| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 CrAccepted-AOC | ₹18.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹19.0 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹19.0 Cr | L2 | Rejected-Finance Rejected due to L2 |
| 3 | L3₹20.0 CrRejected-Finance | ₹20.0 Cr | L3 | Rejected-Finance Rejected due to L3 |
| 4 | L4₹22.4 CrRejected-Finance | ₹22.4 Cr | L4 | Rejected-Finance Rejected due to L4 |
| 5 | L5₹22.6 CrRejected-Finance | ₹22.6 Cr | L5 | Rejected-Finance Rejected due to L5 |
Tender Value
₹18.1 Cr
EMD Value
₹12.3 L
Closing Date
17 Oct 2022, 6:00 pmClosed
CE JODHPUR ZONE
HQ CE JODHPUR ZONE
PROVN OF OFFRs, JCOs / ORs DEFI MD ACCN AT BHUJ MIL STN (JOB NO 005/AMWP/12C/2021-22)
2022_MES_514780_2
800561/BHUJ/E8
Open Tender
Civil Works
750 days
BHUJ
As per tender
9 documents required · 9 mandatory
₹3,000
GE (A) Bhuj
₹12.3 L
Yes
30 Jun 2023
9 Sept 2022
19 Oct 2022
9 Sept 2022
17 Oct 2022
3 Oct 2022
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 27
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 28
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 29
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 34
Lump sum price worked out by the contractor for "ROAD & FOOT PATH" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 36
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 38
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 40
Lump sum price worked out by the contractor for "COMPOUND WALL, CHAIN LINK FENCING & GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 43
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 44
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 48
Lump sum price worked out by the contractor for "SOLAR HOT WATER" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 49
Lump sum price worked out by the contractor for "DG SET" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 50
Sch 'A' PART-XIII (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
INTERNAL WATER SUPPLY (OFFICERS QTR) S&F 15 mm bore, fancy type, CP brass bib cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar QUEEN SERIES Cat No QQT-7037 or technocommercial equivalent of any make specified in Appx 'B'.
S&F 15 mm bore, fancy type, CP brass angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar QUEEN SERIES Cat No QQT-7053 or technocommercial equivalent makes as per Appx 'B'.
S&F of CP wall mixer 3 in 1 system including 1.5 m long tele shower and overhead shower of size 150x150 mm with wall flange ISI marked complete all as specified and directed. Make - Jaquar QUEEN SERIES Cat No 7281 or technocommercial equivalent of any make specified in Appx 'B'.
S& F overhead shower 150x150 mm of ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and directed. Make - Jaquar QUEEN SERIES Cat No 35495 or technocommercial equivalent makes as per Appx 'B'.
S&F 15 mm bore CP cast copper alloy body mixer sink cock with hot & cold mixing valves & casted central spout complete all as specified and directed. Make - Jaquar QUEEN SERIES Cat No QQT-7309 or technocommercial equivalent makes as per Appx 'B'.
S&F health foucet with 1200 mm long flexible mild steel tube 80 mm dia with wall hook complete all as specified and directed. Make - Jaquar QUEEN SERIES Cat No ALD-573 or technocommercial equivalent of any make specified in Appx 'B'.
S&F two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed. Make - Jaquar QUEEN SERIES or technocommercial equivalent of any make specified in Appx 'B'.
INTERNAL WATER SUPPLY (JCO's / OR's QTR) S&F 15 mm bore, fancy type, CP brass bib cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent of any make specified in Appx 'B'.
S&F 15 mm bore, fancy type, CP brass angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent of any make specified in Appx 'B'.
S&F of CP wall mixer 2 in 1 system with central spout and connection for overhead shower with divertor lever ISI marked complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent of any make specified in Appx 'B'.
S&F overhead shower 100 mm dia of ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent of any make specified in Appx 'B'.
S&F 15 mm bore CP cast copper alloy body mixer sink cock with hot & cold mixing valves & casted central spout complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent of any make specified in Appx 'B'.
S&F two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed. Make - Jaquar ESSCO SERIES or technocommercial equivalent of any make specified in Appx 'B'.
INTERNAL ELECTRIFICATION S&F T.V./Telephone Socket Outlet, including M.S. Box of size 100x100x65 mm with cover plate complete all as specified and directed
S&F energy saving 9 Watt LED bulb with luminous efficiency 100 lumen/watt, CRI > 80, complete all as specified and directed.
S&F exhaust fan of 250 mm sweep made of steel body suitable for SP 230/250 V, 50 Hz, RPM 1200 complete with louvers shutters including fixing/grouting of frame in wall and cutting opening complete and connecting with and including connecting up with three core twisted flexible copper conductor cable of 1.0 sq mm size cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed.
S&F exhaust fan of 300 mm sweep made of steel body suitable for SP 230/250 V, 50 Hz, RPM 1200 complete with louvers shutters including fixing/grouting of frame in wall and cutting opening complete and connecting with and including connecting up with three core twisted flexible copper conductor cable of 1.0 sq mm size cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed.
Supplying, installation , testing and commisioning , factory made, CPRI approved LT panel, wall mounted board made of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof, with front opening hinge door and locking arrangment mounted on suitable MS flat iron panel body duly grouted on wall, having Aluminium bus bar 20 mm x 10 mm for phase and netural insulated with PVC sleeves, fixing of single phase prepaid energy meter of suitable capacity 06 Nos. copper lugs, spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, PVC shrinkable sleeves, nuts and bolts, washers etc, and suitable size single core copper wire connections, suitable compartmnets and epoxy powder spray paint with primer complete including fixing of smart single phase two wire dual source prepaid energy meter IS 16444: 2015 (Reaffirmed 2020) marked in existing meter board/floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 volts accuracy class 1.0 alongwith parellel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual sorce registration with grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition all as specified by Engineer-in-Charge and consisiting of following accessories:
INCOMING: (a) TPN MCB 100 amp 415 volts, 25 KA breaking capacity-01 No (b) R-Y-B-phase LED indicating lamp-03 Nos (c) 200 Amp TPN main aluminum bus bar-outgoing (d) MCB SPN 40 Amp 10 KA-06 Nos (e) copper cable 6 sqmm wire and open terminals for all feeders and provide 2 Nos earth link on both side.. Note: Qtr No to be mentioned in respective meter on acrylicplate
Supplying, installation , testing and commisioning , factory made, CPRI approved LT panel, wall mounted board made of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof, with front opening hinge door and locking arrangment mounted on suitable MS flat iron panel body duly grouted on wall, 415 Volts 3 Phase, 4 wire AC 50 HZ having Aluminium bus bar 20 mm x 10 mm for phase and netural insulated with PVC sleeves, space for fixing three phase prepaid energy meter of suitable capacity 04 Nos. copper lugs , spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, PVC shrinkable sleeves, nuts and bolts, washers etc, and suitable size single core copper wire connections, suitable compartmnets and epoxy powder spray paint with primer complete including fixing of smart three phase four wire dual source prepaid energy meter IS 16444: 2015 (Reaffirmed 2020) marked in existing meter board/floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 volts accuracy class 1.0 alongwith parellel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual sorce registration with grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition all as specified by Engineer-in-Charge and consisiting of following accessories:
INCOMING: (a) TPN MCCB 63 amp 415 volts, 25 KA breaking capacity-01 No (b) R-Y-B-phase LED indicating lamp-03 Nos (c) 100 Amp TPN main aluminum bus bar-outgoing (d) MCB TPN 40 Amp 10 KA-04 Nos (e) copper cable 6 sqmm wire and open terminals for all feeders and provide 2 Nos earth link on both side. Note: Qtr No to be mentioned in respective meter on acrylicplate
M&L for sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and two run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH (RYBN) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 32 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Four runs of cable with two run of earth wire and one run of PVC conduit shall be measured & paid for as one length.
S&F LED Security light fitting 1x35 W made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 10 KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT3000-6000 CRI greater than 70, input power 35 W system with 100 lumens per watt output operating voltage 160-260V with connection by three core PVC insulated multistaranded copper conductor sheathed cable of size 1.0 sqmm fixed with & including bracket made of GI Pipe 25 mm bore light grade, 1.20 m long bent to shape required with 2 Nos MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed.
Note for item No 34.00: (1) The LED lights shall have gurantee for 5 Years from date of completion of contaract , any defects noticed during this period shall have be rectified / Parts replaced immediately, security amount of 10% of the cost of the item shall be retained with the Deptt till end of the guarantee period. (ii) LED light manufacturer lab shall be accredited to NABL.
S&F smart single phase two wire dual source prepaid energy meter IS 16444: 2015 (Reaffirmed 2020) marked with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 volts accuracy class 1.0 alongwith parellel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual sorce registration with grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition all as specified by Engineer-in-Charge.
ROAD & FOOT PATH M&L for 150 mm thick WMM (Wet Mix Macadam) (compacted thickness) laid in two layers of 75mm thick each conforming to grading given in table 400-13 & physical requirement given in table 400-12 spread by mechanical means & rolled by using 8-10 ton vibrator power roller over compacted sub grade surface of soling as specified in clause 406 3.5 of MORTH specification and necessary lateral support and formwork if required complete all as specified and directed.
M&L for preparing bituminous surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes, arrows tec. and the like n. exc. 15 cm wide on roads pavements with hot applied thermoplastic road marking paint of approved colour confirming to BS 3262-1989 with 20% glass beds (intermixed) spread and laid by automatic mechanical machine engine at approximate temprature 160 dfegree celcius with special applicator machine as per manufacturers instruction complete all as specified and directed.
COMPOUND WALL, CHAIN LINK FENCING & GATE S&F Cast Iron (CI) wheel as rollers of 80 mm dia for gates complete.
EXTERNAL WATER SUPPLY Supply and lay pipe ductile iron both ends flanged and drilled, ISI marked, S/S including specials, class "K-9'', with internal cement mortar lining in nominal bore dia of 150 mm (6'') dia complete all as specified and directed.
Supply and lay pipe ductile iron both ends flanged and drilled, ISI marked, S/S including specials, class "K-9'', with internal cement mortar lining in nominal bore dia of 100 mm (4'') dia complete all as specified and directed.
Supply and lay 25 mm bore UPVC pipe (SCH-40) supplied and laid complete including fittings, tee joints, reducers, sockets complete all as specified and directed.
Supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with Bronze wedge ring on both side, gland packing, class - PN 1.6 with flanged ends drilled suitable for bore of pipe 100 mm ISI marked (IS:14846:2000) having S.S. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed.
Supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with Bronze wedge ring on both side, gland packing, class - PN 1.6 with flanged ends drilled suitable for bore of pipe 150 mm ISI marked (IS:14846:2000) having S.S. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed.
M&L for cutting of existing DI/CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessary excavaton and earthwork, dewatering etc, if any involved, complete all specified and directed for 80mm to 100mm bore of pipe complete all as specified and directed.
Supply, install, test and commissioning self priming centrifugal pump set 7.5 HP Foot mounted (B-3), fan cooled motor, S1 Duty suitable for 415V, 3 phase, 50 Hz, insulation class F, ambient of 50 C conforming to IS 12615:2011, IEC 60034-30-2008 and IP protection complete all as specified and directed,
Supply, install, test and commissioning of star delta starer suitable for 7.5 HP Motor with thermal protection and adjustment range and single phasing protection, over load and under load protection, over voltage and under voltage protection, short circuit protection, test to trip facility complete all as specified and directed.
S&F foot valve, flanged end, conforming to IS 4038, 150 mm dia complete all as specified and directed.
S&F cast iron air valves with two air outlets, 50mm dia conforming to IS 14845 and fixing to cast iron water supply mains of dia 50 mm all as specified and directed.
S&F reflux valve, CI with D/F, ISI mark, as per IS 5312, with bypass arrangement, 150 mm dia complete all as specified and directed.
S&F flexible rubber expansion joint of suitable dia for motor inlet and outlet dia to reduce vibration and dampen sound transmission of standard ANSI 150, complete all as specified and directed.
M&L for Construction of new PCC solid Masonary valve chamber of size 900 X 900 X 900 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 50 mm X 50 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
M&L for Construction of new PCC solid Masonary valve chamber of size 600 X 600 X 600 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
EXTERNAL ELECTRIFICATIONS S&F HT 11 KV, 200 Amps, outdoor type gang operated air break switch, FRP type, triple pole with earthing switch rotating type for vertical operation, mounted on steel frame with insulators with operating mechanism worked from ground level consisting of operating rod of 25mm bore medium grade GI pipe of suitable length from ground level including locking arrangement with pad lock with three Nos of keys including all accessories such as nuts, bolts, washers and locking arrangemrnt comolete all as specified and directed.
Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box CPRI approved factory fabricated outdoor cubical/KIOSK type totally enclosed outer cage made out of 3.15mm thick sheet metal and inner compartments of 2.0mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6mm suitable for operation on 3 phase 4 wire system with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrengement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes of prevent ingress of water/vermin etc, IP 54, air vents, inside the enclosure, the required nos of holes to be fixed wit chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/externally of approved colour with PCC foundation and aluminium bus bar for three phase and neutral mounted on epoxy insulator (R,Y,B,N) - 01 set with heat shrinkable coloured sleeves including connecting the following (Main Panel):-
All as per item No 54.00 hereinbefore but LT panel consisting of following:-
All as per item No 54.00 hereinbefore but LT panel consisting of following:-
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to and including earth lead of galvanized strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I with connected to earth test point & to main switch board with & including adequate quantity of charcoal and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe fpr suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mess including necessary earth work and PCC (1:3:6) type C1 for earth pit and 40mm thick precast RCC cover in cement concrete 1:2:4 type B1, with 3 Nos 8mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and directed NOTE: Item includes the cost of earth lead and GI protection pipe up to 7.5 m. GI strip and protection pipe beyond 7.5 m shall be measured and paid for separately.
M&L for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply, fixing and testing of digital automatic street light switch of capacity 5 KW equally distributed, single phase with high and low voltage and overload protection consists of contactor, 1 No of incoming MCB of 25-40 Amps Each & circuit wiring of 10 sqmm. The circuit should also have provision for manual operation sensor along with contactor, MCBs should be enclosed in polymounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54 complete all as specified and directed.
S&F weather Proof PVC Junction Box made out of not less than 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers complete all as specified and directed.
Supply, installation, commissioning and testing of company make Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 80 KVAR in 6 steps (10 KVAR X 1 Nos fixed compensation + 10 KVAR x 2 Nos + 15 KVAR X 2 Nos + 20 KVAR X 1 Nos) complete with relays, capacitor banks for automatic operation to power factor above 0.95. The panel should be complete with TP air break contacts of capacitor contacts of duty with suitable switch gear, MPP heavy duty shunt capacitor impregnatd, having rated voltage of 440 V type with internal electrical switch gear each element as per IS 13340-1993/IS 13341-1992, IEC 60831 Part I & 2 of outdoor type double door (KIOSK type) complete with interconnections with suitable size of copper wiring, PVC insulated unarmoured cable and PVC sheath etc as required. The panel shall be made out of 3.15 mm thick CRCA shett powder coated with angle frame of size 50X50X6 mm cubical type including interconnetion wiring, indicating lamps etc conforming to IP 42 specifications including grounding of panel as per electrical standards, electrical connections shall be made by using proper thimbles/lugs, cable gland complete all as specified and directed as follows:
OUTGOING: (a) Accessories for 10 KVAR fixed compensation capacitor bank - MCB, TP, 20 Amp, 10 KA, D curve. (b) Accessories for 15 KVAR capacitor bank - capacitor duty contactor (AC6b) 15 KVAR with damping resistors which limit xinrush current, 440 volt, 3 ph, 50 Hz, coil-220 lac & MCB TP 20 Amp, 10 KA, D curve. (c) Accessories for 20 KVAR capacitor bank - capacitor duty contactor (AC6b) 20 KVAR with damping resistors which xinrush current, 440 volts, 3 phase, 50 Hz, coil-220 Lac & MCB TP 32 Amp, 10 KA, D curve. Note:- (a) Ventilating fans of required size to dissipate the heat liberated by capacitor units complete with automatic swicthing ON and OFF of fans depending upon the temperature of panel, 230 V AC, 2650 RPM, 160 Cum/h, flying leads. Panel shall have silicon based fire/heat resistance coating. fire retarding DMC/SMC filling for the opening around the busbar near to the sectional barriers and door interlocking for all compartments - 01 lot. All Accessories pre wired with suitable size copper conductor cable insulated with fiber glass insulation to with stand. (b) high temperature, housed in cubical panel (CPRI approved) made out of 3.15 mm thick MS sheet factory made duly powder coateed front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
M&L for platform for transformer of size 1.50x1.50x1.50 m including necessary surface excavation, returning filling and PCC work complete all as specified and directed.
M&L for HT cable route indicator duly painted with grey colour synthetic enamel paint two coats over one coat of red oxide primer, oval shape of size 200mm x 150mm x 6mm thick cast iron disc with letters embossed and fixed on 25mm x 25mm 5mm thick MS angle iron for 50mm long including necessary PCC in 1:3:6 type C1 using 20 mm graded stone aggeregate and 15mm thick plastering all around below ground level of size 650mm x 300mm x 250mm embedded in PCC block all as specified and directed.
Supply, fixing, testing and commissioning explusion fuse, FRP type, single pole double insulator with barrel fuse element of capacity of 50 Amps to 100 Amps for 11 KV complete all as specified and as directed.
M&L for loose filling using 40mm to 80mm stone aggregate (granite) spread to a thickness of 150mm for outdoor sub station complete all as specified and as directed.
M&L for connecting and shifting of transformer 200 KVA from E/M store yard to site location and connecting HT and LT cable on plinth complete all as specified and directed.
S&F disc type insulator, FRP grey polymer, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors,working pressure 11000 volts, complete all as specified and as directed. complete all as specified and directed.
S&F pin type FRP grey polymer, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia suitable for working pressure of 11000 volts grade for HT lines fixed on poles complete all as specified and as directed
SOLAR HOT WATER Supply, install, testing and commissioning of Solar Hot Water system, Flat Plate Collector, based on indirect transfer of heat of capacity 600 LPD with electrical heating back up of 4 KW heating element.
Supply, install, testing and commissioning of Solar Hot Water system, Flat Plate Collector, based on indirect transfer of heat of capacity 400 LPD with electrical heating back up of 4 KW heating element.
DG SET Supply install testing and commissioning of Diesel engine driven genrating set 415 Volts, 3 Phase 4 wire, engine as per IS : 10001/10002 and alteranator as per IS 13364 with inbuilt AMF panel as per details given hereinafter complete with foundation as per design, control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 15 KVA. Tools and spares complete all as specified and directed and comprising of the following :-
(a) Engine:- Diesel engine,direct injection, water cooled BHP as per manufacturer standard @ 1500 RPM suitable for 15 KVA alternator with provision of 10% over load for one hour in every 12 hour running confirming to BS 5514/ISO 3046 standard. Totally enclosed, electric start, compression ignition, 2 cylinder, inline, 4 stroke. The engine shall consists of following specification :-
The scope of supply includes: -Electrical starter motor 12V DC, Battery charging alternator - Turbo charger, pulse tuned exhaust manifold, stainless steel exhaust flexible connection -Radiator cooling,with turbo charged after cooling -Mechanical Fuel injection Pump -Electronic Governor -Dual spin-on fuel filter -Spin-on full flow lub oil filter -Residential silencer -Dry type air cleaner -Recovery bottle -Shut-off coil with safeties for LLOP/HWT -Flywheel and flywheel housing to suit single bearing alternator
(i) Alternator suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire system, conforming to BS 5000 / IS 4722. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator has the following features: -+ 1.0 % Voltage regulation (max.) in static conditions -IP: 23 Enclosure -Permissible overload of 10% for one hour in 12 hours of operation as per standards (ii) Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. The steel shall be TESO / SAIL or equivalent make
(iii) Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for a weather-proof, long lasting finish. The control panel consists of following parts: -Standard engine instrumentation -Multi function meter which measures: 1) Individual phase current (Amps) 2) Phase voltages (V) 3) Generator output frequency (Hz) 4) Engine water temperature (Deg.C) 5) Lube oil pressure (kg/cm2) and equipped with hour counter -MCCB of suitable rating -Key switch -Push button (Starter) -LED: Battery charging alternator fail indication -Current transformers -Instrument fuses duly wired and ferruled
(iv) Others:- Fuel tank suitable for 8 hours of operation -One charged battery 12V, suitable rating AH with battery leads & cable Acoustic enclosure:- The acoustic enclosure is made of 1.6/ 2 mm thick CRCA sheets and structural/ sheet metal base frame duly painted. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75 dBA at 1mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: -Specially designed to meet stringent MOEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions, -Single point lifting for easy handling, -Designed to have optimum serviceability -Air inlet louvers specially designed to operate at rated load, -Made on special purpose CNC machines for consistency in quality and workmanship, -Powder coated for long lasting service life and superior finish, -With UV resistant powder coating, can withstand extreme environments, -Use of special hardware for longer life, -Insulation material meets exacting IS 8183 specifications for better sound attenuation, -Flush styling - no projections, -Fluid drains for lube oil and fuel, -Fuel filling point. (v) One set of accessories (As per manufacturer's instructions) :- (a) Level indicator on fuel tank (b) Drain plug (c) MS class "C" piping, suitable dia and length for fuel inlet from tank to engine as per manufacturers instructions. (d) Fuel strainer and fuel tank with air vent. (e) Battery heavy duty 12 Volts lead acid type fully charged, indication of high flow charging changed. - 01 Nos (f) Cable connection from alternator to DG set control panel as directed
ARBORICULTURE Digging of pit n. Exc 0.25 cum in any type of soil including removal and filling back tp pit with suitable growing media like red earth by treating with farm yead manure in the ratio (3:1) fertilizers and pesticides (i.e. Bevation and neem cake BHC 10% linson dust. Thimment or phorate, manure super and vermicompost) and making up the trench area to proper level including supply and planting tree plants of species of height not less than 3 feet as Neem (Azadiracha indica) complete all as specified and directed.
Ditto all as per item No 72.00 hereinbefore but Kesher Mango
Ditto all as per item No 72.00 hereinbefore but Cheeku
Ditto all as per item No 72.00 hereinbefore but Jamun
Ditto all as per item No 72.00 hereinbefore but Pomegranite
Pronv of MS Tree guard 450 mm dia, 1.50 m high with MS wiremesh of size 78mm x 37mm and 2mm dia of wire and MS angle iron 20x20x3mm verticals (3 Nos) 1.95 m long, 30 cm burried in ground & MS flats 14x3 mm around the tree guard (3 Nos @ top, middle and bottom) equally spaced and embedded vertical angles in PCC 1:3:6 Type C-1 including excavation in post holes and removal of excavated soil to a n. exc. 50 m and applying two coat of synthetic enamel paint including one coat of red oxide primer to tree guard and all as specified and directed.
Maintenance of planted trees and lawn area grass for two year after certified date of completion issued by GE, by employing one experienced mali per day. The maintenance shall includes the following. (a) Periodical de-weeding of unwanted vegetation growth around the plants/lawn area (b) Watering all the trees/plants/grass and soil with required for proper growth. (c) Periodical prunning the shrubs. (d) periodical lawn mowing. (e) Treating the trees/plants grass and soil with required quantity of approved manure, pesticides and fertillizer including necessary toping of red earth. (f) Replacement of dried/dead plants/grass/trees. (g) Hose pipe to be arranged by the contractor. (h) water shall be supplied by Deptt free of cost only for watering to plants.
RAGHUSONS INFRA ENGINEERING PVT. LTD
RAMDEV CONSTRUCTION CO.
Agarwal Jagdish Construction Company Private Limited
Jeet Construction
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
SOOD ASSOCIATES PVT LTD
Hariom Projects Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid