Loading…
Loading…
Tender Value
₹11.4 L
EMD Value
₹28,485
Closing Date
26 Sept 2026, 2:00 pmDue tomorrow
AEE
O/o the AEE, KLC Subdivision
GENERAL Renovation of Office of Secretary to Chief Minister 4 th floor North block Govt Secretariate Renovation of Office of Secretary to Chief Minister 4 th floor North block Govt Secretariate General Civil Work
2026_PWD_871307_1
PWD/BLDG/TR/11825/2026_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
90 days
Govt.Secretariat, TVPM
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
₹28,485
19 Sept 2026
19 Sept 2026
28 Sept 2026
19 Sept 2026
26 Sept 2026
19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1WORK | |||||
| 1.001 | 15.39.2:Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking with in 50 metres lead:Thickness above 10mm upto 25 mm | 5.88 | sqm | - | - |
| 1.002 | 12.45.3:Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board | 31.8 | sqm | - | - |
| 1.003 | 12.52.1:Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending | 21 | sqm | - | - |
| 1.004 | OD86623/2026-2027:Plywood paneling (18 mm): Providing and fixing paneling using plywood, 18 mm thick
plywood ( BWP 710 Grade ) to be fixed onto the existing framework using drywall screws and
adhesive including primer. Complete as per the direction of the Engineer- in- Charge including
all costs of accessories, labour charges etc. complete | 92.54 | sqm | - | - |
| 1.005 | OD92700/2026-2027:Plywood paneling (12 mm): Providing and fixing paneling using plywood, 12 mm thick plywood ( BWP 710 Grade ) to be fixed onto the existing framework/wall using drywall screws and adhesive. Complete as per the direction of the Engineer- in- Charge including all costs of accessories, labour charges etc. complete | 69.72 | sqm | - | - |
| 1.006 | OD86624/2026-2027:Mica panelling : providing and fixing mica 1mm thick on to the existing plywood (superior quality) using adhesive complete as perthe direction engineer in charge including all the cost of accessories, labour charges etc. complete(data based on 9.126.1 of DAR) | 199.82 | sqm | - | - |
| 1.007 | OD86626/2026-2027:Providing and fixing charcol fluted wall panel on to the existing surface using adhesive
complete as per the direction of engineer in charge including all the cost of accessories , labour
charges etc complete. | 16.38 | sqm | - | - |
| 1.008 | 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):
For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) | 157.6 | kg | - | - |
| 1.009 | 9.82:Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | 2 | no | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
GST.pdf
Tender Documents • 0.14 MB
EMD.pdf
Tender Documents • 0.00 MB
Requisitionforepayment.pdf
Tender Documents • 0.15 MB
license.pdf
Tender Documents • 0.18 MB
integritypactcertificate.pdf
Tender Documents • 0.15 MB
preagreement.pdf
Tender Documents • 0.09 MB
viewsbd.pdf
Tender Documents • 2.98 MB
Affidavit.pdf
Tender Documents • 0.19 MB
Bidsubmissionletter.pdf
Tender Documents • 0.15 MB
nits.pdf
Tender Documents • 0.03 MB
BOQ_1476692.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .