Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC SADAR PARA PS PURULIA T DIST PURULIA PIN 723101 W B | PURULIA | PURULIA | WEST BENGAL | 723101 | L1 | Accepted-AOC M/S RAHUL TRADERS IS THE LOWEST BIDDER | |
| 2 | L2₹8.1 L+₹15,300 (1.92%)Rejected-Finance VILL ABASH CHOTO BARDIA GRAM ABASH P S KOTWALI ABASH 721102 | MEDINIPUR WEST | WEST BENGAL | 721102 | L2 | Rejected-Finance MS RAHUAL TRADERS IS THE LOWEST BIDDER AS PER QUOTED RATE | |
| 3 | L3₹8.2 L+₹26,530 (3.32%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance MS RAHUAL TRADERS IS THE LOWEST BIDDER AS PER QUOTED RATE |
Tender Value
₹8.2 L
EMD Value
₹16,459
Closing Date
25 Mar 2024, 4:00 pmClosed
Divisional Manager, Raghunathpur Division
DIVISIONAL OFFICE RAGHUNATHPUR WBSEDCL ADRA ROAD RAGHUNATHPUR PURULIA 723133
Electrical Installation and concealed wiring work for newly constructed Office Building of Hura CCC under Raghunathpur Division
2024_WBSED_683681_1
DM/RNPD/TENDER/23-24/13 Dt. 11.03.2024
Open Tender
Miscellaneous Services
Item Rate
180 days
Lalpur Hura
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹16,459
Raghunathpur Division
14 May 2025
11 Mar 2024
28 Mar 2024
12 Mar 2024
25 Mar 2024
12 Mar 2024
15 Mar 2024
Amount
Supplying and fixing of double door Vertical TPN MCB Distribution Board (Make: Legrand) 12 way, upto 160 A for MCCB incomer with IP-42/43 protection…….. With suitable size of copper wire and neutral link and provision of earth attachment as per [PWD/GS-2017 Page No.: D11 Item No.: 15]
Laying of cable from Control Panel to Pump Starter Panel (including freight, insurances, incidental charges etc as applicable) 3C x 4 Sq.mm. PVC Insulated Aluminum flat cable in 20mm G.I Conduit with necessary earthling by 2 X 1.5 sq.mm. copper wire.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc. as applicable) TPN Distribution Box, 250 V 06 - 32 Amp per way, TPN MCB with SS enclosure Single door with IP 42/43 protection with four Isolators as incomer and SPMCBs (‘C’ Curve, 10 kA) as outgoing on wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link and provision for earthing attachment (Havell’s make) as follows. i) DB Box: HAVELL, Make "Single Door with Acrylic Window DB for 6/4 way Cat.Code: DHDPTHOSRW06/ DHDPTHOSRW04. ii) Incomer MCB: HAVELL,Make TPN MCB 63 A/ 32 A rated for incomer,Cat. Code: DHMCCTNF063/ DHMCCTNF032-1 no. iii) Outgoing MCB: HAVELL,Make SP MCB 16-32 A rated for outgoing,Cat. Code: DHMCCSPF006-032)- 18 nos./12 nos. iv) Supply & Fixing of Name plate. 6 way DB : (Ground Floor-02 nos./ 1st Floor-02 nos.)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc as applicable) 6 way TPN Distribution Box for UPS Power distribution, 250 V 06 - 32 Amp per way, TPN MCB with SS enclosure Single door with IP 42/43 protection with four Isolators as incomer and SPMCBs (‘C’ Curve, 10 kA) as outgoing on wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link and provision for earthing attachment (Havell’s make) as follows. i) DB Box: HAVELL, Make "Single Door with Acrylic Window DB for 6 way ,Cat.Code: DHDPTHOSRW06.-1 no. i) Incomer MCB: HAVELL,Make TPN MCB 63 A rated for incomer,Cat. Code: DHMCCTNF063- 1no. ii) Outgoing MCB: HAVELL,Make SP MCB 16-32 A rated for outgoing,Cat. Code: DHMCCSPF006-032)- 18 nos. ii) Supply & Fixing of Name plate. 6 way DB : (First Floor) & (Ground Floor)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges, Taxes etc as applicable) 6 way TPN Distribution Box for UPS Power distribution, 250 V 06 - 32 Amp per way, TPN MCB with SS enclosure Single door with IP 42/43 protection with four Isolators as incomer and SPMCBs (‘C’ Curve, 10 kA) as outgoing on wall and mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link and provision for earthing attachment (Havell’s make) as follows. i) DB Box: HAVELL, Make "Single Door with Acrylic Window DB for 4 way ,Cat.Code: DHDPTHOSRW04.-1 no. i) Incomer MCB: HAVELL,Make TPN MCB 63 A rated for incomer,Cat. Code: DHMCCTNF063- 1no. ii) Outgoing MCB: HAVELL,Make SP MCB 16-32 A rated for outgoing,Cat. Code: DHMCCSPF006-032)- 12 nos. ii) Supply & Fixing of Name plate. 4 way DB : (Ground Floor)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Havells make 40A ONLINE Change Over switch with enclose (Cat. Code: IHCNFE0040) for UPS interconnection at ground floor
