Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.2 L+₹7,600 (0.83%)Rejected-Finance DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L2 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | PAVANI INFRAS L1 | BEST ENGINEERING L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, installations, testing and commission of CPRI tested Controlled Early Streamer Emission type (ESE) lightning conductor fully autonomous type having Stainless steel central pick up rod, full electrical continuity between the tip and the earth point complete all as specified and as directed.
Note:- It shall be fully autonomous (no battery, no external power supply required) and shall Collect energy through streamer emission controlled with an electronic device that detects the lightning and trigger a streamer (3,5KV and 20A). It shall Manufactured as per CPRI Requirements / Rating for which tested 5+ve and 5-ve lightning impulse current (8/20ms) of 70KA temperature in degree Celsius 25 degree, atmosphere Pressure in mm of Hg680, relative humidity rh%77 & Indian standard. Test meter must be available to check the functionality of the ESE Lightning arrestor. | 4 | Each Job | 60,000 ₹2,40,000 Lowest | 75,000 ₹3,00,000 |
| 2.00 | Supply and fix 5 mtr elevation pole made of GI with a dia of 40mm with a M20 thread (20 mm major diameter and a 2.5 mm coarse pitch) at the top to fix the lightning conductor including Bracket, clamps and all required fixing equipments complete all as specified and as directed. (HSN Code : 73063090)
Note:- The quoted rate shall be inclusive for necessary Base plate and PCC block for embedding GI pipe complete as per standard engineering practice. | 4 | Each | 15,000 ₹60,000 | 12,000 ₹48,000 Lowest |
| 3.00 | Supply, laying and fixing of 50mm² insulated multistranded copper cable as down conductor (HSN Code : 8544).
Note:- Electrically insulated PVC sheathed protected covering shall be provided over the down conductor up to 02 meters from the ground level / roof level. The quoted rate shall be inclusive for this provision | 160 | RM | 1,000 ₹1,60,000 | 600 ₹96,000 Lowest |
| 4.00 | M&L for Chemical earthing with copper earth plate electrode of size 900 X 600 X 5mm buried directly in ground, earth pit not less than 2.25 mtr depth below ground level (1.25 mtr width) and with top edge of the plate not less than 1.35 mtr below ground level connected to copper earth lead strip of size 50mX6 mm (length not more than 7.5 mtr and connected to test point) by means of bolts, nuts , check nuts and washers of tinned copper / brass in addition to brazing of all joints including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr , Charcoal dust 250Kg, common Salt Crystal 200kg and Magnesium Sulphate Crystal 100kg to be used in pit , GI pipe light grade of 80 mm bore as protection pipe, GI pipe 25mm dia medium grade of enough length to reach just above copper plate fitted with funnel with wire mesh, along with cap and running water tap to be provided for keeping the soil wet, PCC pit with PCC (1:3:6) pre cast chamber of internal size 40x40x30 cm and 40 mm thick RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab (42X42cm) reinforced with 8 mm dia TMT bar both ways at 100 mm C/C complete all as specified and conforming to IS 3034-2018 : Code of practice for earthing all as specified and as directed. | 4 | Each Job | 1,00,000 ₹4,00,000 Lowest | 1,10,000 ₹4,40,000 |
| 4.10Note for item No.04:- The following precautions to be observed while erecting the earth pits :- (i) The copper plate and the copper strip to be brazed. (ii) Alternate layers of charcoal and salt should be laid in the earth pit on top of the copper plate. At least five layers to be laid. (iii) After laying of five alternate layers of charcoal and salt, a 2 inch layer of magnesium sulphate needs to be laid. Balance volume of to be filled with soft soil. (iv) The chemical, salt and magnesium sulphate should never be mixed but are to be laid in layers only. (v) Ceramic spacer to be placed between the copper strip and the wall while extending the earth to the equipment. Large holes not to be drilled into the copper strip for fixing ceramic spacers. | |||||
| 5.00 | Supply and fixing six digit display lightening strike counter (IP65) at each ESE location and connection along with suitable cable to the down-conductor. | 4 | Each | 13,000 ₹52,000 | 9,000 ₹36,000 Lowest |
| 6.00 | M&L for earth plate marking made up of angle iron 25x25x3 of length not less than 1.0 mtr, (0.5 mtr above GL) fixed with MS plate of 300 x 150 mm x 2mm by welding including two coats of red oxide paint with one coat of anti corrosive paint of colour complete all as specified and as directed
Note:-
The following shall be written in marking plate with anticorrosive paint.
"Earth Pit Nos : _____
ER Value : _____
Measured on : _____
Next Due on : ____ | 4 | Each | 400 ₹1,600 | 300 ₹1,200 Lowest |
Tender Value
₹10.1 L
EMD Value
₹20,500
Closing Date
24 Dec 2025, 6:00 pmClosed
CWE(AF)Trivandrum
CWE AF TRIVANDRUM HQ SAC IAF Complex Akkulam Thruvikkal Post Trivandrum 11
82626/E8 PROVISION OF LIGHTNING ARRESTER AND ASSOCIATED WORKS AT CERTAIN OTM ACCN OF AF STATION SURYALANKA
2025_MES_742946_1
82626/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Suryalanka
CLASS E CATEGORY b(i)
7 documents required · 7 mandatory
₹500
AGE I AF Suryalanka
₹20,500
Yes
19 Jan 2026
4 Dec 2025
26 Dec 2025
4 Dec 2025
24 Dec 2025
18 Dec 2025
4 Dec 2025 - 10 Dec 2025
Amount
Supply, installations, testing and commission of CPRI tested Controlled Early Streamer Emission type (ESE) lightning conductor fully autonomous type having Stainless steel central pick up rod, full electrical continuity between the tip and the earth point complete all as specified and as directed. Note:- It shall be fully autonomous (no battery, no external power supply required) and shall Collect energy through streamer emission controlled with an electronic device that detects the lightning and trigger a streamer (3,5KV and 20A). It shall Manufactured as per CPRI Requirements / Rating for which tested 5+ve and 5-ve lightning impulse current (8/20ms) of 70KA temperature in degree Celsius 25 degree, atmosphere Pressure in mm of Hg680, relative humidity rh%77 & Indian standard. Test meter must be available to check the functionality of the ESE Lightning arrestor.
Supply and fix 5 mtr elevation pole made of GI with a dia of 40mm with a M20 thread (20 mm major diameter and a 2.5 mm coarse pitch) at the top to fix the lightning conductor including Bracket, clamps and all required fixing equipments complete all as specified and as directed. (HSN Code : 73063090) Note:- The quoted rate shall be inclusive for necessary Base plate and PCC block for embedding GI pipe complete as per standard engineering practice.
Supply, laying and fixing of 50mm² insulated multistranded copper cable as down conductor (HSN Code : 8544). Note:- Electrically insulated PVC sheathed protected covering shall be provided over the down conductor up to 02 meters from the ground level / roof level. The quoted rate shall be inclusive for this provision
M&L for Chemical earthing with copper earth plate electrode of size 900 X 600 X 5mm buried directly in ground, earth pit not less than 2.25 mtr depth below ground level (1.25 mtr width) and with top edge of the plate not less than 1.35 mtr below ground level connected to copper earth lead strip of size 50mX6 mm (length not more than 7.5 mtr and connected to test point) by means of bolts, nuts , check nuts and washers of tinned copper / brass in addition to brazing of all joints including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr , Charcoal dust 250Kg, common Salt Crystal 200kg and Magnesium Sulphate Crystal 100kg to be used in pit , GI pipe light grade of 80 mm bore as protection pipe, GI pipe 25mm dia medium grade of enough length to reach just above copper plate fitted with funnel with wire mesh, along with cap and running water tap to be provided for keeping the soil wet, PCC pit with PCC (1:3:6) pre cast chamber of internal size 40x40x30 cm and 40 mm thick RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab (42X42cm) reinforced with 8 mm dia TMT bar both ways at 100 mm C/C complete all as specified and conforming to IS 3034-2018 : Code of practice for earthing all as specified and as directed.
Note for item No.04:- The following precautions to be observed while erecting the earth pits :- (i) The copper plate and the copper strip to be brazed. (ii) Alternate layers of charcoal and salt should be laid in the earth pit on top of the copper plate. At least five layers to be laid. (iii) After laying of five alternate layers of charcoal and salt, a 2 inch layer of magnesium sulphate needs to be laid. Balance volume of to be filled with soft soil. (iv) The chemical, salt and magnesium sulphate should never be mixed but are to be laid in layers only. (v) Ceramic spacer to be placed between the copper strip and the wall while extending the earth to the equipment. Large holes not to be drilled into the copper strip for fixing ceramic spacers.
Supply and fixing six digit display lightening strike counter (IP65) at each ESE location and connection along with suitable cable to the down-conductor.
M&L for earth plate marking made up of angle iron 25x25x3 of length not less than 1.0 mtr, (0.5 mtr above GL) fixed with MS plate of 300 x 150 mm x 2mm by welding including two coats of red oxide paint with one coat of anti corrosive paint of colour complete all as specified and as directed Note:- The following shall be written in marking plate with anticorrosive paint. "Earth Pit Nos : _____ ER Value : _____ Measured on : _____ Next Due on : ____
BEST ENGINEERING (BID ID -3506544)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
Tenderdocmerged.pdf
Tender Documents • 2.44 MB
BOQ_831952.xls
BOQ • 0.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .