Loading…
Loading…
Tender ID
Tender Value
₹2.3 L
EMD Value
₹5,678
Closing Date
17 Mar 2026, 6:00 pmClosed
AEE
AEE,PWD Ele.SDN,Tvpm
GENERAL-Govt. taluk Hospital Attingal-SITC of Air conditioning unit in new x-ray unit room in OP Block at Taluk Hospital Attingal. Electrical AC Work.-Electrical AC Work-1
2026_PWD_845846_1
ESDT/ET-291/2025-26
Open Tender
Electrical Works
Percentage
180 days
PWD Electrical Sub Division, TVPM
Please refer tender documents
6 documents required · 6 mandatory
₹555
₹5,678
10 Mar 2026
10 Mar 2026
19 Mar 2026
10 Mar 2026
17 Mar 2026
10 Mar 2026
ac conditioning work
OD246964/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete with indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/ Bluestar:- 1.0TR single phase Inverter split A/C unit
OD246896/2025-2026:Supplying, installation, testing and commissioning of following nominal cooling capacity and ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments complete wit indoor unit ,outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410 / R32 refrigerent gas, 230V,50 Hz, single phase AC supply, capable of performing :- a. Cooling b. Dehumuidifying.c. Air Circulating.d. Filtering including providing wireless remote control unit, 3 metre copper refrigerent piping , wiring, drain pipe for condensate drain water all insulated with nitrile tubing from indoor unit complete . Make : Hitachi / Daikin/Mitsubishi/ Carrier/ Bluestar:- 2.0TR single phase Inverter split A/C unit
OD246965/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
OD246541/2025-2026:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.3/8"(9.52mm) and 5/8"(15.8mm) 22 gauge .
OD234818/2025-2026:Supply and installation for the Outdoor unit stand of Single phase 1 TR/1.5 TR/2TR Wall mounting split A/C unit.
OD234825/2025-2026:Supply and Fixing of 3 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 250V (make V-GUARD or its equivalent
OD234824/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 250V (make V-GUARD or its equivalent
OD234873/2025-2026:Supply and fixing 25mm dia PVC drain pipe and along with all required accessories in suface/recess including cutting the wall and making good the damages etc as required
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1428718.xls
BOQ • 0.32 MB
mom.pdf
Tender Documents • 0.19 MB
sc.pdf
Tender Documents • 0.08 MB
sbd.pdf
Tender Documents • 1.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .