Loading…
Loading…
Tender Value
₹3.4 Cr
EMD Value
₹3.5 L
Closing Date
8 Sept 2026, 6:00 pm
Superintending Engineer, P.H.Circle Bhuj.
Dismentaling, shifting, overhauling, servicing, repairing and suppling of required spares of VT pumps and complete ITC work of Existing VT Pump sets, electrical & mechanical equipments from GWIL Bhachau Station to Tappar Dam Jackwell No 2 with 24 month of maitenance and repairs work including existing pumping machinery Ta. Anjar Dist. Kutch
338862
06/2026-2027
Open
Miscellaneous Works
Works
Kutch
8 documents required · 8 mandatory
₹6,000
Executive Engineer, P.H. Works Division , GWSSB, Anjar - Kachchh
₹3.5 L
25 Aug 2026
25 Aug 2026
25 Aug 2026
8 Sept 2026
25 Aug 2026
Name of Work: Dismentaling, shifting, overhauling, servicing, repairing and suppling of required spares of VT pumps and complete ITC
work of Existing VT Pump sets, electrical & mechanical equipments from GWIL Bhachau Station to Tappar Dam Jackwell No 2 with
month of Comprehensive Operation , maitenance and repairs work including existing pumping machinery Ta. Anjar Dist. Kutch
Name of Head Work : Tappar Dam Jackwell 2 (Varshamedi JW)
Schedule-B-2:- Upgradation of Electro-Mech Components Tappar Jackwell 2 (Varshamedi JW)
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Supply, Delivery, Lowering, laying, Jointing & welding in position to correct line & level of
Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm)
M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/
ammendment for following thickness outside diameter at GWSSB store or site anywhere in
Gujarat State including all taxes, insurance, transportation, freight charges, octroi, inspection
1 charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete. 60 Mtr 3736
(Rate for MS Pipe based on the ex. works price of HR Coil as Rs.58500 per MT - withouth
GST (Above 3.15 mm to 10 mm) & Rs. 59000.00 per MT without GST (Above 10 mm) as
onJan-23.( WPI Index of H. R Coil of Dec-22 is 144) 355.6 mm OD 5.6 mm Thickness
M.S.Specials (Flanged Ends) up to and Above 300 mm Dia (20 kg/ flange), MS 40*40mm
girder of 12m Dia for Circular EOT, etc
Butterfly Valve - (PN - 1.6):
Supply, Installation, Testing & Commissioning (SITC) of ISI mark Cl D/F Butterfly Valves
as per IS: 13095 (Latest Edition) of following class and diameter including all taxes,
insurance, transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores. stocking etc. complete. as per IS and
Specification.Size: 350 mm NB for 3 SCF
Butterfly Valve - (PN - 1.6):
Supply, Installation, Testing & Commissioning (SITC) of ISI mark Cl D/F Butterfly Valves
as per IS: 13095 (Latest Edition) of following class and diameter including all taxes,
insurance, transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores. stocking etc. complete. as per IS and
Specification.Size: 800 mm NB
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Supply, installation, testing & commissioning of 350mm dia flange ends Expansion Bellow
of PN1.0 for delivery pipe as per EJMA standards of overall length of minimum 300 mm,
designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of
following MOC & pressure ratings. MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA
240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS 1538 / IS
6392 ) & Limit Rods & Nuts: CS - IS 1367. for scf pump x
Reflux Valves/DPCV:Providing and supplying ISI mark CI D/F Reflux Valves as per
IS:5312 (Latest Edition) of following class and diameter including all taxes, insurance,
6 transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to 3 No. 65376
departmental stores, stacking etc. complete Reflux valves PN 1.6 IS 5312 with ISI mark
Reflux Valves/DPCV:Providing and supplying ISI mark CI D/F Reflux Valves as per
IS:5312 (Latest Edition) of following class and diameter including all taxes, insurance,
7 transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to 2 No. 415568
departmental stores, stacking etc. complete Reflux valves PN 1.6 IS 5312 with ISI mark
Pressure & Vacuum Gauges with Accessories
Design, Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Gauge, ±1%
accuracy, Direct bottom 1/2"
NPT (M) process connection, IP 67, Glycerine filled, S
8 316 Movement material, Aluminium dial with black gradu 8 No 1412
S304 Case with Bayonet Type Bezel, SS316 L Bourdon Tu
ation on white background, Micro Zero adjustable pointer, neoprene
be, SS gasket, Blow out disc, shatter proof glass, SS tag plate etc as per IS 3624. 150 mm
Dial Size & 0 to 20 Kg/cm2
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Civil work : Supply at Site, Installation, Testing & Commissioning of lying reinforced
cement concrete in foundation,thrust block/piping supports etc. with black trap crush metal
as coarse aggregate for raft,grillage footing with necessary centring frame work consolidating
as per directive in 1:2:4 ratio.
Exisiting Pump Set Repiring:-Rewinding of Motor, Bearing, Mechanical Seal, O ring, Oil,
Replacement of impeller, Replacement of Rotor Shaft,Replacement of NDE Housing,
Replacement of Oil Chamber, Dual PVC Sheathed Round Type Copper Flexible Cablle with
10 Gland Sealing (3R x 4C x35 sqmm)+(3R x 4C x35 sqmm)+(1R x 7C x1.5 sqmm) 25 Mtr and 2 Job 1158863
Overhauling Charges(Dismentaling of pump assembly ,dynamically balancing of rotor &
impeller ,Complete assembly of pump motor set,Hydraulic Testing etc.
Existing Pump 52m,1400m3/h and 300KW
BUSBAR CHAMBERS:
Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S.
sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar
supports with Aluminium busbar having current density not more than 0.8 Amp. / sq.mm
11 (Rated current / cross section area) duly wrapped with colour insulation tape for phase 3 NOS 8544
sequence, three phase & neutral each Suitable for following current capacity with necessary
painting mounted on wall or pedestal frame of required size with necessary connections.
(i) Suitable for 600 Amp. capacity (2 Incoming and 6 outgoing)
12 (ii) Suitable for 600 Amp. capacity (2 Incoming and 2 outgoing) 3 NOS 8544
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
HV VCB SWITCHGEAR PANEL:
Supply, installation, testing & commissioning both side extensible, Indoor type HV
Switchgear panel confirming to IS-3427, IS-2516 (Part I & II.sec.1 ) & IEC-60056 & IEC-
62271-100/200 for use on 3phase, 50 Hz, unearthed AC supply system and having breaking/
ruptuing capacity of 500 MVA (26.3 kA for 3sec) complete with spring charged mechanism,
ON-OFF mechanical push button, operation counters, Breaker TNC switch, Breaker L/R
switch, necessary auxiliary switches, closing coil, shunt trip, protection relays & Indicators
etc., complete.
The panel shall comprise of air insulated busbars provided with heat shrinkable PVC sleeves.
The VCB trolley shall comprise of three
vacuum interrupters with epoxy support insulators and self aligning finger type isolating
contacts and necessary mechanical interlocks,
safety shutters, isolating plugs. Enclosure shall be openable from front as well as rear end.
The breaker shall be Manual cum motorised mechanism with following accessories.
a) 96 x 96 mm square flush mounting type Ammeter & Volt meter with selector switches
b) Multi function meter
c) Double core, cast resin type current transofrmer having ratio as per requirement, one core
for metering & one core for protection
13 having required class of accuracy. 1 Set 990802
d) Instantaneous under voltage relay & Temperature rise tripping Relay,
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
e) Triple pole IDMTL two over current and one earth fault relay with current setting range 50-
f) Electrical closing. coil & shunt trip coil operating on 110 V DC.
g) Auxiliary relay for anti pumping device.
h) Three limb, drawout type, feeder connected, cast resin insulated, three phase Potential
transformer having ratio & burden as per
reqirement & Class 0.5 accuracy.
i) Annunciator Windows, Common Hooter / Alarm bell operating on 230 AC/ 110 V DC.
j) Cable boxes suitable to terminate 3 core XLPE cable of required size (As per design).
k) 230V AC to 110 V DC power pack for closing & tripping circuit common.
l) Breaker ON-OFF, Auto trip and spring charged indicators.
m) Phase indicating & panel illumination lamps with plug socket.
n) Space Heater with Thermostat.
11 kV HV Switchgear Panel- Comprising of 630 A Vacuum circuit breaker for 1 no.
Incomer, 2no. O / G feeders for 11/0.433 kV distribution transformers
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
CHEMICAL EARTHING SYSTEM: Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by
highly conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved make OEM has to submit
test certificate including value of earth resistance of installation duly stamped and signed by
14 agency and officer Incharge has to ensure the value of earthing resistane mentioned in test 6 Nos 4546
Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound
should be capable to retain moisture for long time Necessary test report must be submitted
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg. ( 4 tc body + 2 lvdb)
(c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing,
A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing
15 in normal soil. 6 Nos 8551
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg. (4 for TC and 2 for VCB)
Supply and erection of required size HOT Deep Galvanised Iron Strip for earthing of LT
Panel board, Motors, etc., using proper clamp.
Supply and erection of required size Copper Strip for earthing of HT/VCB/Transformer/LT
Panel board, Motors, etc., using copper clamp.
PVC insulated flat submersible Copper cable as per detailed technical specifications of R/C
18 ofGWSSB conforming to IS 694, IEC 60227 / 60228.1 R x 3 C x 35.0 mm2 (25 Mtr 6run 300 Mtr 652
for each SCF pump)
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Replacing the breather of the Transformer of following capacity. 500 & 1250 KVA
Routine maintenance of Transformer inoperating covering Insulation Resistance oil
20 breakdown strength, reconditioning/replacement of silica gel, cleaning of transformer & 4 Job 2543
topping up to of oil if required.(Oil will be provided departmentally or at extra cost.)
Cable Terminals (Lugs) Providing & fitting crimping type Cable Terminals (Lugs)
21 conforming to IS of following types and sizes;Copper Tubular Terminals (Long Barrel) (in 20 Each 122
120 Sq. mm.) 6 for each pump
Replacing the oil level glass of the 250/315/500/750/1000/ 1250 KVA by new one
23 Outside painting of Transformer for the following capacity 500 KVA 2 Job 1568
24 Outside painting of Transformer for the following capacity 1250 KVA 2 Job 1696
Transformer oil having good resistance to high electrical stress, high di-electrical strength
25 (50KV) low viscosity, low pour point, high flash point and excellent thermal properties for 600 Ltr 90
efficient heat transfer and cooling as per IS 335-1972 (For JW 1 & 2)
Filtration of transformer oil as per I.S. for removal of moisture, carbon, slurry etc.by means
of circulating oil through vacuum pump from heating elements and filters to with stand the
breaking strength of the oil above 40KV beyond one minute tested in oil testing Kit(A) On
site (For JW 1 & 2)
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
LV MCC Panel with Micro processor based soft starter
SITC of LV MCC Panel totally enclosed, dust & bermin proof, indoor type, minimum degree
of protection - IP 52 as per IS: 2147, operation
on 3-Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with instrumentation
compartments accomodating LED type indicating
lamps, control contactors as per IS: 13947, CT of accuracy class- I as per IS: 2705, relays,
meters & control MCBs, air insulated
electrolitic grade Aluminum bus bar for three phase & neutral system with incomming
breaker- microprocessor based Air Circuit
Breakers (electrically operated drawout type)/ air break fixed type MCCB with trip free
mechanism, current limiting type as per IS:
Motor Contractor (as per type -2 coordination), Overload Relay with built-in single phasing
prevention feature & auxiliary feeders as per
SLD drawings, momentary contact type push buttons, equipment fittings, bus bars, cable
27 boxes, cable gland, incoming & ougoing cable 1 NO 1233045
connection for 1100V grade, Aluminium/ Copper conductor XLPE / PVC insulated & PVC
sheathed armoured cable, 10% spare terminals,
power wiring using 1100V grade, FRLS insulated copper conductor wires conforming to IS:
694 & 8130, cable compartments / alleys of
minimum 300 mm size, GI / Al earth bus bar for entire length.
