Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.3 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 1 | Accepted-AOC AOC | |
| 2 | 2₹47.3 L+₹2.0 L (4.34%)Rejected-AOC | 2 | Rejected-AOC NOT ACCEPTED | |
| 3 | 3₹47.7 L+₹2.4 L (5.20%)Rejected-AOC BLOCK NO 11 VIMLNATH APARTMENT PRATAP VILAS ROAD NEAR SATYA SAI SCHOOL JAMNAGAR GUJARAT 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | 3 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
5 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
GE ARMY BHUJ
COMPREHENSIVE MAINTAINENCE OF CERTAIN MISC B/R WORKS AT KS LINE - II UNDER AOR OF AGE BR II OF GE(A) BHUJ AT MIL STN BHUJ.
2023_MES_617798_1
8141
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE A BHUJ
₹54,000
Yes
12 Oct 2023
8 Sept 2023
7 Oct 2023
8 Sept 2023
5 Oct 2023
23 Sept 2023
Amount
M&L for aggregate for loose filling, of gauge 20 mm to 63 mm graded Spreading and levelling in layers n exc. 10cm thick.
M&L for Providing prrecast cement concrete Type B1 1:2:4 (20 mm graded aggregate) in appex stone/kerb stone with plain fair faces including chamfers, weathering throting etc and set in cement mortar 1:4 complete with joints to math size and shape as approved by Engr-in-Charge
M&L for 75 mm thick plain cement concrete type D-2 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for Sand filling under floors or in foundation icl watering and consolidation for laying interlocking tiles.
M&L providing precast cement concrete rubber moulded coloured interlocking tiles 80 mm thick (M-40 grade) with grey cement and pigment of approved design and pattern complete all as specified and directed by Engr-in-Charge
M&L for preparation of new concrete surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer all as specified and directed.
M&L for preparation of old painted concrete surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint all as specified and directed.
Demolition of concrete block masonry built in cement mortar or cement lime mortar
M&L for Pre-cast cement concrete block masonry (Type C1, 1:3:6, 20mm aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed.
M&L for exterior grade, coloured, cement concrete designer chequered tiles of size 20cm x 20cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc
Excavating all filled and accumulated earth, rubbish, foreign material from the drain including removing excavated material n.exc 100m and depositing where directed at a level n.exc 1.5 above the starting point all as specified and as directed
Taking down cement plaster on brick or stone wall including racking out joints, hacking for key scrubbing down with water etc complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound (Note :- WPC shall be measured & paid separately)
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enameled paint complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls & applying three coat of white wash wall complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
M&L for manufacturing of ornamental and decorative type steel gate with structural steel conforming to Fe 410-o or 310-O all as specified, revolving on bearing plate including pintal hinges fixed on pillar in PCC blocks of size as required as site , including all locking arrangement, all as per sample approved by the Engr-in-Charge and directed and fixed in position. Note :- 1. Necessary arrangement for weighting the steel gate shall be made by the contractor at his own expense . The contractor shall quote the unit rate accordingly. 2. Steel gate shall be manufactured as per sample approved by the Engr-in-Charge . Photographs for the samples shall have to be collected by the contractor from the manufacturer of the gates in the area for approval of the Engr-in-charge. The cost of the same shall be deemed to be inclusive in unit rate accordingly.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10sqm on plan and n 'exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed
Excavation in trenches n.exc. 1.5m wide and exc 1.5 m & n exc 3m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm dia pipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),200 mm dia pipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge
M&L for concrete bed to drain pipes in cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under, and haunching against the side of the pipes after they are laid tested for pipes of 150mm dia complete all as specified and directed
M&L for concrete bed to drain pipes in cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under, and haunching against the side of the pipes after they are laid tested for pipes of 200mm dia complete all as specified and directed
S&F jointing and testing for reinforced concrete drain pipes, 150mm bore, class NP-2, laid and jointed with collar in CM (1:1) complete all as directed by Engr-in-Charge
S&F jointing and testing for reinforced concrete drain pipes, 200mm bore, class NP-2, laid and jointed with collar in CM (1:1) complete all as directed by Engr-in-Charge
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping exposed surfaces finished even and smooth using extra cement including necessary form work complete all as specified and directed by Engr-in-Charge.
Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed by Engr-in-Charge
Removing excavated soil/ materials to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as directed by Engr-in-Charge
Demolition of concrete (unreinforced) of any description and in any position not specifically provided for complete all as directed by Engr-in-Charge
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation of manholes, mass concrete etc. complete all as directed by Engr-in-Charge
M & L Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1) smooth finished, and reforming benching as required for 150 mm dia of pipe
M & L Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1) smooth finished, and reforming benching as required for 225 mm dia of pipe
Taking down carefully ceilling fans of any size, type by disconnecting the wires and dismanting blades and removing fan and blades to contractor,s workshop or site for repair/ overhauling/re winding/painting etc including re fixing after neccesary repair complete all as specified and directed by Engineer-in-charge.
Description all as per sil item No 1 here in before but for exhaust/cabin fans of any size/make
M&L for servicing/oiling and greasing of fan of any size/type by using appropriate grade of oil/grease and replacing defective parts such as bush, bearing split pin rubber bush hanging clamp capacitor including cleaning for fixing the same as directed by Engineer- in -Charge (Note|-Parts/components will be measured and paid seperately under their respective items)
M&L for rewinding of celling fan 1200mm /1400mm sweep, AC, 230 volts single phase with super enamelled copper winding wire of appropriate size including packing, insulating material soldering varnishing assembling and testing as required complete all as specified and directed
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified
S&F bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans.
S&F bushes gun metal suitable for celling fans 1200/1400mm sweep/exhaust fan 300 to 450mm sweep/cabin fan of any size complete all as directed by Engr-in-Charge
S&F ball bearing suitable for exhaust fan 300 to 450mm sweep of different make, all as directed.
S&F rubber reel type synthetic rubberwith 14.5mm hole suitable for hooks of celling fans, all as specified and directed by Engr-in-Charge.
S&F condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD all as directed
Description all as per item No 10 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality
Dismantling of geyser from its location 03/06/25/50Ltrs cap and making leak proof by means of welding of tanks replacement of parts, under item No 2 and one coat of primer for inner tank re-assembling, including packing of glass wool properly replacement of worn out nut bolts washers screws as reqd and re fixing after neccesary repair of complete set to work after one coat of synthetic enamelled paint as directed by Engr-in-Charge.
Supply and fixing of following items for geyser complete.
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size and directed by Engr-in-Charge.
(b) Geyser element 1.5 KW, all as specified. Make :- Theata/Venus
(c) Geyser element 2.0 KW, all as specified. Make :- Theata/Venus
(d) Thermostate switch ISI Marked.
(e) Plug top 3pin 15 Amps ISI Marked .
Dismounting, window AC 1.5/2.0 TR to the ground level, transporting to near water point in the complex, taking out the AC from outer cover, washing the unit with soap solution jet followed by clean water jet, drying, wiping, transporting back & re-fixing at original position complete all as specified and directed by Engr-in-Charge.
Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth complete all as specified and directed by Engg-in charge. Note:- Cost of hiring T&P i.e. blower, pressure pump bucket hose pipe deemed to be included.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-
(a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 1.5 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC rotary compressor of any make of capacity 2.0 TR and replacing with new rotary compressor of make Tecumseh, Toshiba, Mitsubishi, Hagelin refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 1.5 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable AC reciprocating compressor of make Tecumseh /kirloskar /emerson of capacity 2.0 TR , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
Supply and replace capacitors of the following capactities for ACs water coolers, refrigerators, etc as per site requirement.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed by engineer-in-Charge. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of wire remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR.
Supply and replace thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c ) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
Supply and replace condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
Supply and replace cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
Supply and replace condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Water coolers of any make and cap 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Deep freezers of any make & cap 200 to 425 ltrs capacity.
S&F in replacement of PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed by Engrs - in- charge.
S&F, replacement to air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed by Engineer-in-Charge. Make : Khaitan/Universal or equivalent.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engineer-in-Charge. Make:- Khaitan/ Victor/ Americal/ Universal
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed by Engr-in-charge.
Supply & fixing in replacement of capacitor 4 mfd make Usha/Universal/Epcos
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness as directed.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank, etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) reciprocating compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Dismantling of defective centrifugal pump set/open well pump set, of any make/Model for repairing and reassembling including replacement of defective spare parts by new one of capacity of 5 HP pump set including required MS stud with nuts and bolts etc all as required. Note: (i) Spare parts of the centrifugal pump sets shall be measured and paid separately under relavent item of schedule. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop.
M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 5 HP Motor.
Supply only suitable size bearing for induction motor of 5 HP , after taking out old unservicable complete all as specified and directed at site etc.
Supply and fix in repairs RO Membranes Brakish Water Spiral (CPA3) type, capacity upto 3000 LPH, pressure 12 Kg/Sqcm, MOC Cellulose Polyamide, of Filteration grade 97-98% Salt Rejection of Size 8040 complete with pressure vessels, RO membrane connectors etc Make : Toray/LG/ Hydranautics
S&F in repair Bag filter 4" x 20", type multimedia filter, filtration grade - 5 micron, flow rate not less than 3000 Ltrs / Hr, complete as directed of make Aqualux / Ion exchange / Aqua.
Supply and fix in repairs Cartridge Filter Online wound type of size 2.5" Dia x 20" long, Pressure 3.5 - 4.0Kg/Sqcm, MOC : PP, Filteration Grade 20 Microns, capacity 2.0m3/hr complete.
Dismantling of defective centrifugal pump set of RO plant , of any make/Model for repairing and reassembling including replacement of defective spare parts by new one of capacity of 1/1.5/2 HP pump set including required MS stud with nuts and bolts etc all as required. Note: (i) Spare parts of the centrifugal pump sets shall be measured and paid separately under relavent item of schedule. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop.
M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 1/1.5 HP Motor.
M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 2HP Motor.
Supply only suitable size bearing for induction motor of 1/1.5/2 HP , after taking out old unservicable complete all as specified and directed at site etc.
Disconnecting and taking down old PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 20 mm dia pipe complete all as specified and directed.
All as per item No. 84 here in above but 25 mm dia pipe.
All as per item No.84 here in above but 40 mm dia pipe.
All as per item No. 84 here in above but 50 mm dia pipe.
All as per item No. 84 here in above but 80 mm dia pipe.
Supply and Fixing in any length UPVC pipe 20 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed
All as per item No. 89 here in above but size (25 mm dia).
All as per item No. 89 here in above but size (40 mm dia).
All as per item No. 89 here in above but size (50 mm dia).
All as per item No. 89 here in above but size (80 mm dia).
S & F in repair UPVC Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes all as specified and as directed.
All as per item No. 94 here in above but of size (25 mm dia).
All as per item No. 94 here in above but of size (50 mm dia).
All as per item No. 94 here in above but of size (80 mm dia).
Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge.
Rentring filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge.
Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall as specified.
Testing of water for physical bacteriogical analyisi as per standared/IS cod test from any govt approved recognized lab or NABL approved lab or approved by the GE sample should be collected by Ref of lab.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply, erecting and fixing in true vertical position, Prestressed cement concrete pole 9 mtr long confirming to IS-1678 (latest) with minimum cross sectional area 102 mm x 152 mm at top and 102 mm x 289 mm at bottom , class - 10 with and Including all necessary excavation & earth work in any type of soil for foundation of poles, PCC of 150mm thickness 1:3:6 type (C-2) (using 40 mm graded stone aggregate ) in foundations of size 1.20 m X 0.60 m X 1.65 m below GL, PCC 1:2:4 type (B- 1 )(using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete( M&L)all as specified and directed. (Note -SSR part I clause No.19.5 & 19.52 and other relevant clauses of SSR refers for execution of work and poles shall be procured directly from the manufacturer mentioned in tender documents.)
Supply and fixing in replacement old rusted street light bracket, clamps, nuts and bolt with new street light bracket made out of 25 mm dia medium grade GI pipe (length of pipe should not be less than 2 mtrs) , two set of clamp flat iron, nuts & bolts as required , bend to shape and fixing arrangement duly welded complete all as directed.
Supply and fixing in replacement old unserveceable cable junction box with new pole mounted thermoplastic cable junction box for street light with IP-65 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed .
M&L for twin core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable (for phase and neutral) of size 2.50 Sqmm for connection drawing through pole or GI brackets of street light fittings to junction box complete all as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 2 core 10 Sqmm laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
Comprehensive maintenance of DG sets of capcity 62.5 KVA for routine/preventive maintenance, checking up of Engine and Alternator, AMF panel for smooth functioning and attending breakdowns/ complaints as and when required for smooth functioning of DG Set. The type of work/maintenance services to be carried out during comprehensive maintenance are as under:- (a) Cleaning of air filter (b) Checking and adjusting of valve tappet clearance (c) Checking of Engine lubrication system, fuel system, air system, cooling system, mechanical adjustments/rectification and electrical system. (d) Changing of lube oil filter if necessary (e) Changing/cleaning of fuel pre & fine filter (f) Checking and tightening of bolts and nuts (g) Checking of flexible rubber coupling (h) Checking of charging system of the battery. (i) Checking of ‘V’ belt and adjusting the tension (j) Checking of exhaust turbo charger (k) Checking of fuel injector (l) Checking and cleaning of breather pipe (m) Checking of alternator terminals and cable lighteners etc (n) Checking of safety controls operation (o) Checking of speed governors and engine shut down for proper functioning. (p) Checking of proper functioning of self starter and provision and battery charging (q) Greasing of generator (r) Carrying out preventive maintenance, checking as per manufacturer’s recommendations and to make proper functioning/serviceability of u/s RPM meter and hour meter and all engine parameters, gauges throughout the CA period and if required replace with new one without any extra cost.
Supply only set of fuel pre-filters and fine filters as per sample and make of the 62.5 KVA capacities of DG sets for above said capacity
Supply only set of lub/engine oil filters/cartridges as per sample and make, of the 62.5KVA capacities of DG sets for above said capacity
Supply only main contactor for AMF panel model of 62.5 KVA DG set complete all as specified and directed
Supply only micro processed based PCB for AMF panel model of 62.5 KVA DG set complete all as specified and directed
Supply only Auxillary/control contactors (2 NO, 2 NC) of suitable ratings for AMF panels complete all as specified and directed
Supply only battery charger ie step down transformer) fo ratings 100 VA 220-240V/12-14-16 Voltssuitable for AMF panels complete all as specified and directed
Material and labour for radiator anticorrosive coolent conditioner properly mixed up with the radiator water complete all as specified and directed.
Material and labour for lubricant oil for diesel generating set of any capacity and any make complete all as specified and directed by Accepting officer
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
- ditto- here in before Item 129 but of size 3.5 core 35 Sqmm
- ditto- here in before Item 129 but of size 3.5 core 50 Sqmm
Material and labour for bring the van mounted full automated underground cable fault locator machine at site for find out HT/LT cable fault in underground completely all as specified and directed by Engineer in Charge. Note: (a) Fault machine,cable & T&P required shall be arranged by the contractor.
MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 63 Amps 16 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 100 Amps 16 KA.
Testing of lightning conductor earthing with the help of earth tester in presence of users rep presventative and recording the earth results in test register and contractor should submit result on his own firm letter pad of each sub depot and MES register duly signed by OC of sub depot jointly signed by MES and users rap complete all as directed by EIC
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 6 Sqmm.
M&L for refreshing of incomming and all outgoing XLPE cable of any size including excavation for removing cable loop , refreshing of exsiting all cable by removing insulation ,cleaning of panel inside and ouside ,including removing old damaged lugs and fixing of suitable size lugs, PVC conncetor,dressing of all cables . nuts ,bolts,washer to all incomming and outgoing MCCB , insulating all bare conductor with insulating cable of suitable colour all as sepcfiedc and directed by Engineer-in-charge.
Dismantling and taking out of old existing unserviceable insulators of any description and in any position from LT poles complete all as specified and as directed.
S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts grade for LT lines fixed on poles complete all as specified and as directed.
S & F Flourish black 15W colour water prrof classy and smart look bollard gate light for garden, outdoor type with PCC chamber and necessary excavation complete all as specified and directed.
S&F 3 core 1.5sqmm PVC cable including conduit of size 20mm complete all as specified and directed
supply amd fix post top lantern with polycarbonate cover 40W, anti corrosive surface treatment complete all as specified and directed
Supply and fix pole mounted automatic street light timer panel astronomical made up of suitable size CRCA sheet panel with input voltage of 130 to 250V power failur memory backup and load upto 5KW all as specfied and directd
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
suvidhiconstruction
Nirmal Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .