Annual Maintenance Contract of Auto Change over Control and Distribution panel (CLS Panel) over Katihar division for two Years.
36_2026
36_2026
Open
24 Months
Katihar, Bihar
₹0
₹1.0 L
20 Jun 2026
20 Jun 2026
2 Jul 2026
B-Schedule-B (Spare parts for 2 year)
C-Schedule-C (Different size cable used for CLS panel)
Item Breakup - A-Schedule-A
"Annual maintenance charges per CLS panel (for Numbers 141.00 regular inspection / cleaning / Diagnosis of defects / minor repair with following spares) (Unit Rate is per CLS per year)." (A) 1st Year
(B) 2nd year Total 549900.00
Item Breakup - B-Schedule-B (Spare parts for 2 year)
Rotary Selector Switch (A) 4 Pole, 6 way, 240 V Numbers AC, 50 Hz, 30 A (for AT rating 5 KVA)
(B) 4 Pole, 6 way, 240 V AC, 50 Hz, 60 A (for AT Numbers Rating 10 KVA)
(C) 4 Pole, 6 way, 240 V AC, 50 Hz, 150 A (for AT Numbers Rating 25 KVA)
(D) 4 Pole, 6 way, 240 V AC, 50 Hz, 300 A (for AT Numbers Rating 50 KVA)
Air Break Contactors (a) "2 or 3 Pole, 30 Amp, AC- Numbers 3 duty with 2 NO and 2 NC (or 3 NC) auxiliary contacts working on 240V AC, 50Hz (for AT rating 5 KVA) "
(b) 2 or 3 Pole, 60 Amp or 63 Amp, AC-3 duty with Numbers 2 NO and 2 NC (or 3 NC) auxiliary contacts working on 240V AC, 50Hz (for AT rating 10 KVA)"
(c) 2 or 3 Pole, 150 Amp, AC-3 duty with 2 NO and Numbers 2 NC (or 3 NC) auxiliary contacts working on 240V AC, 50Hz (for AT rating 25 KVA)
(d) 2 or 3 Pole, 300 or 315 Amp, AC-3 duty with 2 Numbers NO and 2 NC (or 3 NC) auxiliary contacts working on 240V AC, 50Hz (for AT rating 50 KVA)
Isolator Switch (a) 2 Pole, 30 Amp, working on Numbers 240V AC, 50Hz (for AT rating 5 KVA)
( b ) 2 Pole, 60 Amp, working on 240V AC, 50Hz Numbers (for AT rating 10 KVA)
(c) 2 Pole, 150 Amp, working on 240V AC, 50Hz Numbers (for AT rating 25 KVA)
(d) 2 Pole, 300 Amp, working on 240V AC, 50Hz Numbers (for AT rating 50 KVA)
MCB or MCCB (Input and output side) (a) 2 Pole, 6 Numbers Amp, working on 240V AC, 50Hz (for AT rating 5 / 10 / 25 / 50 KVA)
( b ) 2 Pole, 10 Amp, working on 240V AC, 50Hz Numbers (for AT rating 5 / 10 / 25 / 50 KVA)
(c) 2 Pole, 25 Amp, working on 240V AC, 50Hz Numbers (for AT rating 5 / 10 / 25 / 50 KVA)
( d ) 2 Pole, 32 Amp, working on 240V AC, 50Hz Numbers (for AT rating 5 / 10 / 25 / 50 KVA)
( e ) 2 Pole, 50 Amp, working on 240V AC, 50Hz Numbers (for AT rating 5 / 10 / 25 / 50 KVA)
(f) 2 Pole, 63 Amp, working on 240V AC, 50Hz (for Numbers AT rating 10 / 25 / 50 KVA)
(g) 2 Pole, 150 Amp, working on 240V AC, 50Hz Numbers (for AT rating 25 KVA)
(h) 2 Pole, 315 Amp, working on 240V AC, 50Hz Numbers (for AT rating 50 KVA)
LED indication, 22.5 mm dia (for incoming, Numbers 882.00 Outgoing and active source)
Alarm buzzer, 240V AC, 50 Hz
Alarm reset micro switch/Push button
10 Watt LED Lamp, 240V AC
PCB Card (Control card/module), microcontroller Numbers 100.00 type suitable for all Control and Distribution panel (CLS Panel) 30A/60A/150A/300A Total 4232978.00
Item Breakup - C-Schedule-C (Different size cable used for CLS panel)
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway) Total 396000.00