MCC shall be fabricated from cold rolled, coled annealed (CRCA) sheet
steel & minimum thickness of various members shall be as follows:
Base Frame / Channel / Gland Plate: 3 mm, Load Bearing Members / Doors: 2 mm and
Internal Partitions: 1.6 mm.Microprocessor based Soft Starter with built-in by pass
contactor,Semiconductor Fuses, Harmonic Filters, cast resin type CT, Digital
MFM, Analogue Ammeter & minimum 10 Channel Temperature Scanner with RS
communication port.
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Supply, installaton, testing & commissioning LV APFC panel consisting of required
capacitor banks for continuous duty to improve P.F.
0.85 to 0.99 in required steps enclosed in dust & vermin proof compartment, indoor type,
fabricated from CRCA sheet steel with
minimum thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load bearing
members / doors & 1.6 mm for internal
partitions, minimum degree of protection - IP 42, busbar chamber, required size of Al bus bar
/ terminals, minimum 10 stage APFC relay,
metering, indicating lamps, push buttons complete as per IS: 16636-2017 with latest
ammendment & detailed technical specification and
data sheet as under.
28 Above 200 & up to 300 KVAR: APFC panel consisting following items. 1 No 442717
a) 630 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-
630 A range analogue ammeter of 96 x 96 mm size
with selector switch
c) 3nos. 630/5A, 10 VA CL-1.0 cast resin type current transformer
d) Suitable rating of MCCB/ MCB & Contractor for each capacitor bank
e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB/ non toxic
oil, internally delta connected with built in internal
fuses complete with discharge resistances & terminal cover) of approved make in required
steps (e.g., 300 KVAR capacity will be provided in
steps of 2nos x 5 KVAR, 2 nos x 10 KVAR, 2 nos x 15KVAR, 2 nos x 20 KVAR, & 4 nos x
50 KVAR) f) Enclosure dimensions- 1900 (H) x 1200 (W) x 600 (D)
Point wiring for Light / Fan/ Bell/ Primary Point with2-1.5 sq. mm & earth wire of 1.5 sq.
mm (green)both are of ISI marked 1.1 kv grade FRLS PVCinsulated multi strand copper
wires upto maxlength of 10 mt, in below type of pipe erected with6A TissinoType ISI
29 marked flush type switch / bellpush and accessories erected on Metal /PVC/Wooden Box 10 Pt 351
covered with 3 mm thickPC(Polycarbonate) /Acrylic/Laminated sheet. withnecessary Lamp
holder/ceiling rose /H.D.Connector as directed.(a) with medium class Rigid PVC pipe
andaccessories erected flushed on wall/ceiling complete
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Point wiring for independent PLUG with followingsize mains earth wire of 1.5 sq.mm
(green) bothare of ISI marked 1.1 KV grade FRLS PVCinsulated multi strand copper wires
upto 10 mtlength, in following below of pipe erected completewith ISI marked 3 / 5 Pin
socket and tissino typeswitch erected with earth continuity connectionerected on Metal /
30 PVC/Wooden box covered with3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. [B] 4 Pt 489
6/16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Mains from mcb d b boards.(a)
with medium class Rigid PVC pipe andaccessories erected flushed on wall/ceiling complete
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Supplying & erecting single phase approvedmake industrial exhaust fan suitable formedium
31 duty ring mounted low noise operationsuitable for medium duty having following diasize and 3 No 2034
maximum speed in RPM 305 mm dia 900 RPM Cat II
Supplying and erecting LED street light / Floodlight fittings with High power White LEDs
wattage of 3 Watt and above assembled onsingle MCPCB, efficiency more than 130 lm/wand
corrosion free High pressure die castaluminum housing with smooth finish powdercoated and
heat sink extruded aluminium withdiffuser and Polycarbonate optics/ lenses, withtoughened
glass with company mark/nameengraved or embossed 160 to 270 V,PowerFactor more than
0.95, THD < 10 %, CCT3000 K to 5700K,Uniformity ratio >0.45,Luminaire efficacy>
32 lumens/watt . LEDdriver efficiency > 85 %.( fittings required LM-79 & LM-80 6 No 6501
certificates)(NOTE: Belowdescription have shown ranges of Wattagecapacity of LED
fittings.The Engineer inchargemay select any wattage capacity between theranges
shown.)(A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC linesupply with over-voltage protection. (iv) above
90 to 120 watts
Supplying & erecting Galvanized M.S pipepost “B” class 88.9 mm O.D 4 mtr. Long duly
33 painted with two coats of aluminium paintcomplete with metallic base plate of 300 mm x300 6 No 3194
mm x 4mm thick for using as a compoundlight pole with approx. weight 32 Kg.
Supplying & erecting XLPE(IS:7098)(I)-88 ISIunarmoured copper cable 1.1 KV grade to
beerected as directed of following size.(A) 2 core 2.5 Sq. mm
Providing Suppling Lifting chain (12mm) with O ring at every 1 meter having a set of 25 Mtr
Portable cabin (15ftX12ftX10ft) One sided Shutter with 2.0 Ton Vestar Make Air
Conditioner with 01 main door,03 Tubelights, 03 Fan, 03 Window with grill,18mm cement
36 sheet,07mm MDF sheet, 1mm carpet 1mm GI Sheet, 50mm Glasswool, Square pipe,Epoxy 2 Nos 304000
primers applied inside and outside epoxy colour,4Nos. hook, 06 legs(1 Nos For VCB &
Nos. for Existing PMCC Panel Jackwell -2)
Supplying & Fixing SMC Chequered platehaving 12 mm thickness, made out of SMC
Confirming to IS 13410 & by Hot pressCompression Moulding technique Suitable cut &
37 50 SQmtr 5840
fixed with MS Angle Frame to Fit TrenchWidths as per site requirement approved .by
engineer incharge 3 x 4 slot
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
Carryout routine maintenance and servicing of L.T. cubical panel board having
approximately15 to 22 Nos. of switches cleaning andservicing the contacts with CRC,
tighting theconnections of incoming and outgoing cables.and hacking the operating
mechanism forsmooth functioning of switches. and puttingthem in smooth working
order.(2Nos. Control panel and 2Nos APFC for SCF pump panel and 1Nos. Control panel &
1 Nos. APFC for Old JW VT pump panel)
Providing and fixing 1.20 M high fencing with 2.0 M long M.S. Angle posts 40 MM X
MM X 6 MM and oil painting 3-coats fixed at 2.5 M C/C with five Horizontal lines and two
39 diagonals of galvanized steal barbed wire weighing 9.38 Kg per 100 M staples including 150 mtr 388.05
fixing the posts in ground with 0.5 M X 0.5 M X 0.5 M block in cement concrete 1:5:10 etc
complete, and gravel bed in switch yard.with gate( For JW1 & 2)
Providing and laying best quality gravel inside the wire fencing compound as per
requirement for (For Switch Yard and TR Yard) - Minimum 20mm Layer Thickness
Supplying of screened cleaned pea (rounded) gravel of
following sizes)(i) 12mm nominal size.( For JW1 & 2)
Ultrasonic Type Level Transmitter with Integral Display :
Design, Supply, Installation, Testing and Commissioning of NOn Contact Ultrasonic Type
Level Transmitter with IntegralDisplay.Sensor with Head Mounted Transmitter:The sensor
should be non contact type, field mounting type, housing shall have minimum IP65
41 protection, PP/ PVC SensorMOC, Microprocessor based indicator with LED / LCD digital 1 No 59723
display,panel/ wall mounting type, power supply shall be 110-
240 Vac or 15 to 36 Vdc, 50 Hz ± 10 %.Accesories: Mounting bracket, nut, bolts etc as per
system requirement and Hook up diagram of the Instruments.Level Transmitter shall be
suitable for following Range. 0-15 Mtr
Providing & fitting heat shrink cable termination / jointing kits for 1.1kV grade PVC/ XLPE
insulated cable including necessary earth
connectivity connection, material & consummables making the termination/ joint complete
ensuring the joint resistance is within the
permissble limit as per IS, of following types & sizes: Indoor / Outdoor End Termination Kit
Cable Size 185-300
Supplying Rubber Matting of 4.00 mm thickness as per IS 5424 and of require length and
breadth with good insulation property for 22kv
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
LOW VOLTAGE (LT) CABLES
Supply and unloading & delivery at site, storage & security at site of 1.1 kV, A2XFY/2XWY
XLPE insulated (IS 7098) / PVC insulated (IS 1554) AL / Cu conductor cables as per
44 specification & IS. The cable when laid outside the building shall be laid underground in 180 Mtr 954
excavated trench, as per specified method and shall be laid in prepared trench on cable tray
when laid inside the building.
3.5C x 300 sq. mm. A2XFY Cable
Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper
conductor, galvanised steel flat strip / round
wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall
surface with necessary clamps / in existing cable
45 trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) 1000 Mtr 815
conforming to IS: 7098 (Part-1) & IEC:
60502 (Part-1) of following sizes:
11 kV (Earthed / Unearthed) Grade Cable- Aluminium Conductor: Supply, laying, testing &
commissioning 11 / 11 kV (UE) grade, XLPE insulated, stranded Aluminium conductor,
galvanised steel flat strip
/ round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on
46 wall surface with necessary clamps / in existing 180 Sq.mtr. 1261
cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site
requirement) conforming to IS: 7098 (Part-2) & IEC:
60502(Part-2), of following sizes: 3 Core x 240 Sqmm
Cable Terminations / Jointing Kits for Cable Terminations / Jointing Kits for 11 kV (UE)
grade XLPE Cable: Providing & fitting heat shrink cable termination / jointing kits for
kV (UE) / 11 kV (E) grade XLPE insulated cable including necessary earth connectivity
connection, material & consummables making the termination/ joint complete ensuring the 5 Each 6985
47 joint resistance is within the permissble limit as per IS, of following types & sizes:
i) indoor Terminations Kit suitable for 240 to 300mm & 3C
ii) Outdoor Terminations Kit suitable for 240 to 400mm & 3C 1 Each 11487
m Description Qty. Unit Rate (Rs.) Amount (Rs.)
CABLE END TERMINATION AND CONNECTION:
SITC of Double compression Weather proof type Ni-Plated brass cable glands and crimping
type Bimetalic lugs / sockets with necessary tools and equipments as specified in
specifications and IS.
The glands and lugs / sockets shall be suitable for cable size and type mentioned below & as
per specificaitons.
1) Earthing the glands and armouring with earthing clamp and jumper and also connecting to
common earth bar. 20 Nos. 1009
48 2) The job also includes, if necessary, supply & fixing of extension busbar of same material
on MCCB or panel board terminal / connector to connect more than one no. of parallel cables
or to connect higher size cable to lower size unit. The job also includes earthing the glands
and armour of the cable with common earth bar or flexible copper mesh.(Cable termination
qty. shall be as per site requirement)
3.5C x 300 sq. mm. A2XFY Cable ( Runs for Tr. 1 & 2 to PMCC Panel)
3.5C x 240 sq. mm. A2XFY Cable (2 Runs for each APFC Panel)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01. VOL 1A Technical Bid Tappar.pdf
02. VOL 1B GCC.pdf
03. VOL 2 A Extent of work.pdf
04. VOL 2 B Tech Spec Civil.pdf
05. VOL 2 C Tech Spec Mech.pdf
06. VOL 2 D Tech Spec Electrical.pdf
07. VOL 2 E Tech Spec ITC and Dismentaling.pdf
08. VOL 3 Price bid with price.pdf
09. VOL 4 O and M Volume.pdf
10. Insurance Dt 19 03 12 GR.pdf
11. Minimum Wages.pdf
12. Letter for nCode Mobile App.pdf
13. ALL GR COMBINE.pdf
14. Ann shramyogi GR.pdf
15. Breakup of Schedule B2.pdf
16. Breakup of Schedule B1.pdf
17. Vendor list Civil as on Dt.03.08.2026.pdf
18. Vendor list Mechanical as on Dt.03.08.2026.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].