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) from Bas Bar to I/C UPS DB and O/G UPS DB to UPS DB interconnection and upto Ac Starter distribution wiring of 2x56/0.3 (4 sqmm) + 1x22/0.3 (2.5 sqmm) ECC (Brand as aprroved by the Supervising Officer) [PWD/GS-2017 Page No.: E11 Item No.: D-1(e)](Conceal Wiring)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Distribution wiring from Busbar to D.B of 3x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) ECC (Brand as aprroved by the Supervising Officer)from Bas Bar Panel to TPN DB. As per [PWD/GS-2017 Page No.: E14 Item No.: E-1(b)(iv)] and [PWD/GS-2017 Page No.: E16 Item No.: E-7(b)] etc. as follows. (Conceal Wiring) Ground Floor : 2 nos. Light DB and 1 no. UPS DB 1st Floor : 2 nos. Light DB X 1 no. UPS DB
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Distribution wiring in 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) ECC (Brand as aprroved by the Supervising Officer)from LDB to Switch Board. [PWD/GS-2017 Page No.: E11 Item No.: D-1(c)](Conceal Wiring) Ground Floor : 11 nos. switch Board 1st Floor : 9 nos. switch Board
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Distribution wiring in 1.1 KV grade single core 2C x 4 Sq.mm. ‘FR’ PVC insulated & unsheathed copper wire (Havell’s make) in suitable size Rigid PVC Pipe (Precision make) with 1.5 sq.mm. single core standard ‘FR’ PVC insulated & unsheathed copper wire for ECC incl. necy. PVC clips, fittings etc. A.C. point. As per [PWD/GS-2017 Page No.: E11 Item No.: D-1(d)] (Conceal Wiring) 1st Floor : 1 no. - 50 mtrs.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Distribution wiring in 1.1 KV grade single core 2C x 2.5 Sq.mm. ‘FR’ PVC insulated & unsheathed copper wire (Havell’s make) in suitable size Rigid PVC Pipe (Precision make) with 1.5 sq.mm.single core standard ‘FR’ PVC insulated & unsheathed copper wire for ECC incl. necy. PVC clips, fittings etc. to 15 A 3 pin Power point (From DB to Power point). As per [PWD/GS-2017 Page No.: E11 Item No.: D-1(c)] (Conceal Wiring) Ground Floor : 6 nos. Power Point 1st Floor : 11 no. Power Point
Supplying & fixing 240 V two 5 Pin 16 A, 3 pin Modular type plug socket with one no. 16 A modular type (Brand approved by EIC) switch without plug top... ................ [Power Point without ckt run] [PWD/GS-2017 Page No.: E18 Item No.: 9(b) ]
Earthing with 80mm dia GI pipe (TATA Medium)................................and partly above ground level to an averege depth of 3.65 mtrs. With necessary soil treatment and masontary treatment as per PWD/GS Page No.: G-1 Item No.: 2/e, PWD/GS Page No.: G-2 Item No.: 3/a and 3/b for VTPN as per PWD/GS Page No.: G-1 Item No.: 2/e, PWD/GS Page No.: G-2 Item No.: 3/a and 3/b
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Gate light ,laying of 2 core 2.5 sq.mm. Copper Cable with 20 mm size Rigid conduit ‘FR” on wall with MS saddles with earthing arrangement in 1 X 1.5 sq.mm. copper wire, making hole etc., as necessary mending good damages and painting with GI pipe dia 25 mm 6 mtr long for approach road crossing as per PWD/GS-2017 Page No.: E14 Item No.: E(1)(a)(ii)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) Area light from roof ,laying of 2 core 2.5 sq.mm. CU Cable through conceal wiring with earthing arrangement in 1 x 1.5 sq.mm. copper wire, making hole etc., as necessary mending good damages and painting. as per PWD/GS-2017 Page No.: E1 Item No.: A(1)(b)
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) outdoor type MH/SV/Fluorescent light fittings on building wall including S & F 40 mm dia x 1.68 long GI pipe (ISI medium) bracket with 40 mm x 10 mm thick , MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated & sheathed wire (single core) in GI conduit incl. making connections with terminals connector and painting. As per PWD/GS-2017 18 of page C3.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) for single phase 240/250 V , A.C. 50 Hz. 6 AMP, 5 Pin Plug socket with switch Modular (Havell’s) including Modular Switch Board. As follows 12 Modular Box – 1 No. 6 AMP Modular Switch. 4 No. 6 AMP Modular Socket. 4 No. Ground Floor: Computer UPS Point: 6 Nos. 1st Floor: Computer UPS Point: 11 Nos.
Supply, delivery, fittings, fixing and electrical connection of (including freight, insurances, incidental charges etc, as applicable) UPS light points with bottom holder on PVC Junctions box (ISI marked) suitable for functioning / distribution wing operating from normal switch board. (Brand as approved by EIC) as per PWD/GS Page No.: E-21 Item No.: H(1)(b) Ground Floor: Emergency Light Point: 3 Nos. Emergency Light Point- Stair Case: 1 Nos. 1st Floor: Emergency Light Point : 4 Nos.
Distribution wiring in 1.1 kv grade 2x1.5 sq.mm. single core standard FR PVC insulated copper wire Havell’s make through conceal wiring with. necessary fittings etc. to light/fan points with modular PVC box & 6 Amp switch, socket (Brand as approved by EIC) including necessary connection as required. as per PWD/GS-2017 Page No.: E-21 Item No.: H(1)(d)
A.C. Points. and Router Point Supplying & fixing 240 V, 25A Modular type socket, 25A Modular type starter (Brand approved by EIC) with 25 A Modular type DP MCB (C Curve) .............. ................ with necessary connection with PVC Cu wire and earth continuty wire etc. [Power Point without ckt run for AC] [PWD/GS-2017 Page No.: E19 Item No.: 18 ]
Supply and Delivery & Fixing of electrical appliances on Alluminium surfaced/Wall/ (Make Havells/ Crompton Greaves) as per specifications and scope of the work LED Double Side Tube Light Set 18 watt
Supply, Delivery and fixing of electrical appliances of Make Havells/ Crompton Greaves as per specifications and scope of the work Panel SURFACE Celling Light 24 watt LED in surface/False ceiling with dimension 295X295X70 mm and system Luminous Efficiency greater than 80 lm/w.
Supply,Delivery & Fixing of electrical appliances of Make Havells/ Crompton Greaves as per specifications and scope of the work CELLING FAN 48''*1200 MM LONG-SS-390 with Down rod, Canopy frock and Blades etc and necessary connection making by Twin core copper wire with Electronic Regulator (Make Anchor& Crabtree)
Supply,Delivery & Fixing of electrical appliances of Make Havells/ Crompton Greaves as per specifications and scope of the work of10Watt LED bulb.
Supply, delivary and fixing of Gate light 25 watt LED post light
Supply and delivary of Havell's make LED Yard light 150 watt (Cat. Code: JETAIRS150).
Supplying & fixing M.S. Angle on the CCC Building for the Yard Light and necessary connection from Loop Box with PVC Conduit pipe, PVC wire, saddles, clamps, nut & bolts and necessary earthing arrangement. As per PWD schedule 19 of page C3.
Supply,Delivery and Fixing of electrical appliances of Make Havells/ Crompton Greaves as per specifications and scope of the workExaust Fan 9''-DBB with Fixing of louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For 23 cm (9") Exhaust fan.
Supply and Fixing of cabin fan (Make Havells/Crompton Greaves )on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. Length.
> Lightning Arrestor: Supply, delivery, fittings, fixing (including freight, insurances, incidental charges, Taxes , Duties, Cess etc, as applicable) of Lightning Arrestor Arrangement of the CCC Building- Hura with necessary earth continuity and inter connection through parapet wall.
> Earth Pit: Earthing with 80mm dia GI pipe (TATA Medium)......... ..........and partlyabove ground level to an averege depth of 3.65 mtrs. With necessary soil treatment and masontary treatment as per PWD/GS-2017 Page No.: G-1 Item No.: 2/e, PWD/GS-2017 Page No.: G-2 Item No.: 3/a and 3/b for Electrical Panel and Busbar Panel.
>Earth Continuity: Earth continuity from each lighting arrestor to earth pit and inter connection between the Earth Pits/ Lightning Arrestor including S&F 25x6 mm galvanised (Hot Dip) MS flat on wall/ parapet with GI saddles as required with drilling holes, bolts, nuts, washers etc. As per PWD/GS-2017 Page No.: G-2 Item No.: 3/a.
Supply and fixing of D'Link make I/O box of LAN connection ( Cat. Code NBB011 and NFP-OWHI11) on the wall with screws and other fixing materials including making necessary holes and connections.
Supply anf fixing of polythine pipe for LAN cable....................... as per PWD/GS-2017 Page No.: E2 Item No.: 1(C) ]
Supply & drawing of LAN cable (CAT6) (Brand as approved by Supervising Officer) Of existing PVC board ................................... as per PWD/GS-2017 Page No.: E19 Item No.: 21 ]
Supply & fixing of Modulalar type RJ45 suitable for CAT LAN cable (Brand as approved by Supervising Officer) o existing PVC board ................................... as per PWD/GS-2017 Page No.: E18 Item No.: 7(a) ]
SREE LALJI
TARUN DEY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .