and directed.
S&F of 300 mm long aluminium alloy anodised sliding door bolts with hasp and staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified and directed.
S&F in repairs of mild steel 300 mm ,ordinary rat & tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for Preparing new or previously un treated surfases of wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L for preparing new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior weather coat paint over a coat of primer all as specified and directed.
M&L for complete removal of existing treatment on old surfaces of walls and applying two coats of exterior weather coat paint over a coat of primer all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer all as specified and directed.
M&L for complete removal of old painted surfaces of walls and applying and two coat of oil bound distemper over a coat of primer all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof covering etc complete all as specified and as directed
Supplied and fixed pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws etc complete all as specified, directed and as per manufacturer's instructions.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of Fe 550 Mpa as in roof ridge fixed with self tapping screws as specified.
Dismantling of framed roof truss not exceeding 10m span complete all as spd and as directed.
Dismantling of timber scantlings udner 40 Sqcm in fillets, rails, runners, purlins framed work (Runners/battons) complete all as spd and as directed.
S&F rolled mild steel in roof trusses (framed) Fe-290 (Gde-E-165), trussed, purlins, crane gantries, rails and fastenings and heay bracket framing (beam, tee, angle, channel of flat sections) including distance pieces, cleats etc complete all as spd and as directed.
Rolled mild steel sections conforming to Fe-290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as spd and as directed.
M&L for Cement concrete type B-1 1:2:4 ( using 20mm graded stone aggregates) as in bed plates, apex stones, coping etc complete all as specified by Engineer-in-charge.
S&F for mild steel machine made screw bolts of 5 to 10mm dia (diameter of neck in mm) hexagonal or square heads at one end and screwed the othe, screwed end fitted with washers and one hexagonal or square nut exc 5cm but n.exc 10cm long all as specified and directed by Engineer-in-Charge
S&F for mild steel machine made screw bolts of 5 to 10mm dia (diameter of neck in mm) hexagonal or square heads at one end and screwed the othe, screwed end fitted with washers and one hexagonal or square nut exc 15cm but n.exc 22.50cm long all as specified and directed by Engineer-in-Charge
M&L for form work to sides of pillars, columns, bed plates etc with rough finished surface of concrete complete all as specified
M&L 75mm thick cement concrete type C-2 1:3:6 (40mm graded aggregate) as in plinth protection complete all as specified and as directed.
M&L for 20-25 mm thick Kota stone slabs in floorings laid and jointed with grey cement slurry mixed with pigment to match the shade of the salb including rubbing and polishing and laid over and including 20 mm thick cement screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for 20-25 mm thick Kota stone slab as in risers of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4, and jointed grey cement slurry mixed with pigment to match the shade of the salb including rubbing and polishing complete all as specified and directed.
M&L for rounding to the edges of stone slabs one edge as in steps, cooking platform, and other similar situations all as specified and directed.
Supply only liquid water proofing compound
BEEGEE DESIGN SYSTEMS (BID ID -3094710)
M/S SIRI BUILDERS (BID ID -3093206)
K VENUGOPALA SWAMY (BID ID -3092650)
DHANA CONSTRUCTIONS (BID ID -3093416)
SHIKHARA PROJECTS (BID ID -3095098)
HARSHA CONSTRUCTIONS AND ENGINEERING WORKS (BID ID -3092906)
KSN PROJECTS (BID ID -3096734)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .