Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.3 CrAccepted-AOC 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | ₹6.3 Cr | 1 | Accepted-AOC L1 |
| 2 | Rejected-Technical B71 AKSHAY MITTAL INDUSTRIAL CO OPERATIVE SOCIETY BUILDING NO 5 ANDHERI KURLA ROAD MAROL MAROL ANDHERI EAST MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | - | - | Rejected-Technical Technically Not Acceptable |
| 3 | Rejected-Technical 41 1294 A6 SECOND FLOOR BEEVI COMPLEX C P UMMER ROAD KOCHI ERNAKULAM KERALA 682035 UDYAM KL 02 0026628 32AAECD3143Q1ZL R M | ERNAKULAM | KERALA | 682035 | - | - | Rejected-Technical Technically Not Acceptable |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not Acceptable |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Not Acceptable |
Tender Value
Refer Docs
Closing Date
6 Jan 2025, 3:00 pmClosed
DGM(SRM)
Ship Repair Materials Department Cochin Shipyard LTD Perumanoor PO
DIESEL GENERATOR CONTROLS JOBS IN NAVY VESSEL (RM.0807)
2024_CSL_220878_1
CSL/SR1/VKD430
Open Tender
Marine Services
Works
60 days
Karwar/CSl/Cochinport
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
16 Feb 2025
23 Dec 2024
7 Jan 2025
23 Dec 2024
6 Jan 2025
23 Dec 2024
23 Dec 2024 - 6 Jan 2025
Amount
DG AIR INLET (SERVICE COST)
1.8.18 Repairs to DG Air inlet restriction and exhaust back pressure with replacement of sensors for DGs Renewal of pressure sensors (04). Digital display to be provided. Renewal of DG expansion tank level sensor alongwith high & low level indication (12)
DG ROUTINES (SERVICE COST)
3.6.1 Replace the following 3.6.1.1 Thermo-couple 3.6.1.2 Electrical temperature indicator. 3.6.1.3 Tacho-meter transmitter. 3.6.1.4 Ball and roller bearing of pump motor.
DG ROUTINES (SERVICE COST)
3.6.5 Calibration and Repair/ Refurbishment of defective DG sensors 3.6.5.1 PSZ201 Very low inlet Lub-oil Pressure M/s Amote 3.6.5.2 TSZ201 Lub-oil Temperature M/s Amote 3.6.5.3 PSZ311 Low Safety Pressure M/s Amote 3.6.5.4 TSZ402 HT Water Temp, Engine Outlet M/s Amote 3.6.5.5. PSZ101 Low Lub-oil Pressure M/s Amote 3.6.5.6 PT401 HT Water Pressure, Engine Inlet M/s Den Force 3.6.5.7 Overspeed Sensor M/s Amote 3.6.5.8. PT50 Winding Temp Sensor M/s Amote
DG ROUTINES (SERVICE COST)
3.6.6 Calibration and Repair/ Refurbishment of defective DG harness 3.6.6.1 3-Way valve - 30 mtrs (3X1.5 sq mm) 3.6.6.2. Propotional valve - 30 mtrs (3X1.5 sq mm) 3.6.6.3 Lub Oil flow meter - 30 mtrs (3X1.5 sq mm) 3.6.6.4. Buffer tank level sensor - 30 mtrs (3X1.5 sq mm) 3.6.6.5. 3Way Solenoid Valve - 30 mtrs (2X1.5 sq mm) 3.6.6.6. MPD - 30 mtrs (3X1.5 sq mm) 3.6.6.7. Filter - 30 mtrs (3X1.5 sq mm) 3.6.6.8. RTD PT 50 (winding temp) - 30 mtrs (3X1.5 sq mm) 3.6.6.9. RTD PT 50 (bearing temp) - 30 mtrs (3X1.5 sq mm)
DG CONTROL PANEL (SERVICE COST)
3.194.1 Check setting value of voltage and phase order of LCP voltage relays (KV741 and KV742) as per Maintenance manual 02961928 para 8.4.1 3.194.2 Make calibration of all transducer and meters of LCP, RCP, and CCP 3.194.3 Carry out repair/calibration of defective sensors/gauges at shop floor. (SS to land the sensosr/gauges. 3.194.4 Serviceability checks of UPS batteries. 3.194.5. Replace PLC fans of LCP 3.194.6 Change Hour counters of LCPs 3.194.7 Clean PLC fans for any dust, sand, and impurities. 3.194.8 Test the grounding(bonding straps) continuity replace if necessary 3.194.9 Check all fuses and relays, replace if necessary. 3.194.10 Check the operation of wire break supervision module (SIMOS WBM-21) as per maintenance manual 02961928 para 8.5.1 3.194.11.Check all shutdown/protection relays for:- 3.194.12. check soldered connections in LCP. 3.194.13. Simulate the shutdown for each relay. 3.194.14. check is to be carried as per OI/maintenance manual of system 3.194.15 Check insulation resistance of LCP, RCP, and CCP for 24 V DC/380V AC as per Maintenance manual 02961928 para 8.3 to 8.3.2 with safety precaution para 5.1 to 5.3
DG AIR INLET (MATERIAL COST)
1.8.18 Repairs to DG Air inlet restriction and exhaust back pressure with replacement of sensors for DGs Renewal of pressure sensors (04). Digital display to be provided. Renewal of DG expansion tank level sensor alongwith high & low level indication (12)
DG ROUTINES (MATERIAL COST )
3.6.1 Replace the following 3.6.1.1 Thermo-couple 3.6.1.2 Electrical temperature indicator. 3.6.1.3 Tacho-meter transmitter. 3.6.1.4 Ball and roller bearing of pump motor.
DG ROUTINES (MATERIAL COST )
3.6.5 Calibration and Repair/ Refurbishment of defective DG sensors 3.6.5.1 PSZ201 Very low inlet Lub-oil Pressure M/s Amote 3.6.5.2 TSZ201 Lub-oil Temperature M/s Amote 3.6.5.3 PSZ311 Low Safety Pressure M/s Amote 3.6.5.4 TSZ402 HT Water Temp, Engine Outlet M/s Amote 3.6.5.5. PSZ101 Low Lub-oil Pressure M/s Amote 3.6.5.6 PT401 HT Water Pressure, Engine Inlet M/s Den Force 3.6.5.7 Overspeed Sensor M/s Amote 3.6.5.8. PT50 Winding Temp Sensor M/s Amote
DG ROUTINES (MATERIAL COST )
3.6.6 Calibration and Repair/ Refurbishment of defective DG harness 3.6.6.1 3-Way valve - 30 mtrs (3X1.5 sq mm) 3.6.6.2. Propotional valve - 30 mtrs (3X1.5 sq mm) 3.6.6.3 Lub Oil flow meter - 30 mtrs (3X1.5 sq mm) 3.6.6.4. Buffer tank level sensor - 30 mtrs (3X1.5 sq mm) 3.6.6.5. 3Way Solenoid Valve - 30 mtrs (2X1.5 sq mm) 3.6.6.6. MPD - 30 mtrs (3X1.5 sq mm) 3.6.6.7. Filter - 30 mtrs (3X1.5 sq mm) 3.6.6.8. RTD PT 50 (winding temp) - 30 mtrs (3X1.5 sq mm) 3.6.6.9. RTD PT 50 (bearing temp) - 30 mtrs (3X1.5 sq mm)
DG CONTROL PANEL (MATERIAL COST)
3.194.1 Check setting value of voltage and phase order of LCP voltage relays (KV741 and KV742) as per Maintenance manual 02961928 para 8.4.1 3.194.2 Make calibration of all transducer and meters of LCP, RCP, and CCP 3.194.3 Carry out repair/calibration of defective sensors/gauges at shop floor. (SS to land the sensosr/gauges. 3.194.4 Serviceability checks of UPS batteries. 3.194.5. Replace PLC fans of LCP 3.194.6 Change Hour counters of LCPs 3.194.7 Clean PLC fans for any dust, sand, and impurities. 3.194.8 Test the grounding(bonding straps) continuity replace if necessary 3.194.9 Check all fuses and relays, replace if necessary. 3.194.10 Check the operation of wire break supervision module (SIMOS WBM-21) as per maintenance manual 02961928 para 8.5.1 3.194.11.Check all shutdown/protection relays for:- 3.194.12. check soldered connections in LCP. 3.194.13. Simulate the shutdown for each relay. 3.194.14. check is to be carried as per OI/maintenance manual of system 3.194.15 Check insulation resistance of LCP, RCP, and CCP for 24 V DC/380V AC as per Maintenance manual 02961928 para 8.3 to 8.3.2 with safety precaution para 5.1 to 5.3
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .