EE (EM SHP) office Kund Guptkashi UJVNL
EE (EM SHP) office Kund Guptkashi UJVNL-246439
Construction of one number 33 kV Bay with SCADA integration at existing 33/11 kV substation Ukhimath of UPCL in tehisil Ukhimath, district Rudraprayag, Uttrakhand
2026_UJVN_94606_1
02/EE(EM-SHP)/KG-II/2026-27
Open Tender
Electrical Works
Item Rate
40 days
Ukhimath Uttarakhand
As per Tender document
2 documents required · 2 mandatory
₹5,900
GM (SHP) UJVNL Pragatipuram, Rishikesh
₹1.2 L
14 May 2026
23 Apr 2026
11 May 2026
23 Apr 2026
8 May 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design of earthmat, switchyard equipment, LRMP including drawings. | - | No. | - | - |
| 2 | Outdoor Porcelain Clad 33 kV Tripel pole Vacuum Circuit Breaker of ratings 36 KV, 2000Amp, 50 Hz, 24 V DC Tripping coil (including essential spare parts in set) | - | No | - | - |
| 3 | Off load 33 kV Double break Centre post rotating gang operated 3 pole outdoor, Up to 1500 A, 50 Hz ±5% manual operated, upright on GI Mounting Structure, terminal connector of bimetallic clamp for panther Bus isolator | - | No | - | - |
| 4 | 33 kV Current transformer out door oil cooled, Core IV, ratio 350-700/1-1-1-1A, burden10vA, accuracy 0.2s,0.2s,0.5,PS, short time Current 25 kA for 3 Seconds, Insulation level 70kVrms/170kVp, highest System voltage (Um) 36 kV, CU wound. | - | No | - | - |
| 5 | Outdoor Voltage Transformer, rating 33 kV/110 50 Hz, 3 Core, oil cooled, burden 50 VA, Accuracy 0.2-.02- 3P, Voltage factor 1.2 time continous and 1.9 time for 30 Seconds, Insulation level 70kVrms/171kVp, highest System voltage (Um)36 kV. | - | No | - | - |
| 6 | Supply of 33 KV, 10kA class III, Gapless type metal oxide gapless outdoor,at 5000 amp 80 kV peak total creapage distance 900 mm (25mm/kv) cyclometric type surge counter non reset, one counter/surge type of current meter, lightning arrestors. | - | No | - | - |
| 7 | IP 65 rated out door type Line Relay & Metering Panel having trip circuit supervision for line 95, high speed trip relay for line fault 86L, instantaneous/ IDMT over current / earth fault protection 50/51/51N, distance protection 21, DMS (Digital metering system etc. which is essential for line and equipment protection. | - | No | - | - |
| 8 | Earthing material and GI flates as per Design./coppre type Chemical earthing (cooper strip chemical earth rod length 1.5 Mtr) | - | Set | - | - |
| 9 | GI Structure for All Switchyard equipment. | - | Lot | - | - |
| 10 | AL 59 Panthor Conductor fittings which is essential for connecting conductor with equipment and bus bar etc as per design | - | Lot | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
TenderDocument.pdf
Tender Documents • 1.52 MB
BOQ_111946.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .