Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC B71 AKSHAY MITTAL INDUSTRIAL CO OPERATIVE SOCIETY BUILDING NO 5 ANDHERI KURLA ROAD MAROL MAROL ANDHERI EAST MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.6 L+₹8.3 L (358.0%)Rejected-AOC 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.5 L+₹22.2 L (961.3%)Rejected-AOC | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | AFFORD MARINE CONTROLS PVT.LTD L1 | SMEC AUTOMATION PRIVATE LIMITED L2 | AKSHAY CONTROLS AND SYSTEMS PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 2.00Auxiliary and Exhaust Boilers jobs onboard the Vessel RM.0815, Oil fired | ||||||
| 3.00SERVICE PART | ||||||
| 4.00E 25028 : AUXILIARY AND EXHAUST BOILERS (SURVEY). | ||||||
| 5.00OIL FIRED AUX. BOILERS (1 NOS.) MAKE: KANGRIM TYPE 25000KG/HR 7 BAR OIL BURNER TYPE : STEAM ATOMISING OIL BURNER TYPE:-DF505 | ||||||
| 6.00 | E 20028. 7, ALL CUTOUTS & TRIPS TO BE TRIED OUT FOR SAFTY VALVES | 1 | LS | 12,000 ₹12,000 Lowest | 67,200 ₹67,200 | 50,000 ₹50,000 |
| 7.00 | E 20028. 35, 37. FD FAN DAMPER PNEUMATIC ACTUATOR OPERATION SLUGGISH SAME TO CHECK & DEFECT TO RECTIFY. AIR SUPPLY UNIT WITH REDUCING VALVE AND FILTER TO CHECK/REPAIR IF DEFECT NOTICED. PARTS REQUIRED TO BE QUOTED. | 1 | LS | 9,500 ₹9,500 Lowest | 43,200 ₹43,200 | 50,000 ₹50,000 |
| 8.00WATER LEVEL CONTROL SYSTEM FOR AUX. BLR. MAKER : KANGRIM HEAVY INDUSTRY CO. LTD. KOREA MODEL MB06S01 | ||||||
| 9.00 | E 20028. 55, AUX BOILERS WATER LEVEL TRANSMITTERS CONTROLLERS V/V POSITIONERS TO OVERHAUL AND CALIBRATE. | 1 | PCS | 3,750 ₹3,750 Lowest | 2,02,400 ₹2,02,400 | 60,000 ₹60,000 |
| 10.00 | E 20028. 56, 4.1) ONE NO. FEED WATER CONTROL V/VS TO OVERHAUL. | 1 | PCS | 4,250 ₹4,250 Lowest | 19,205 ₹19,205 | 40,000 ₹40,000 |
| 11.00 | E 20028. 57, 4.2) REMOTE LEVEL INDICATORS IN E.C.R. TO CHECK AND CALIBRATE. | 1 | PCS | 5,500 ₹5,500 Lowest | 6,250 ₹6,250 | 15,000 ₹15,000 |
Tender Value
Refer Docs
Closing Date
7 Jul 2025, 3:00 pmClosed
DGM SRM
Ship Repair Materials Department Cochin Shipyard LTD Perumanoor PO
AUXILIARY AND EXHAUST BOILERS JOBS ONBOARD THE VESSEL RM 0815
2025_CSL_239885_1
CSL/SR1/815/GePNIC/ADV/44020
Open Tender
Marine Services
Works
20 days
CSL KOCHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
23 Aug 2025
1 Jul 2025
8 Jul 2025
1 Jul 2025
7 Jul 2025
1 Jul 2025
1 Jul 2025 - 7 Jul 2025
Amount
Auxiliary and Exhaust Boilers jobs onboard the Vessel RM.0815, Oil fired
SERVICE PART
E 25028 : AUXILIARY AND EXHAUST BOILERS (SURVEY).
OIL FIRED AUX. BOILERS (1 NOS.) MAKE: KANGRIM TYPE 25000KG/HR 7 BAR OIL BURNER TYPE : STEAM ATOMISING OIL BURNER TYPE:-DF505
E 20028. 7, ALL CUTOUTS & TRIPS TO BE TRIED OUT FOR SAFTY VALVES
E 20028. 35, 37. FD FAN DAMPER PNEUMATIC ACTUATOR OPERATION SLUGGISH SAME TO CHECK & DEFECT TO RECTIFY. AIR SUPPLY UNIT WITH REDUCING VALVE AND FILTER TO CHECK/REPAIR IF DEFECT NOTICED. PARTS REQUIRED TO BE QUOTED.
WATER LEVEL CONTROL SYSTEM FOR AUX. BLR. MAKER : KANGRIM HEAVY INDUSTRY CO. LTD. KOREA MODEL MB06S01
E 20028. 55, AUX BOILERS WATER LEVEL TRANSMITTERS CONTROLLERS V/V POSITIONERS TO OVERHAUL AND CALIBRATE.
E 20028. 56, 4.1) ONE NO. FEED WATER CONTROL V/VS TO OVERHAUL.
E 20028. 57, 4.2) REMOTE LEVEL INDICATORS IN E.C.R. TO CHECK AND CALIBRATE.
E 20028. 58, 4.3) REMOTE /MANUAL OPERATION OF CONTROL V/V BY POTENTIOMETER TO CHECK.
E 20028. 59, 4.4) SATISFACTORY OPERATION OF SYSTEM IN AUTO & MANUAL MODE TO BE SHOWN TO CEO/SUPDT AFTER OVERHAULING.
COMBUSTION SYSTEM FOR OIL FIRED AUX. BOILERS.
E 20028. 60, 5.1) AUTO COMBUSTION CONTROL SYSTEM COMPLETELY TO BE SERVICED BY MAKERS SERVICE ENGINEER.OXYGEN CONTENT OF FLUE GASES TO BE ADJUSTED AT DIFFERENT LOAD CONDITIONS TO GIVE COLOURLESS SMOKE DISCHARGE & 2 TO 3 % OXYGEN CONTENT.
E 20028. 61, 5.2) AIR/OIL CONTROLLER FUEL OIL TEMP CONTROLLER AND MASTER PRESSURE CONTROLLER TO CHECK SERVICE AND SETTINGS TO ADJUST AS REQUIRED.
E 20028. 62, 5.3) FD FAN I.P. POSITIONER PNEAUMATIC ACTUATOR TO OVERHAUL & POSITIONER TO CONFIGURE AND INITILISED. F.D FAN LIMIT SWITCHES TO BE CALIBRATED.
E 20028. 63, 5.4) PLC BATTERIES TO CHECK AND RENEW AS REQUIRED.
E 20028. 64, 5.5) SATISFACTORY WORKING OF ABOVE SYSTEM IN AUTO & EMERGENCY MODES FOR BOTH AUX BOILERS TO BE SHOWN TO CEO/SUPDT.
E 25034 : CONTROL VALVES
FOLLOWING V/VS CONTROLLERS ACTUATORS POSITIONERS TO BE OVERHAULED CALIBRATED AND SATISFACTORY WORKING SHOWN TO CEO/SUPDT. SPARES IF ANY REQD. TO BE QUOTED. AA) TEMPERATURE CONTROL VALVES - MAKER KORVAL. E 20034. 10, 10) AUX BOILER F.O HEATER MODEL : KCR-DP PNEUMATIC DIAPHRAGM TYPE ACTUATOR MODEL NO : K03-R1 RANGE 0-150 DEG. BB) PRESSURE CONTROL V/VS - MAKER KORVAL
E 20034. 12, 12) EXCESS STEAM ( DUMP V/V )
E 25087 MISCELLANEOUS REPAIR JOBS
E25087.17, 15. AUX BOILER low low water level float gets punctured too often because of this low low water level trip doesn’t work . Same to be rectified using ships spare
MATERIAL PART
E 25028 : AUXILIARY AND EXHAUST BOILERS (SURVEY).
OIL FIRED AUX. BOILERS (1 NOS.) MAKE: KANGRIM TYPE 25000KG/HR 7 BAR OIL BURNER TYPE : STEAM ATOMISING OIL BURNER TYPE:-DF505
E 20028. 7, ALL CUTOUTS & TRIPS TO BE TRIED OUT FOR SAFTY VALVES
E 20028. 35, 37. FD FAN DAMPER PNEUMATIC ACTUATOR OPERATION SLUGGISH SAME TO CHECK & DEFECT TO RECTIFY. AIR SUPPLY UNIT WITH REDUCING VALVE AND FILTER TO CHECK/REPAIR IF DEFECT NOTICED. PARTS REQUIRED TO BE QUOTED.
WATER LEVEL CONTROL SYSTEM FOR AUX. BLR. MAKER : KANGRIM HEAVY INDUSTRY CO. LTD. KOREA MODEL MB06S01
E 20028. 55, AUX BOILERS WATER LEVEL TRANSMITTERS CONTROLLERS V/V POSITIONERS TO OVERHAUL AND CALIBRATE.
E 20028. 56, 4.1) ONE NO. FEED WATER CONTROL V/VS TO OVERHAUL.
E 20028. 57, 4.2) REMOTE LEVEL INDICATORS IN E.C.R. TO CHECK AND CALIBRATE.
E 20028. 58, 4.3) REMOTE /MANUAL OPERATION OF CONTROL V/V BY POTENTIOMETER TO CHECK.
E 20028. 59, 4.4) SATISFACTORY OPERATION OF SYSTEM IN AUTO & MANUAL MODE TO BE SHOWN TO CEO/SUPDT AFTER OVERHAULING.
COMBUSTION SYSTEM FOR OIL FIRED AUX. BOILERS.
E 20028. 60, 5.1) AUTO COMBUSTION CONTROL SYSTEM COMPLETELY TO BE SERVICED BY MAKERS SERVICE ENGINEER.OXYGEN CONTENT OF FLUE GASES TO BE ADJUSTED AT DIFFERENT LOAD CONDITIONS TO GIVE COLOURLESS SMOKE DISCHARGE & 2 TO 3 % OXYGEN CONTENT.
E 20028. 61, 5.2) AIR/OIL CONTROLLER FUEL OIL TEMP CONTROLLER AND MASTER PRESSURE CONTROLLER TO CHECK SERVICE AND SETTINGS TO ADJUST AS REQUIRED.
E 20028. 62, 5.3) FD FAN I.P. POSITIONER PNEAUMATIC ACTUATOR TO OVERHAUL & POSITIONER TO CONFIGURE AND INITILISED. F.D FAN LIMIT SWITCHES TO BE CALIBRATED.
E 20028. 63, 5.4) PLC BATTERIES TO CHECK AND RENEW AS REQUIRED.
E 20028. 64, 5.5) SATISFACTORY WORKING OF ABOVE SYSTEM IN AUTO & EMERGENCY MODES FOR BOTH AUX BOILERS TO BE SHOWN TO CEO/SUPDT.
E 25034 : CONTROL VALVES
FOLLOWING V/VS CONTROLLERS ACTUATORS POSITIONERS TO BE OVERHAULED CALIBRATED AND SATISFACTORY WORKING SHOWN TO CEO/SUPDT. SPARES IF ANY REQD. TO BE QUOTED. AA) TEMPERATURE CONTROL VALVES - MAKER KORVAL. E 20034. 10, 10) AUX BOILER F.O HEATER MODEL : KCR-DP PNEUMATIC DIAPHRAGM TYPE ACTUATOR MODEL NO : K03-R1 RANGE 0-150 DEG. BB) PRESSURE CONTROL V/VS - MAKER KORVAL
E 20034. 12, 12) EXCESS STEAM ( DUMP V/V )
E 25087 MISCELLANEOUS REPAIR JOBS
E25087.17, 15. AUX BOILER low low water level float gets punctured too often because of this low low water level trip doesn’t work . Same to be rectified using ships spare
SMEC AUTOMATION PRIVATE LIMITED (BID ID -869613)
AKSHAY CONTROLS AND SYSTEMS PRIVATE LIMITED (BID ID -869187)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .