Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 CrAccepted-AOC | ₹23.8 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹25.4 CrRejected-Finance | ₹25.4 Cr | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | L3₹27.0 CrRejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹27.0 Cr | L3 | Rejected-Finance Being other than lowest tenderer |
| 4 | L4₹27.7 CrRejected-Finance | ₹27.7 Cr | L4 | Rejected-Finance Being other than lowest tenderer |
| 5 | L5₹28.9 CrRejected-Finance FIRST FLOOR PLOT NO 440 SECTOR NO 1 GAYATRI MANDIR ROAD GANDHIDHAM KACHCH GUJARAT 370201 | KACHCHH | GUJARAT | 370201 | ₹28.9 Cr | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹25.5 Cr
EMD Value
₹15 L
Closing Date
28 Jan 2025, 6:00 pmClosed
Chief Engineer
Chief Engineer Jodhpur Zone pin 900066 c/o 56 APO
PROVN OF DEFI MD ACCN FOR ORs AT GANDHIDHAM MIL STATION.
2024_MES_684337_1
800604/Bhuj/E8
Open Tender
Civil Works - Canal
900 days
Gandhidham
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (A) Bhuj
₹15 L
Yes
HQ CE Jodhpur Zone
11 Apr 2025
18 Nov 2024
4 Feb 2025
18 Nov 2024
28 Jan 2025
14 Jan 2025
5 Dec 2024
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 28
Lump sum price worked out by the contractor for "SITE CLEARANCE EXCAVATION & EARTH WORK " as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 29 (R)
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY WORK " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 30(R)
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 35(R)
Lump sum price worked out by the contractor for "ROAD , PATH, CULVERT AND CATTLE TRAP WORK" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 42(R)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 44
Lump sum price worked out by the contractor for "AREA DRAINAGE WORK" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 46
Lump sum price worked out by the contractor for " SECURITY FENCING & GATE WORK" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 49(R)
Lump sum price worked out by the contractor for " STAND BY ELECTRIC SUPPLY WORK" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 50(R)
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY WORK" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 51
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION WORK" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 55(R)
Sch 'A' PART-XII (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
INTERNAL WATER SUPPLY Supply and fixing of 15 mm bore fancy type chromium plated bib tap with wall flange, screwed for iron pipe or CPVC pipes or for ferrule and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of 15 mm bore fancy type chromium plated pillar taps swan Neck tap with right hand operating Knob and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of 15 mm bore fancy type chromium plated concealed stop cock, reduced body with adjustable wall flange, and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of 15 mm bore fancy type chromium plated sink cock with swinging spout (wall mounted model) with wall flange and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of 15 mm bore fancy type chromium plated angular cock, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of central Hole Basin Mixer with regular spout with popup waste system with 450 mm long braided hoses and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of CP wall mixer 2 in 1 system with provision with central spout and connection for over head shower with divertor liver ISI marked complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of overhead shower 114x114 mm of square shape single flow with rubit cleaning system ABS body crome plated with gray face plate with arm having swivel joint chromium plated complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
Supply and fixing of health faucit (ABS Body) with 1000 mm long flexible mild steel tube 15 mm dia with wall hook complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx 'C'.
INTERNAL ELECTRIFICATION Supply and fixing load line distribution board TPN vertical, 4 way gouble door type, fixed on wall semi flush with incoming MCCB 4 Poles 125 Amps, 16 KA, busbars, neutrakl link blanking plates complete all as specified and as directed.
Supply and fixing TV sockets complete with all accessories complete all as specified and as directed.
Supply and fixing PVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450 mm long complete all as specified and as directed.
Supply and fixing LED lamp B22 base 10 w Minimum lumen out put 950 lumens at 6500 K CCt for batten holders complete all as specified and as directed.
M & L for inverter point wiring for one light, ceiling fan and 5 Amp socket for each room with 2.5 sqmm,PVC insulated, unsheathed, single core multistandard copper conductor cable ( FRLS), 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with its acessories upto the main DB and 15 A switch socket combination with gang box flushed in wall for inverter power supply complete all as specified and as directed.
S & F LED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30W output operating voltage 140-280V with connection by three core PVC insulated multistranded copper conductor sheathed cable of size 1.0 sq mm fixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed.
SEWAGE DISPOSAL WORK M & L for construction of RCC septic tank 150 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls,base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter conventional type as per TD drg no CEJZ/STR/25-G/2021dt 20.01.2022 complete all as specified and directed.
M & L for Soakage wells having size 3.6m dia X 6.0m effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats as per TD drg No CEJZ/STR/STD/14/2016 dt 31.03.2016 complete all as directed and specified
M & L for On site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 User complete all as specified and directed.
M & L for Soakage wells having size 2.4m dia X 3.0m effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats TD drg No CEJZ/STR/STD/14/2016 dt 31.03.2016 complete all as directed and specified.
SECURITY FENCING & GATE Supply and fixing of CI wheel as rollers of 75 mm dia for gates complete all as specified and directed.
STAND BY ELECTRIC SUPPLY WORK Supplying, installing, testing and commissioning Disesel Engine driven generating set 415 volts, 3 phase, 4 wire, engine as per IS : 10001/10002 and alternator as per IS 13364 with inbuilt AMF panel complete with foundation as per design, control panel withnecessary meter and sound proof canopy as per CPCB norms of capacity 25 KVA with all tools & spares complete all as specified & directed and comprising of the following :-
EXTERNAL WATER SUPPLY Supply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 100 mm dia bore with spigot and socket ends, centrifugally cast, class K-9,with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and matallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed.
Supply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 150 mm dia bore with spigot and socket ends, centrifugally cast, class K-9,with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and matallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed.
Supply, laying, jointing and testing of MS ERW pipes of size 200 mm dia bore heavy grade with all fittings, as per IS: 1239 (latest revision) and other relevant standards and matallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length laid in trenches including testing on completion complete all as specified and directed.
Supply and fixing of cast iron air valves with two air outlets 50 mm dia bore and fixing up in cast iron water supply mains including testing on completion complete all as specified and directed.
Supply, install, test and commissioning self priming centrifugal pumpset 10 HP foot mounted, fan cooled motor suitable for 415V, 3 phase, 50Hz, insulation class F, ambient of 50 C conforming to IS 12615 : 2011, IEC 60034-30-2008 and IP 65 protection, base plate, platform as per manufacturer drg, flexible joint, suction & delivery side complete all as specified and directed
Supply, install, test and commissioning self priming centrifugal pumpset 5 HP foot mounted, fan cooled motor suitable for 415V, 3 phase, 50Hz, insulation class F, ambient of 50 C conforming to IS 12615 : 2011, IEC 60034-30-2008 and IP 65 protection, base plate, platform as per manufacturer drg, flexible joint, suction & delivery side complete all as specified and directed
Material and labour for installing, testing and commissioning fully automatic self starter panel for 10 HP centrifugal pump set , outdoor type , double door , KIOSK type , IP - 55 ,locking arrangement, three phase, 430 V, 50 Hz, suiatble rating semiconductoer fuse, CRCA sheet 3 mm thick metal enclosure, duly powder coated and angle iron frame which is made out of 50x50x6 mm angle iron, factory fabricated cubical type weather proof, copper bus bar with sleeves as per colour coding ,Digital Volt meter and Amp meter , Multifunction meter , Indicator for RYB and ON & OFF , including all electric connection , mounting on floor, civil work, including following protection:- (i) Under voltage & Over Voltage (ii) Under load & Over load (iii) Single phase preventor (iv) phase reversal (v) Earth fault (vi) Short circuit (vii) Unbalanced voltage (Negative phase sequence relay) (viii) Switching surge
Material and labour for installing, testing and commissioning fully automatic self starter panel for 5 HP centrifugal pump set , outdoor type , double door , KIOSK type , IP - 55 ,locking arrangement, three phase, 430 V, 50 Hz, suiatble rating semiconductoer fuse, CRCA sheet 3 mm thick metal enclosure, duly powder coated and angle iron frame which is made out of 50x50x6 mm angle iron, factory fabricated cubical type weather proof, copper bus bar with sleeves as per colour coding ,Digital Volt meter and Amp meter , Multifunction meter , Indicator for RYB and ON & OFF , including all electric connection , mounting on floor, civil work, including following protection:- (i) Under voltage & Over Voltage (ii) Under load & Over load (iii) Single phase preventor (iv) phase reversal (v) Earth fault (vi) Short circuit (vii) Unbalanced voltage (Negative phase sequence relay) (viii) Switching surge
Supply and fixing of cable PVC insulated copper conductor flat 3 core 16 sqmm 1100 volt complete all as specified and directed
Supply and fixing of cable PVC insulated copper conductor flat 3 core 10 sqmm 1100 volt complete all as specified and directed
Supply and fixing of foot valve conforning to IS 4038 100 mm diameter including strainer complete all as specified and directed
M & L for Construction of new PCC solid Masonary valve chamber of size 450 x 450 x 650 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 50 mm X 50 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M & L for Construction of new PCC solid Masonary valve chamber of size 1000 X1000 X 900 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Supply and fixing Water level Sensor suitable for 50000 Gln water Capacity Over head Tank Type-Hydrostatic, Range-0-4 Meter Output-4 to 20 Mili Amp complete all as specified by Engineer in Charge.
Supply and fixing Water level indicator 7 segment 4 digit LED dis play.Input-4 to 20 Mili Amp.Power Supply-230 Volt AC complete all as specified by Engineer in Charge.
EXTERNAL ELECTRIFICATIONS Supply, install, test and commisioning copper wound step down transformer, Level 2 ,outdoor type, including plinth PCC platform complete with stranded fittings, ONAN, Vector group DYN11, HT 11 KV, 3 phase, LT, 433 Volts 3 Phase, 4 wire all as per IS 1180 ( Part- I ) : 2014 and designed on minimum 5 star rating with EEL 03, consideration with off load tapings on primary side to vary secondary voltage +/- 5% with taping at every +/- 2.5% of capacity 315 KVA complete all as specified and including the following:-
(a) Three Nos porcelain bushings HT 11 KV with bushing rods, nuts and washers inside cable end box . (b) One cable box LV side consisting of 4 Nos porcelain with brass bushing rods, complete with nuts and washers with two nos cable gland of suitable size. (c) Oil conservator with filler type drain valve and oil level gauge. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) Rating plate and terminal marking plate. (h) The earthing terminal two Nos to tank to faciliate fixing of earth strip.
(j) Oil filling hole with cap/plug with connection plate complete. (k) Lifting hook. (l) Oil level gauge and oil drain filter valve. (m) air relief valve plug. (n) Detachable rollers(4 Nos). (o) Initial filling to transformer oil. NOTES:- (i) Contractor shall submit the technical drawing, constructional drawings, safety features drawing etc. for approval of accepting officer. (ii) The contractor shall intimate for factory inspection for routine tests as per IS & ANSIC?57.12.90 (latest revision) in the OEM factory in presence of representative nominated by the accepting officer before dispatch from factory, tests after installation shall also be carried by SEI for which GE will intimate through proper channel. (iii) Foundation as per manufacturer design shall deemed to be included in the quated rate.
Supply and lay PVC insulated PVC sheather cable , electric control cable with stranded copper conductor of size 2.5 sqmm 2 core 1100 volts grade complete all as specified and directed.
M & L for cable route indicator shown "HT UG cables" painted in brown colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specified and directed.
Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK type totally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (Main panel). Note:- Rate of earthwork and PCC work are deemed to be inclusive in this item.
Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK type totally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (LT panel No - 1) (a) Aluminium Bus Bar suitable for 200 Amp, TPN - 01 set Note: Rate of earthwork and PCC work etc are deemed to be inclusive in this item.
Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK type totally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (LT panel No - 2) Note: Rate of earthwork and PCC work etc are deemed to be inclusive in this item.
Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK type totally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (LT panel No - 3) (a) Aluminium bus bar suitable for 400 Amps, TPN - 01 set Note: Rate of earthwork and PCC work etc are deemed to be inclusive in this item.
Supply, installation, commissioning and testing of company make Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 150 KVAR in 6 steps (50 KVAR fix compensation + 25 KVAR x 2 Nos + 20 KVAR x 2 Nos + 10 KVAR x 1 No ) complete with relays, capacitor banks for automatic operation to power factor above 0.95. The panel should be complete with TP air break contacts of capacitor contacts of duty with suitable swicthgear, MPP heavy duty shunt capacitor impregnatd, having rated voltage of 440 V type with internal electrical swicth gear each element as per IS 13340-1993/IS 13341-1992, IEC 60831 Part I & 2 of outdoor type double door (KIOSK type) complete with interconnections with suitable size of copper wiring, PVC insulated unarmoured cable and PVC sheath etc as required. The panel shall be made out of 3 mm thick CRCA shett powder coated with angle frame of size 50X50X6 mm cubical type including interconnetion wiring, indicating lamps etc confirimng to IP 42 specifications including grounding of panel as per electrical standards, electrical connections shall be made by using proper thimbles/lugs, cable gland complete all as specified and directed as follows: Note: Rate of earthwork and PCC work etc are deemed to be inclusive in this item.
Supply and fixing pole mounted thermoplastic cable junction box for street light with IP-66 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of size 200mm x 160mm x 98mm with front door opening system including terminals for one incoming and two outgoing cables of size 16 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed
M/s Matadeen Ramchandra Agarwal (BID ID -3220734)
M/s godara infratech and power industries (BID ID -3221747)
SHREE GURUKRUPA CONSTRUCTION CO. (BID ID -3217958)
M/s. Mohandas V Rajani (BID ID -3219157)
Hariom Projects Pvt Ltd (BID ID -3220162)
DHARIWAL TRADERS PRIVATE LIMITED (BID ID -3226038)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid