| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.3 LAccepted-AOC | ₹36.3 L Quoted ₹37.4 L | 1 | Accepted-AOC AOC |
| 2 | 2₹39.8 L+₹2.4 L (6.49%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹39.8 L+₹2.4 L (6.49%) | 2 | Rejected-Finance nOT l-1 |
| 3 | 3₹39.9 L+₹2.5 L (6.77%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | ₹39.9 L+₹2.5 L (6.77%) | 3 | Rejected-Finance nOT l-1 |
| 4 | 4₹42.5 L+₹5.1 L (13.6%)Rejected-Finance | ₹42.5 L+₹5.1 L (13.6%) | 4 | Rejected-Finance nOT l-1 |
| 5 | 5₹42.7 L+₹5.3 L (14.2%)Rejected-Finance | ₹42.7 L+₹5.3 L (14.2%) | 5 | Rejected-Finance nOT l-1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
18 May 2022, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
REPAIR / REPLACEMENT OF LT DISTRIBUTION LINES AND UNSV LT UG CABLE, MCCB, AND OTHER CONNECTED ACCESSORIES UNDER AOR OF GE(A) BHUJ
2022_MES_515158_1
8898
Open Tender
Civil Works
Item Rate
330 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹96,000
Yes
8 Oct 2023
24 Mar 2022
19 May 2022
24 Mar 2022
18 May 2022
9 Apr 2022
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Disconnecting, taking out, removing old existing unserviceable LT underground cable of size 10 sqmm to 50 sqmm etc. complete all as specified and directed
Disconnecting, taking out, removing old existing unserviceable LT underground cable of size 70 sqmm to 120 sqmm etc. complete all as specified and directed of
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 2 core 10 sqmm
All as per item No 10 here in above but of size 4 core 16 Sqmm
All as per item No 10 here in above but of size 3.5 core 25 Sqmm
All as per item No 10 here in above but of size 3.5 core 35 Sqmm
All as per item No 10 here in above but of size 3.5 core 50 Sqmm
All as per item No 10 here in above but of size 3.5 core 70 Sqmm
All as per item No 10 here in above but of size 3.5 core 95 Sqmm
All as per item No 10 here in above but of size 3.5 core 120 Sqmm
S&F cable jointing kit for 1100 Volts (earthed) grade cable for outdoor straight through heat shrik type joint and taking out the old existing joint kit complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm cable.
S&F cable jointing kit for 1100 Volts (earthed) grade cable for outdoor straight through heat shrik type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm cable.
S&F cable jointing kit for 1100 Volts (earthed) grade cable for outdoor straight through heat shrik type joint and taking out the old existing joint kit complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm cable.
S & F for Aluminium Terminals suitable for XLPE UG cable of size 25 Sq mm and taking out the old existing lugs complete all as specified and directed
S & F for Aluminium Terminals suitable for XLPE UG cable of size 35 Sq mm and taking out the old existing lugs complete all as specified and directed
S & F for Aluminium Terminals suitable for XLPE UG cable of size 50 Sq mm and taking out the old existing lugs complete all as specified and directed
S & F for Aluminium Terminals suitable for XLPE UG cable of size 70 Sq mm and taking out the old existing lugs complete all as specified and directed
S & F for Aluminium Terminals suitable for XLPE UG cable of size 95 Sq mm complete all as specified and directed
S & F for Aluminium Terminals suitable for XLPE UG cable of size 120 Sq mm and taking out the old existing lugs complete all as specified and directed
M & L for stainless Steel Nut bolts with double washer suitable sizes and length for Fixing the Aluminium Terminals in the LT Pnael Box and taking out the old existing Nuts,bolts complete all as specified and directed
S & F for Digital panel mounted Voltmeter flush mounted case of suitable sizes fixed in the existing LT panel board with internal wiring connection and taking out the old existing VlotMeter complete all as specified and directed
S & F for Digital panel mounted Ammeter flush mounted case of suitable sizes fixed in the existing LT panel board with internal wiring connection and taking out the old existing Ammeter complete all as specified and directed
S & F for LED indicator lamps for phase indication for the existing LT panel board with internal wiring connection and taking out the old existing Indicator lamp complete all as specified and directed
M & L for repair of the existing broken LT panel door for proper welding and fixed with hinges,welding portion tobe painted and matching with the existing LT panel Colour complete all as specified
Supply and fix in repiars the following items and disconnecting,taking out the old unserviceable one, including necessary lugs of any size and capacity wherever reqd :-MCCB Thermal Magnetic release 4 pole 63 Amps 16 KA.
MCCB Thermal Magnetic release 4 pole 100 Amps 16 KA.
MCCB Thermal Magnetic release 4 pole 160 Amps 36 KA.
MCCB Thermal Magnetic release 4 pole 250 Amps 36 KA.
MCCB Thermal Magnetic release 4 pole 400 Amps 36 KA.
Changeover Switch ON load type 4 Pole 63 Amps in Sheet Metal Enclosure
Changeover Switch ON load type 4 Pole 100 Amps in Sheet Metal Enclosure
Changeover Switch ON load type 4 Pole 200 Amps in Sheet Metal Enclosure
Trimming / cutting of the tree branches / bushes which falls within a clear distance of 3 meter from all sides from the HT/ LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning area complete.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 6 Sqmm.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 10 Sqmm.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ NOTE - The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe
Dismantling of old deteriorated ACSR Conductor , of any size , any type and supply and fix aluminium conductor , steel reinforced (ACSR) , of any size, any type , as per existing one and stringing properly on the insulators and binding with aluminium wire , connectors , jumpers etc complete., Note :- Measurement and payment shall be made by measuring horizontal distance between centres of two adjacent poles and adding 3 % for sag , jointings, jumpers etc.
Unbinding of the ACSR conductor from the insulator on pole, restringing the conductors, tightening LT over head line, connector, jumper, screw nuts, bolts and binding to the insulators using required size aluminum binding wire complete all as directed.
Preparation of PCC/Steel tubular Poles not more than 8 mtr height from ground level for painting by cement based paint/aluminium paint incl surfaces of steel / MS cross arms, channels, clamps, street light brackets and GI protection pipes etc (any nos) which are fitted on LT single PCC pole, by scrapping and applying two coats of aluminium paint over a coat of red oxide primer and marking pole number on the same pole with yellow paint in black painted suitable back ground at a height of two metre above ground level & with 5 cm large bold letters also 2" wide colour strips painted with two coats of synthetic enamelled paint up to the height of 1.5 m from coping of pole all as specified and directed
S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts grade for LT lines fixed on poles complete all as specified and as directed.
S&F Shackle type 75mm height and 90mm dia insulator, porcelain, vitreous, white, brown or green including galvanised mild steel strap 31mm X 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure upto & including 1100 volts fixed on LT poles complete all as specified and directed.
Dismantling of old unserviceable stay assembly, and Supply and fix Stay assembly complete with all accessories as shown in electrical plate no. 1 of SSR Part - I ,1991, using stay rod 16 mm dla including stay wire. Note :- Excavation , earth work , foundation concrete ,loop insulator, stay clamps, for the new stay shall be measured and paid separately under respective item of schedule
Testing of lightning conductor earthing with the help of earth tester in presence of users rep presventative and recording the earth results in test register of each sub depot and MES register duly signed by OC of sub depot jointly signed by MES and users rap complete all as directed.
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 350 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 100 Amps 16 KA - 04 Nos (04 No for outgoing)
(g) MCCB 4 Pole 63 Amps 16 KA - 01 Nos (01 No for outgoing)
(h) MCB SPN 32 Amps 10 KA - 02 Nos (02 No for outgoing)
All as per item no 51 here in before but LT Panel consisting of following items
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 400 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 350 Amps 16 KA - 01 Nos (01 No for outgoing)
(g) MCCB 4 Pole 63 Amps 16 KA - 02 Nos (02 No for outgoing)
Dismantling of ACSR or AAC conductor form pole of any size, type and capacity complete all as specified and directed
Supply and fix in repairs Weather Proof PVC Junction Box made out of not less than 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers all as specified and directed
Supply, laying and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sqmm 2 core x 1.0 sqmm 1 core FR grade 1100 volts grade in PVC conduit pipe complete all as specified and directed.
Boring of holes under road, pavement hard standing by trenchless technology using ultra sounding technique and necessary machine incl HDPE pipe 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and installation of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) including all necessary earth work and PCC work, providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed
Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete including necessary earth work complete all as specified and directed
M/s Bombay Novelty Stores
anand enterprises
SHOBHIT BUILDERS
Sai Ram Electricals and Refrigeration Works
Abhishek Enterprises
Pelectricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .