Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.2 LAccepted-AOC | ₹23.2 L Quoted ₹24.4 L | 1 | Accepted-AOC AWARDED |
| 2 | 2₹26.3 L+₹1.8 L (7.45%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹26.3 L+₹1.8 L (7.45%) | 2 | Rejected-Finance nOT l-1 |
| 3 | 3₹27.5 L+₹3.0 L (12.4%)Rejected-Finance | ₹27.5 L+₹3.0 L (12.4%) | 3 | Rejected-Finance NOT l-1 |
| 4 | 4₹29.9 L+₹5.5 L (22.5%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹29.9 L+₹5.5 L (22.5%) | 4 | Rejected-Finance nOT l-1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 May 2022, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
REPAIR / REPLACEMENT OF AC, WATER COOLERS, REFRIGERATORS, STORAGE WATER HEATERS, CEILING FAN, EXHAUST FAN, DESERT COOLERS, SOLAR WATER HEATER ETC UNDER AOR OF GE(A) BHUJ
2022_MES_516384_1
8908
Open Tender
Civil Works - Others
Item Rate
270 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹60,000
Yes
30 May 2022
4 Apr 2022
4 May 2022
4 Apr 2022
3 May 2022
21 Apr 2022
Amount
Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecnting, dismantling and taking out the non functional Air Conditioner Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas (R-22) & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed. Make, Kirloskar,Tecumsha, Whrilpool
All as per Item No. 3 here in above but for Window AC 2 TR Capacity
All as per Item No. 3 here in above but for Split 2 TR Capacity
All as per Item No. 3 here in above but for Split 1.5 TR capacity
S&F Flame proof compressor sealed unit suitable for 2 TR Capacity for Flame proof AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed. Make, Shriram,Tecumsha, Whrilpool
S&F in replacement of Sealed unit compressor for 40/80 ltrs capacity water cooler including vacuum testing and filling of refrigerant gas to required pressure.
M&L in replacement Sealed unit compressor for 165 ltrs capacity including vacuum testing and filling of refrigerant Gas to required pressure
All as per Item No. 10 here in above but for 220 to 320 ltr capacity
All as per Item No. 10 here in above but for 330 to 490 ltr capacity
M&L for replacment of old unsv starting relay box carefully from window/Split type A/C 1 to 2 TR capacity of any make including making necessary elect connections,
All as per Item No. 12 here in above but for water coolers 40 to 150 Ltr capacity
All as per Item No. 12 here in above but for Refrigerator and deep Freezer any make & type
S&F in replacement over load protector suitable for 1.5 AC/WC 40/80 Ltr capacity
All as per item no 15 here in above but for 2.0 Ton AC / 120ltr WC capacity
All as per Item No. 15 here in above but for Refrigerator and Deepfreezer for any size of capacity
S&F Thermostat suitable for A/C, Water coolers, Refrigerators, Make- Kelton/Infass/Renutrol
S & Fix repair Starting capacitor 240 V, of the following size complete all as specified and as directed for 80 to 100 MFD
S & Fix repair Starting capacitor 240 V of the following size complete all as specified and as directed for 100 to 150MFD
S & Fix repair of Running capacitor 240 Volts of following size for 4/6 MFD
S & Fix repair of Running capacitor 240 Volts of following size for 30/36 MFD
S & Fix repair of Running capacitor 240 Volts of following size for 45/50/60 MFD
M&L for charging of refrigerant gas R-22/R-410A complete unit or to make up required pressure in existing air conditioner, window type invertor split AC/hot & cold split AC of any description any capacity any make and in any position complete all as specified and directed complete all as specified and directed.
M&L for charging of refrigerant gas 134A/600A to make up the required pressure in any type refrigerator complete all as specified and as directed.
Disconnecnting and taking out existing defective AC electric motor of any description & in any position of size 1/7 HP to 1/5 HP 230 Volts, strip opening for rewinding and removing to & from workshop for rewinding as apporved by Engr-in-Charge, rewiding with appropriate size copper supper enameled wire as approved incl insulating material such as illuminous paper, leatherized paper , cotton tape, glass sleeving, insulating varnish etc, testing at workshop to the entire satisfaction of Engr-in-Charge, transpotation & fixing the motor at site incl necessary connecting & testing complete all as specified and directed.
S& F in replacement fan motor AC 230 V high speed suitable for split AC 1.5/2 ton for any Make of AC all as specified and directed.
Supply and fix in repair copper made Condenser/Evaporator coil assembly complete suitable for 1.5/2.0 Ton window type/Split type AC unit complete including necessary brazing, welding, pressure and testing etc, replacement of worn out misc items required at site complete all as specified and as directed.
Supply and fix in repair copper made Condenser coil assembly complete suitable for all type Refrigerator complete including necessary brazing, welding, pressure and testing etc, replacement of worn out misc items required at site complete all as specified and as directed.
S&F in replacement Swing motor for indoor unit of Split type AC 1.5/2 Ton capacity all as specified and directed.
S&F in replacement of PCB of electronic circuit complete including display panel, signal receiving slot, display PCB (ie Remote) all as per existing one and suitable for 1.5/2 Ton Window type A/C : Make Blue Star, Videocon, LG, Samsung
All as per item No 31 but for 1.5/2 Ton Split Type A/C Ltr capacity
All as per item No 31 but for Refrigerator any make & type.
M & L for repair of defective electronic components in PCB circuit plate of Window/split type AC /Refrigerator of any model as directed.
Supply and fix in replacement of remote controller unit of Air Conditioner Split Type/Window type of any description any make and in any position 1.5/2 TR capacity
S&F in repair of blower motor suitable for 230 volts three speed of Blower motor three speed 1/7HP to 1/5 HP 900 rpm suitable for 230 volts of 1.5/2 TR AC.
Supply and fix in replacement blower motor 1/10 HP, 1350 RPM suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one.
S&F in replacement of drain pipe for water Cooler & Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed
M&L for testing of complete existing Window type/Split type AC unit of any description, any make & in any position by vacuum and pressure testing with Nitorgen (N2) and brazing the leakage/damaged copper pipe as required at site and charging of the refrigerant gas to required pressure and testing on completion complete all as directed by Engr-in-Charge. Make:- as per existing make of unit.
Dismantling and taking out exiting defective Copper tubing off Size of any description & in any position and supplying and fixing new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including Brass nut of any size as required and incl insulating material etc and testing complete all as Specified and directed.
Supply and fixing fan blade of any type and any description suitable for motor of any capacity for AC/water cooler/Refrigerator complete all as specified and directed.
S&F of workshop cable for lead wire pvc seathed 3 core size 40/0.0076 of multistranded copper conductors for water coolers/ AC, Make Plaza/Havells/Finolex
S&F of workshop cable for lead wire pvc seathed 3 core size 23/0.0076 of multistranded copper conductors for Desert coolers/ refrigerators, Make Plaza/Havells/Finolex
Taking out existing damaged/unserviceable copper tube insulation of any description & in any position and supply and fixing new insulation for copper tube of any size complete all as directed .
M&L for Replacement of existing unserviceable / damaged portion of the body of the water coolers i.e. in bottom / top / frame etc. with and including using new, 18 SWG, MS black sheet, cut to size, made to shape and size including necessary mouldings etc and fixing and riveting /bolting with existing parts / portion of the water cooler complete all as specified and directed.
Disconnecting dismanlting and taking out the functional Air Conditioner window type of any description any make and in any position 1.5/2 TR capacity Single Phase 50 HZ and reassembling fixing and testing the dismantled AC in new position complete all as specified and directed Note:- (i) The rate for above items are deemed to include for transportation to any distance inside the Army Area as appoved by Engr-in-Charge (ii) Charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A'
Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase 50 HZ and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing's etc with new one brazing of copper pipe & provn of pvc drain pipe of suitable size & length for split AC transpotation to any distance inside the AF area as approved.(ii) Charging of gas in required shall be measured and paid seperatly/under appropriate item of schedule A
M&L for repair of electric wiring, PCB Circuits , relays,contactor etc and replacment of defective wiring of Automatic Voltage Stablizer of 1/2/3/5KVA capacity of any make and carryout minor repair of PCB by changing resistance,condensor,transistor,indicator lamp,2 way switch ,PVC insulating sleeves etc and making functional complete all as specified and directed at site.
Supply and fix in replacement AC electric condenser motor 25 Watt, 230 Volts, 1250 RPM single speed for water cooler complete all as specified and directed
Supply and fix in replacement AC electric condenser motor 30 to 35 Watt, 230 Volts, 930 RPM single speed for water cooler complete all as specified and directed
S&F in replacement NRV suitable for 40/80 Ltr capacity water cooler storage type as per existing Make and Model.
S&F in replacement chromium plated push/lifting cock, 15 mm, made up of brass and suitable for 40/80/150 Ltr capacity storage type water cooler as per existing Make and Model..
Removing the unserviceable condenser fan motor from the Water cooler of 40/80/150 Ltr capacity and M&L for rewinding of condenser fan motor of capacity 1 / 30 or 1 / 32 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, in position connecting up all including testing and refixing complete all as specified and directed.
M&L for opening body of water coolers, taking out cooling tank to rectifiy leakage of refrigerant tube/condensor and refixing the same after carryout necessary repairs, including leakage test, filling insulation material and clamping with GI strip complete all as specified and directed.
M&L for Disconnecting,taking down and removing of ceiling fan / Exhaust fan / wall mounting fan of any description, any sweep and from any position / locations and connecting up from ceiling rose or connector to ceiling fan, necessary oiling and greasing including supplying nuts, bolts, canopy, down rod, clamps, capacitor and replacement of unserviceable parts if any, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 sqmm 3 core multistanded PVC insulated copperwire FRLS to required length and testing at site complete all as specified and directed by accepting officer Note : The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . The rates for above items are deemed to include for transportation of fans to and from workshop if required and approved by Engr-in-charge for necessary repairs. Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' .
M&L for painting of ceiling fans / Exhaust fans / Wall mounted fans complete, in situ with synthetic enamel paint by spraying including filling cavities with fille, one coat of after cleaning dust etc and writing ceiling fan number complete all as specified and directed
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete as directed for the following Fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep
All as per Item No. 56 here in above but rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed.
All as per Item No. 56 here in above but rewinding of motor of exhaust fans of 375 mm sweep complete all as specified and directed.
All as per Item No. 56 here in above but rewinding of motor of exhaust fans of 450 mm sweep complete all as specified and directed.
All as per Item No. 56 here in above but rewinding of motor of air circulating fan/wall mounting fans of 400mm sweep complete all as specified and directed.
All as per Item No. 56 here in above but rewinding of motor of air circulating fan of 610 mm sweep complete all as specified and directed.
All as per Item No. 56 here in above but rewinding of motor of pedestal fan of 400 mm sweep complete all as specified and directed.
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :- (a) Supplying only ball bearing No 6201 complete all as specified and directed.
All as per Item No. 63 here in above but Supplying only ball bearing No 6202 complete all as specified and directed.
All as per Item No. 63 here in above but Supply only gun metal bushes of any description and size to suit existing motor shaft including remetaling grinding & polishing of fan motor shaft to required shape/size complete all as specified and directed.
All as per Item No. 63 here in above but Supplying only capacitor of capacity 2.5 mfd (PVC body) complete all as specified and directed.
All as per Item No. 63 here in above but Supplying only capacitor of capacity 4 mfd (PVC body) complete all as specified and directed.
All as per Item No. 63 here in above but Supplying only armature shaft of fans of any description and in any position complete all as specified and directed.
All as per Item No. 63 here in above but Supply only PVC canopy of any description and suitable for any type & any make of fan complete all as specified and directed.
All as per Item No. 63 here in above but Supply only rubber real of suitable size of hanging assembly with clamps complete all as specified and directed.
All as per Item No. 63 here in above but Supply only 450 mm long down rod 15 mm dia of MS tube light grade, factory made , painted & duly finished with powder coating of white colour, including necessary holes and threading etc complete all as specified.
All as per Item No. 63 here in above but Supply only blade for 1200 mm ceiling fan MS tube light grade, factory made , painted & duly finished with powder coating of white colour, including necessary holes and threading etc complete all as specified.
S & F in repairs ceiling fan regulator deluxe rotary step type 100 Watt suitable for any type of ceiling fan complete all as specified and directed.
Disconnecting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed. Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A"
Supply only the following parts for geysers 50/25 Ltrs capacity of ISI marked (Make of parts shall be as per make of Geysers) :-
Heating element 2 KW suitable for operation on 230V AC 50Hz
Heating element 1.5KW suitable for operation on 230V AC 50Hz
Thermostat 40 to 90 degree centigrade varying capactiy for 25/50 Ltrs capacity Geyser.
Pressure release valve dead weight type for 25/ 50 Ltrs capacity Geyser.
Glass wool
Red indicator/Green indicator.
Gasket set for 50 litres capacity Geyser
Gasket set for 25 Ltrs capacity Geyser.
Antivaccum valve for 25/50 Ltrs capacity Geyser.
Apparatus plate assembly/ Base assembly complete with inlet, outlet and thermostat pipes with drain plug and screws for fixing the element inclusive of clamps for holding element with nut bolts, suitable for 25/ 50 Ltrs capacity geysers, of make : Bajaj/ Racold/ Power pack / Venus or equivalent ISI marked
Fusible Plug for 25/50 Ltrs capacity Geyser.
Pressure reducing valve for 25/50 Ltrs capacity Geyser.
PVC braided flexible connection pipe for inlet and outlet water, 18" long with two chrome plated brass adaptors, nipples and rubber washers complete.
Non return valve (ISI marked) 15mm dia Make Kirloskar/Leader.
Storage tank made up of stainless steel (inner tank), suitable for 25 Ltr capacity geysers.
Storage tank made up of stainless steel (inner tank), suitable for 50 Ltr capacity geysers.
Outer shell made up MS sheet, suitable for 25 Ltr capacity geysers.
Outer shell made up MS sheet, suitable for 50 Ltr capacity geysers.
Top cover/ Bottom cover for Geyser 25/50 Ltr capacity, as required on site, duly painted with white enamel paint all as specified.
Bottom cover for Apparatus plate of Geyser 25/50 Ltr capacity, as required on site, duly painted with white enamel paint all as specified.
S & F in repair/ replacement flexible round type PVC sheathed copper cable of size 1.5 sqmm 3 core complete all as specified and directed by Accepting officer
S & F earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts all as specified and directed.
Supply and fixing Brass float valve high pressure with polythene float and fly nut complete screwed for GI iron pipe of size 25 mm dia
Supply and fixing Brass float valve high pressure with polythene float and fly nut complete screwed for GI iron pipe of size 20 mm dia
Servicing of solar water heater upto 300 Ltrs capacity including checking serviceability of individual components and replacement of worn-out fasteners, gaskets, washers accessories, inspection of the entire system, cleaning of Sacrificial Anode, rectification of any leaks, tightening of electric loose connections etc,. and making system operational. Note : (1) Spares will be measured and paid separately under relevant item of Sch "A" (2) Any other spare which is not included in Sch but needs replacement shall be born by tenderer without extra cost. (3) The Servicing of Solar Water Heaters will be done Quarterly and the tenderer shall submit the Schedule of Servicing one week prior to cleaning and after completion the tenderer shall obtain Signature from MES NCO/Occupant and submit it to Engr-in-Charger for payment.
Supply only Heating element of 2 KW suitable for solar water heater electrical for supply of 230 V complete all as specified and directed by Engr-in-charge
Supply only Solar water tube for the solar water heaters suitable for the existing one complete all as specified and directed by Engr-in-charge
Supply and fixing in any length CPVC pipe of size 20 mm dia SDR 11 with fittings,fixed to wall/ceiling/floors in required length complete including making good of disturbed surfaces all as specified and directed by Engineer-in-Charge.
S&F stop valves, cast copper alloy, ISI marked, screwed down high pressure with crutch of butter fly handle, fancy type, chromium plated, with long shank and cup, screwed both ends for iron pipes of for union for 15 mm bore fixed in repair complete all as specified and directed
M&L for repair of desert cooler of any type and capacity and of any make and making necessary replacement of unserviceable and defective items complete all as specified and directed by engr-in-charge
S&F in replacement of electric pump motor 1/80 HP single phase 230 Volts AC 50 Hz including connecting and testing etc complete suitable for desert cooler.
S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 300 mm Sweep
S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 350 mm Sweep
S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 400 mm Sweep
S&F in replacement of Swing motor single phase 230 Volts AC 50 Hz including connecting and testing etc complete suitable for desert cooler.
S & F in replacement wood wool /grass pads of approved quality and size alongwith square mesh of any size as required on ground to suit the existing door size of desert cooler.
S &F in replacement of plastic fan blade 3/4 wing suitable for motor 1/8 HP of desert cooler.
S & F in replacement of 5 Amps top 3 pin incl 3 mtr 2.5 Mtr flexible copper wire suitable for desert cooler
S&F in replacement of control switches set of desert cooler as per existing sample
S&F PVC transparent pipe set complete for distribution of water of desert cooler (having droping elbow -3 Nos, distribution 3 way ) as per existing size, including clamping by screw/strip all as specified and directed.
S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
Abhishek Enterprises
Ashok Electric and Electronics
M/s Bombay Novelty Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .