Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | ₹26.2 L Quoted ₹26.5 L | L1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L2₹27.4 L+₹84,856.60 (3.20%)Rejected-Finance | ₹27.4 L+₹84,856.60 (3.20%) | L2 | Rejected-Finance Over all rates are higher than L1. |
| 3 | L3₹28.8 L+₹2.3 L (8.53%)Rejected-Finance | ₹28.8 L+₹2.3 L (8.53%) | L3 | Rejected-Finance Over all rates are higher than L1. |
| 4 | L4₹30.6 L+₹4.0 L (15.3%)Rejected-Finance 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | ₹30.6 L+₹4.0 L (15.3%) | L4 | Rejected-Finance Over all rates are higher than L1. |
| 5 | L5₹34.5 L+₹8.0 L (30.0%)Rejected-Finance | ₹34.5 L+₹8.0 L (30.0%) | L5 | Rejected-Finance Over all rates are higher than L1. |
Tender Value
Refer Docs
EMD Value
₹86,500
Closing Date
26 Jan 2021, 6:00 pmClosed
CWE (AF) Bareilly
CWE (AF) Bareilly
SPECIAL REPAIR/REPLACEMENT OF OVERHEAD LINES TO UNDERGROUND CABLE AND CONNECTED ACCESSORIES OF CERTAIN PLACES IN DOMESTIC AREA AT AF STN BAREILLY
2020_MES_397093_3
SPL REP of OH LINES TO UG CABLE AT BLY
Open Tender
Electrical Maintenance Service
Item Rate
180 days
Bareilly
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bareilly
₹86,500
Yes
19 Feb 2021
5 Jan 2021
28 Jan 2021
5 Jan 2021
26 Jan 2021
14 Jan 2021
Amount
Supply and laying 240 Sqmm 3.5 core of 1100 Volts grade heavy duty XLPE armoured cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor complete all as specified and directed. Make : R R kable, Finolex , Polycab, RPG (ASIAN), NICCO
Supply and laying or fixing or passing through pipe size 50 Sqmm 3.5 core of 1100 Volts grade heavy duty XLPE armourade cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor complete all as specified and directed. Make : R R kable, Finolex , Polycab, RPG (ASIAN), NICCO
Supply and laying or fixing or passing through pipe size 35 Sqmm 3.5 core of 1100 Volts grade heavy duty XLPE armourade cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor complete all as specified and directed. Make : R R kable, Finolex , Polycab, RPG (ASIAN), NICCO
Supply and laying or fixing or passing through pipe size 16 Sqmm 4.0 core of 1100 Volts grade heavy duty XLPE armourade cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and over all PVC sheathed nominal cross section stranded conductor complete all as specified and directed. Make : R R kable, Finolex , Polycab, RPG (ASIAN), NICCO
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out in soft loose soil for laying of cables, foundation of poles, and stay assembly complete all as specified and directed. Note: (i) Retrieved bricks shall be stacked neatly and useful bricks shall be reused in the work.
Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed. Note: Punned thickness only will be measured & paid.
S&L well burnt sub class ‘B’ bricks (using old size brick) laid in trenches above sand cushioning for cable protection complete.
Horizontal boring under Road, pavement, hard standing complete for inserting GI pipe light grade of size 80/100mm dia all as specified and directed. Note :- GI pipe shall be measured and paid seperately
M & L for 50 mm dia of Tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and as directed.
M & L for 80 mm dia of Tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and as directed.
M & L for 100 mm dia of Tubes light grade galvanised with all fitting laid in trenches or inserting in horizontal boring complete all as specified and as directed.
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of excavated soil to a distance not exceeding 50 Mtr depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed.
Dismantling of ACSR or AAC conductors from existing O/H line complete all as specified and directed.
Dismantling earth wire from existing O/H line complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc complete all as specified and directed.
Design, supply, erection, testing and commissioning of outdoor type cubical Feeder Pillar of overall size not less than 1600mm width x 1000mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 1000 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15 mm thick CRCA mild steel sheet and 3.15 mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 1000 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
INCOMING :- S & F Air Cercuit Breaker braking capacity 50 KA 4 pole 630 Amps 415 Volts MDO type (manual Draw out type) with Microprocessor based MP4LSIG (With protection of over Load, SC and Earth Fault) realese with Digital LCD display with Battery Backup complete all as specified and directed Note : in built protection release shall have following prorections nad Standerds (i) Adjustable over load current (ir) setting from 40% to 100% of rating of ACB (in) over load time setting (tr) from 5-10-20 (ii) Short circuit setting (isd)from 1.5 to 10 Time of ir setting, short circuit time delay adjustable from 0 to 1 sec. (iii) Instantaneous (li) proction with an adjustable pick-up from 2 to 15 in and an off position. (iv) In built of fault setting adjustable from 25% to 100% In. (v) Over voltage, under voltage & voltage unbalance function. Make :Model No : Legrand DMX3P4, ABB EMAX With PR 122, Siemens 3WL with 660 release. OUTGOING :- (i) MCCB 320 Amps (36 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 04 Nos, (ii) MCCB 80 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 02 Nos (iii) MCCB 40 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 01 No For Street Light Make : LEGRAND /SCHNEIDER / ABB
MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS) Panel Mounted Digital Multi Function Energy Meter 3 lines LCD diplay in 96mm x 96 mm accuracy class 1.0 3 phase 4 wire basic with RS 485 Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 600/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE
CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.Note : (1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1600mm width x 1000mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 600 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
INCOMING :- (i) MCCB 320 Amps (36 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, -01 No. Make : LEGRAND /SCHNEIDER / ABB OUTGOING :- (i) MCCB 100 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 04 Nos (ii) MCCB 80 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 04 Nos (iii) MCCB 40 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 01 No Make : LEGRAND /SCHNEIDER / ABB
MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE Digital Ammeter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 N0 Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 300/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE
CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.Note : (1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of outdoor type cubical Feeder Pillar of overall size not less than 1200X1000 (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 400 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables the Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 400 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
INCOMING :- (i) MCCB 250 Amps (36 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, -01 No. Make : LEGRAND /SCHNEIDER / ABB OUTGOING :- (i) MCCB 100 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 04 Nos (ii) MCCB 80 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 01 Nos
MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE Digital Ammeter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 N0 Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 300/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE
CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.Note : (1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Design, supply, erection, testing and commissioning of outdoor type cubical Feeder Pillar of overall size not less than 1600X1000 (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables .The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 600 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.
INCOMING :- (i) MCCB 250 Amps (36 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, -01 No. Make : LEGRAND /SCHNEIDER / ABB OUTGOING :- (i) MCCB 80 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 05 Nos (ii) MCCB 40/25 Amps (25 KA) 4 Pole Adjustable with thermal megnitic protection unit for O/L and short cecuit protection, thermal Adjustable 0.8 to 1.0 In Megnetic Adjustable, - 03 Nos
MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS) Digital Volt Meter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE Digital Ammeter 0-500 Volts (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 N0 Make : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 300/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE
CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.Note : (1) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (2) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (3) All the inner / outer doors should have locking facility through castle locks (4) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (5) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (6)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm (7) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (8) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process.
Make of LT Panel for item No 17 to 20 : Tricolite / L&T / ITE Gurgaon / Salabh India Ltd. / HPL / Universal Switchgear Control
S & F of shock proof, rust proof, fire retardant non transparent Kiosk pole box of size 310x210x120 mm made of Engeineering plastic one piece moulding, for out door duty, with four Nos. of insulated aluminium bus bar of 60 Ampere capacity mounted on unbreakable insulators, 10 Ampere MCB SP with aluminium lugs of suitable size upto 50 sqmm including 02 Nos. 40x3mm flat iron clamps duly painted both side with two coats of synthetic enemel paint over a coat of red oxide primer, necessary suitable size nut-bolts, washers etc. including dismantling unserviceable one complete all as specified and as directed.
S&F three core PVC insulated flexible cable cord 1.5 sqmm multi stranded copper conductor flexible cables 1100 Volt grade complete and making connection from pole box to Street light and Flood Light Fittings all as specified and directed. Make: Finolex, Polycab, Havells, Plaza & Grandlay.
Taking down old Unserviceable LT Cable from LT over head line to Building TPN DBs complete all as specified and as directed. Note :- Cable retrieved will be deposited in MES store Yard.
Laying only bricks (using old size brick) obtained under item No. 5 of BOQ laid in trenches above sand cushioning for cable protection complete.
Supply and Fixing STREET LIGHT Timer 415 V, 8 KW rating for outdoor luminaries. Automatically switching ON/OFF (nature switch) VMS Series for LED Streets Control (with voltage Monitoring system/device integrated VMS Modules for three Phase with enclosure, conforming to IP 54 having company programmed, automatic group control of out door luminaries suitable for three phase load upto 8 KW complete all as specified and directed Make: Healer Enterprises. Model No SWADEEP-02EC 08W3P-VMS
Cutting of depth of 100 mm in to Concrete floor/Plinth protection and Trimming surface up to not exeeding 40 CM in width for laying of cable and making good with PCC 1:3:6 Type C2 20 mm Graded agregade for repair and Making good complete all as specified and directed.
VINYAK TRADERS
LAMBA BUILDERS
K.S.Traders
M/S HINA ELECTRICALS
M/S VIRAT CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .