| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | ₹35.2 L Quoted ₹35.3 L | L1 | Accepted-AOC LOWEST TENDER |
| 2 | L2₹36.5 L+₹1.2 L (3.44%)Rejected-Finance NEAR NEELAMMA VEPACHETTU ASSAM GARDENS VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | ₹36.5 L+₹1.2 L (3.44%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹36.6 L+₹1.3 L (3.75%)Rejected-Finance | ₹36.6 L+₹1.3 L (3.75%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹37.8 L+₹2.5 L (7.09%)Rejected-Finance DOOR NO 58 1 236 6 FLAT NO A 104 SAMPATH ENCLAVE NAD KOTHA ROAD VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | ₹37.8 L+₹2.5 L (7.09%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹45.0 L+₹9.7 L (27.4%)Rejected-Finance | ₹45.0 L+₹9.7 L (27.4%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
5 Feb 2020, 6:00 pmClosed
GE UTILITY II VISAKHAPATNAM
GE UTILITY II 104 Area Industrial Estate Post Visakhapatnam 530007
MANNING OPERATION AND MAINTENANCE OF CENTRAL AC PLANTS AT MO(V) INCLUDING CERTAIN MISC E/M WORKS UNDER AGE E/M NO.I OF GE (UTILITY-II) VISAKHAPATNAM
2019_MES_283074_1
8670
Open Tender
Electrical Maintenance Service
Item Rate
330 days
GE UTILITY II VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY II VISAKHAPATNAM
₹96,000
Yes
15 Feb 2020
9 Jan 2020
6 Feb 2020
9 Jan 2020
5 Feb 2020
31 Jan 2020
Amount
Out sourcing of services for manning and operation of 04 Nos central air conditioning plants of capacity 3 X 135 TR, 3x31.75 TR, 3x30 TR, 3X24 TR water cooled AC Plants complete including cooling tower, AHUs, electrical control panels, pumps and connected equipments etc., complete of the chilled water type AC system, round the clock in 3 shifts of 08 hrs each including sundays and holidays complete all as specified and as directed.
Manpower:- Skilled Operator of trained and experienced in AC Plant Operating system - 01 No per shift for each plant (Total 04 Plants) Plant 1 :- 3 X 135 TR Plant 2 :- 3 X 31.75 TR Plant 3 :- 3 X 30 TR Plant 4 :- 3 X 24 TR Skilled Operator Total - 04 persons per Shift Note:- (i) The operator ensure the smooth operation and maintenance of the AC plants. (ii) Maintaining the hourly parameters Log book for the AC plant. (iii) Operation of DG sets and maintaining the Log book for DG sets. (iv) The operator ensure the smooth operation and maintenance of the DG Sets. (v) Operator must have skill to rectify minor repairs like gasket change, replacement of fuse cutouts etc., complete In case of any faults to put the plant on working condition.
(vi) The operator should be in a position to intimate major defects/ repairs immediately to the concern JE / Engineer-in-Charge. (vii) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge. (viii) One emergency light and necessary tools should be available in a tool box with operator for smooth functioning.
Out sourcing of services for manning and operation of 03 Nos central air conditioning plants of capacity 3 X 135 TR, 3x31.75 TR, 3x30 TR and 3x24 TR water cooled AC Plants complete including cooling tower, AHUs, electrical control panels, and pumps and connected equipments in complete of the AC system, round the clock in 3 shifts of 08 hrs each including sundays and holidays complete all as specified and as directed.
Manpower:- One Helper (un-skilled) for all the three plants in three shifts of 08 Hrs. Note:- (i) Taking care of house keeping environmental cleanliness area all around installation shall be kept absolutely neat and clean. Cost of all consumable stores such as brooms, cotton waste, cutters etc., deemed to be included in quoted rate. (ii) The Helper should be able to assist all the operators in general shift after keeping the plants clean & tidy. (iii) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Supply and replace LED street light fitting of 45 Watt capacity with IP66 protection inlcuding electronic driver and accessories suitable for pole dia upto 40 mm including GI bracket made of 40 mm gia Gi pipe light grade of length not less than 1.2metre bend to shape as reuired including necessary MS clamps, bolts, nuts, duly painted with 2 coats of synthetic enamel paint over a coat of primer complete all as directed by Engineer-in-charge. Make: CAT No. SLE UL 45W IP 66 LXN of Surya Roshini or its equivalent in Philips/ Havells India Ltd/ Wipro/ GE/ Bajaj.
Supply and replace existing pressure guage 4" dial, 0-14 Kg rating of existing make complete all as directed by Engr-in-charge. Make: H-Guard/ FIEBIG
Supply and replace existing pressure guage 4" dial, 0-21 Kg rating of existing make complete all as directed by Engr-in-charge. Make: H-Guard/ FIEBIG
Supply and replace MCCB 4 pole 100 Amps with rupturing capacity 16 KA (adjustable type) complete all as specified and directed.
Supply and replace MCCB 3 pole 160 Amps with rupturing capacity 36 KA (microprocessor release) complete all as specified and directed.
Supply and replace MCCB 4 pole 250 Amps with rupturing capacity 36 KA (microprocessor release) complete all as specified and directed.
Supply and replace MCCB 4 pole 400 Amps with rupturing capacity 36 KA (microprocessor release) complete all as specified and directed.
Supply and install gaseous type gravity feed chlorinator of capacity upto 2 KG/hour chemical grade panel board 6 mm thick 2' X4', mounted consisting of flow meter, PVC primary filter, safety guage , teflon pipe 5RM, U-bend, secondary filter with NRV, gas bend with glass NRV, water chlorine mixing chamber water TEE along with inlet and outlet vlave solutioniser water bend complete all as specified and directed. Make: Sathya Sai or its equivalent as approved by GE.
Supply, laying XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 16 Sq mm including taking out old un-serviceable cable complete all as specified and directed.
All as per Sl. Item No.11 above but 4 Core 25 Sqmm
All as per Sl. Item No.11 above but 3.5 Core 35 Sqmm
All as per Sl. Item No.11 above but 3.5 Core 50 Sqmm
M&L Point wiring complete with PVC insulated unsheathed cable 1100 Volts grade conforming to IS-694 - 1990, 1.5 Sqmm (nominal area) multi-stranded with copper conductor drawn through and including non metallic rigid 20 mm dia PVC conduit including accessories medium grade of minimum 20 mm dia (ISI marked) and conduit accessories, surface type with sunken type, provision of PVC insulated unsheathed 1.5 Sqmm standard copper conductor as earth continuity conductor and connecting to common earth dolly and including taking down existing wiring with fittings / fixtures such as switches, sockets, ceiling roses, pendants, regulators, lamp holders, light fittings etc, for one light/fan/ controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per Sl. item No.15 above but for one 3 pin 5 amps socket controlled by one switch on independent board
All as per Sl. item No. 15 above but for one 3 pin 5 amps socket controlled by one switch on same board
All as per Sl. item No.15 above but wiring with 2.5 sqmm and earth wire 2.5 Sqmm unsheathed single core PVC insulated multistranded copper conductor for 3 pin 15 Amps socket outlet
S&F switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal 230 volts complete all as specified and directed by Engr-in-Charge.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp, 15 Amps flush type universal 230 volts complete all as specified and directed by Engr-in-Charge.
M&L ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and directed by Engr-in-Charge.
Supply and fix electronic type speed variable/step type fan regulator 230 volt, AC complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC board of size 30 x 25x 5 cm ISI marked complete complete all as specified and directed. Make: Presto Plat/ Presto Teak/ MODI/ Plaza
Supply and replace sheet metal enclosure single pole and neutral , 240 volts, 4 way double door with 200 Amps rated bus bar complete all as specified and directed.
Supply and replace sheet metal enclosure single pole and neutral , 240 volts, 8 way double door with 200 Amps rated bus bar complete all as specified and directed.
Supply and replace MCB SP, 'C' curve 6 to 32 Amps complete all as specified and directed.
Supply and replace MCB SPN, 'C' curve 6 to 32 Amps complete all as specified and directed.
Supply and Fixing wall mounted slim LED batten with extruded aluminium housing with integrated LED driver with LED tube including removing existing unserviceable one complete all as directed. Make: CAT No. SLE BT 20 18W of Surya Roshini Ltd or its equivalent in Philips/ Havells India Ltd/ Wipro/ GE/ Bajaj as approved by GE.
M&L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point and including taking down existing earthing complete all as specified or indicated including testing on completion all as specified and directed by Engineer-in-charge: NOTE: The quoted rate shall deemed to be included for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:2:4, type B1 cover 50 mm thick with 8 mm dia TMT bar @ 140 mm C/C, GI watering pipe 20 mm bore medium grade, funnel, wire mesh and earthing lead upto 7.5 m.
Supply and replace 300 mm bore CI sluice valves PN 1.6 (Raising type) conforming to IS 14846 flanged end with iron wheel head and stainless steel spindle flanged joints including necessary nuts, bolts, and washers etc., complete all as specified and directed.
All as per SL item No.31 above but of size 250 mm dia.
All as per SL item No.31 above but of size 200 mm dia.
Supply and replace 250 mm bore CI foot valve flanged type with necessary rubber gasket, bolts, nuts and washers complete all specified and directed.
All as per SL item No.34 above but of size 200 mm dia.
All as per SL item No.34 above but of size 150 mm dia.
M&L for sub-main wiring with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm, 1100 volts grade, including non metallic rigid 20 mm dia PVC conduit with all fitting and fixing accessories and including one run of PVC insulated unsheathed, multistranded copper conductor cable of size 4 sqmm for earth continuity conductor and including taking down old unserviceable sub main wiring complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as unit length.
M&L for sub-main wiring with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 6 sqmm, 1100 volts grade, including non metallic rigid 20 mm dia PVC conduit with all fitting and fixing accessories and including one run of PVC insulated unsheathed, multistranded copper conductor cable of size 6 sqmm for earth continuity conductor and including taking down old unserviceable sub main wiring complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as unit length.
Supply and replace Electro Magnetic Flow Meter 400 mm Make :- Eureka, Model No EUMAG-400-N-S-1MODBUS-CS -R10 -D16-230-M , Fluid ; water, op , pressure ;-16 Bar , Range : 0-600 m3/hr , Lining : hard rubber ,Electrodes : SS316, Flanges CS , connection ; 400 NB DIN PN 16 ,Accuracy +/- 0.5 % of the Flow rate (between 0.5 -10m/s velocity), Display 16 X2 backlight LCD for flow rate & total flow , Out put 4 -20 Ma + RS485, supply voltage ; 230 V AC , 50 HZ , protection class for convertor unit -IP -68 ,Flow tube material of construction (MOC) - SS304 , Transmitter & Display Indicator will be remote type provided with 10 meter cable RS485 protocol will be provided , with flange class PN 16 suitable for pressure 16 bar, with empty pipe Indication complete all as specified and as directed by Engineer-in-Charge.
M&L for Sheet metal enclosure for LT panel of size 1250 x 800 x 600 mm outdoor type made out of 3.15 mm thick CRCA Sheet, including MS angle iron frame with weather proof canopy, Bus bar of rating 630 Amps of size 40/10 copper bus bar, mounted on suitable size foundation (PCC 1:3:6 type C1) pedestal, Cubical type, front and rear side openable, compartment type with hinged door and locking arrangement for each compartment, provision of air vent, dust and vermin proof duly painted with 2 coats powder coating over a coat of anti corrosive red oxide primer with and including change over 630 Amps accessories are in built in with Panel board complete all as directed by Engineer-in-Charge:-
Bhuvaneswari Electrical Works
M/s Chandu Lavanya Engineers Contrctors
M/S EVEREST INFRA
LAKSHMI SAI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .