Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.6 LAccepted-AOC 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹74.6 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹76.9 LRejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹76.9 L | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹86.8 LRejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹86.8 L | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹89.5 LRejected-Finance | ₹89.5 L | L4 | Rejected-Finance Not lowest bidder |
| 5 | L5₹89.8 LRejected-Finance 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | ₹89.8 L | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | M/s Bombay Novelty Stores L10 | Anil Builders L3 | Shree Vaishno Enterprises L6 | Vijaypower Generators Limited L1 | Electromech Engineers L7 | Vijay Construction Co L9 | DIVYA ELECTRIC CORPOORATION L4 | Truly Technos LLP L5 | Roy and Sons Infrastructures L2 | Chankaya Solutions L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for transporting of 125 KVA DG set with AMF panel from one location to MES store yard within 4km distance by disconnecting LT cables earthings etc as directed byEngineer-in charge. Note:- All T & P required for transportation shall be included in item rate quoted. | 3 | Each | 8,000 ₹24,000 | 10,000 ₹30,000 | 15,000 ₹45,000 | 9,000 ₹27,000 | 40,000 ₹1.2 L | 10,000 ₹30,000 | 10,000 ₹30,000 | 40,000 ₹1.2 L | 15,000 ₹45,000 | 15,551 ₹46,653 |
| 2.00 | Supply, installation, testing and commissioning of diesel engine driven generating set of 200 kVA (160 kW) (CPCB IV/or as per latest CPCB norms) rating, 415 Volts, 3 Phase, 4 Wire, 50 Hz, 1500 RPM, power factor 0.8 lag, complete with suitable base frame, anti-vibration mounts, microprocessor-based control panel, water cooled acoustic enclosure conforming to CPCB-IV+ norms, and necessary accessories for efficient and reliable operation. The DG set shall be designed to comply with ISO 8528, ISO 3046-1, ISO 15550 and relevant IEC/BS standards. All fabrication, power coating painting, and installation shall be carried out as per the manufacturer's recommendations and relevant Indian standards and as directed by Engineer-In-Charge.
(A) ENGINE:- The DG set shall be powered by 6-cylinder, 4-stroke, in-line, turbocharged diesel engine, developing suitable horsepower to deliver the rated output of 200 kVA at 1500 RPM under standard site conditions with a provision of 10% overload for one hour on 12 hrs running complete with standard accessories all as specified and directed for safe handling & operation silent features as under:-
(i) High Pressure Common Rail (HPCR) fuel injection system with Electronic Control Unit (ECU) for optimum performance and fuel economy. (ii) Full flow lubricating oil filter and lube oil cooling to maintain optimum temperature. (iii) Cast iron cylinder block with rugged body construction for durability. (iv) Lube oil capacity: approx. 24 litres. (v) Fuel consumption: in accordance with ISO 3046 with ± 5 % tolerance. (vi) Governor: Electronic type (ECU controlled). (vii) Cooling system: Radiator-cooled, designed for 50 °C ambient temperature, complete with fan, drive, and water pump. | 3 | Each | 30,80,000 ₹92.4 L | 23,00,000 ₹69 L | 24,40,000 ₹73.2 L | 22,60,000 ₹67.8 L | 23,50,000 ₹70.5 L | 29,25,000 ₹87.8 L | 25,00,000 ₹75 L | 26,64,270 ₹79.9 L | 23,00,000 ₹69 L | 29,51,111 ₹88.5 L |
| 2.01(viii) Starting system: 24 V DC electric starter motor with 2 x 12 V, 150 Ah batteries and charging alternator.(ix) Exhaust system: Turbocharged with shielded manifold and flexible outlet connection, max. back pressure <5 kPa. (x) Recommended lube oil: SAE 15W-40 CK4 grade. (xi) 40 Ltr of Urea to be provided for each DG set to top up tank. (xii) Control cable to be provided incl connection for auto operation of DG set. (xiii) Emergency stop push button. (B) ALTERNATOR:- The alternator shall be brushless, screen protected, self-excited, self-regulated type, directly coupled to the engine through a flexible coupling and mounted on a common base frame. Acceptable alternator makes: Stamford (SF S3L1D-H4) / equivalent of specified makes. The alternator shall conform to BS 5000, IEC 60034-1 standards and shall have the following features:- (i) Rated output: 200 kVA, 415 V, 50 Hz, 3-phase,0.8 pf, 1500 RPM. (ii) Insulation class: H; temperature rise H class. (iii) Voltage regulation: ± 1 % through AVR (Digital type DM740 / R180 / DSR). (iv) Overload capacity: 10% for 1 hour in 12 hours of operation. (v) Protection: IP 23 with sealed bearings. (vi) Winding pitch: 2/3 to ensure low harmonic distortion (< 5%). (vii) Cooling: Self-ventilated air cooled design. The control panel shall be microprocessor-based, built on a powder-coated sheet steel enclosure, wall/floor mounted on the DG set skid, and shall include a DEIF (Denmark) SGC 420 MK II controller suitable for AMF (Auto Mains Failure) operation. Controller Features:- (i) Back-lit graphical LCD display with multilingual menu. (ii) Local, remote, and automatic start/stop operation. (iii) Fully programmable via PC using USB/RS-485 communication. (iv) CAN bus interface for electronic engine communication. (v) Event log with last 100 events (date/time stamped). (vi) Configurable analogue/digital I/O and relay outputs. (vii) Supply voltage range: 8 to 32 V DC. (viii) Environmental protection: IP 65. (ix) Complies with IEC 60068 (vibration/shock) and IEC 61000-6-2/4 (EMI/EMC). Metering Parameters:- (i) Generator Voltage (Ph-Ph / Ph-N) (ii) Generator Current (R, Y, B) (iii) Frequency, kW, kVA, kVAr, Power Factor. (iv) Engine Speed (RPM) (v) Oil Pressure, Coolant Temperature, Battery Voltage, Running Hours, Fuel Level Protection Features: (i) High water temperature (ii) Low oil pressure (iii) Over speed (iv) Under/Over voltage (ANSI-27 / 59) (v) Under/Over frequency (ANSI-81 L / 81 H) (vi) Generator over current (ANSI-51) (vii) Phase reversal and unbalanced load (viii) Low fuel level / Engine fail to start 1.5 STANDARD SCOPE OF SUPPLY (ix) Diesel engine with radiator and cooling fan (x) Brushless alternator with AVR (xi) Microprocessor-based control panel (AMF ready) (xii) Base frame with anti-vibration mounts (xiii) Fuel water separator and flexible fuel lines (xiv) Exhaust outlet with flexible bellow and flanges Fuel tank: Capacity of fuel tank minimum 8 hrs running at full load. Note:- (i) Cost of M&L for making platform for DG set using block masonry 1:3:6 type C1 using 20mm graded aggregate with solid blocks & PCC (1:3:6) foundation concrete, 15mm thick plaster in CM 1:4 and two coats of cement based paint with allowable size for minimum height 45cm feet from GL and surface area not be less than 5.0m x 2.5m complete to the entire satisfaction of Engineer-In-Charge is deemed to be included in quoted rates. (ii) Excavation, earthwork, PCC & brick work etc complete to the entire satisfaction of Engr-In-Charge is included in the quoted rate. | |||||||||||||
| 3.00 | Supply, install, testing and commissioning of AMF Panel OUTDOOR TYPE suitable for 200 KVA DG set factory made out of CRCA Steel 3.15mm thick Sheet, floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof with front & rear opening rated voltage 440V, 3 phase, 4 wire 50 cycles having copper bus bar of 1.5 times the full load current of alternator duly colour coated with PVC suitable on load changeover for by pass arrangement of main supply & DG supply including two coats. The panel should be powder coated with minimum thickness of 50 microns, after elaborate pre-treatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :-
(i) Multifunctional meter digital (Amp + Volt + PF + Hz + KW + KWH) - 01 No. (ii) Alternator voltage monitor - 01 No (iii) Main voltage monitor - 01 No (iv) Ammeter DG digital - 01 No (v) Voltmeter DG digital - 01 No (vi) Main Power contactor - 4 pole of capacity 400 Amps - 01 No (vii) DG Power contactor - 4 pole of capacity 400 Amps - 01 No (viii) Indicator Lamp - 02 Nos (ix) MCB (For control ckt) -10 Nos | 3 | Each | 3,25,000 ₹9.8 L | 4,50,000 ₹13.5 L | 4,56,000 ₹13.7 L | 75,000 ₹2.3 L | 5,05,000 ₹15.2 L | 2,80,000 ₹8.4 L | 3,20,000 ₹9.6 L | 1,50,000 ₹4.5 L | 1,00,000 ₹3 L | 2,51,111 ₹7.5 L |
| 3.01(x) Auxiliary Contactor - 02 Nos (xi) Automatic battery charger 24 volt - 01 No (xii) Terminal O/L relay - 01 No (xiii) Terminals (for control cable) - 06 Nos (xiv) One set of copper bus bar of 600 Amps capacity (xv) Main MCCB -4 pole of capacity 400 Amps 36 KA - 01 No (xvi) DG MCCB - 4 pole of capacity 400 Amps 36 KA - 01 No (xvii) Outgoing MCCB - 4 pole of capacity 400 Amps 36 KA - 01 No. (xviii) Suitable size PVC copper cable for AMF connection as per site requirement with suitable size of PVC pipe bend, elbow etc as per site requirement - 01 No. Note: The required PCC foundation for AMF Panel is included in the rate. | |||||||||||||
| 4.00 | M & L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to and including GI strip 32 x 6mm as earthing lead by means of nut, bolts, check nuts and washers of galvanized iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following:- (a) Excavation and earth work for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 32 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing after completion of work will be done and resistance test cert has to be submitted by the contractor. (g) GI strip exceeding 7.5 RM will be measured under respective item. | 18 | Each | 7,000 ₹1.3 L | 6,000 ₹1.1 L | 7,000 ₹1.3 L | 6,000 ₹1.1 L | 10,000 ₹1.8 L | 8,000 ₹1.4 L | 7,000 ₹1.3 L | 5,500 ₹99,000 | 8,000 ₹1.4 L | 11,111 ₹2.0 L |
| 5.00 | S & F galvanized iron strip 32x6 mm with saddles and fixing screws etc for roof/down conductor above ground including joining with rivets, bolts, nuts, washers etc all as directed by EIC complete. | 40 | RUNNING METRE | 120 ₹4,800 | 175 ₹7,000 | 350 ₹14,000 | 198 ₹7,920 | 300 ₹12,000 | 450 ₹18,000 | 200 ₹8,000 | 90 ₹3,600 | 300 ₹12,000 | 351 ₹14,040 |
| 6.00 | Supply, laying and testing (in replacement) cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core including supply joining & testing complete all as specified. Note: Excavation and earth work cable protection and sand cushioning shall be measured and paid seperately under at item of this schedule. | 120 | RUNNING METRE | 1,700 ₹2.0 L | 2,050 ₹2.5 L | 2,145 ₹2.6 L | 2,100 ₹2.5 L | 2,710 ₹3.3 L | 2,400 ₹2.9 L | 2,300 ₹2.8 L | 2,020 ₹2.4 L | 1,970 ₹2.4 L | 1,451 ₹1.7 L |
| 7.00 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10 sqm on plan and not exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge. | 9.72 | CUBIC METRE | 200 ₹1,944 | 250 ₹2,430 | 250 ₹2,430 | 300 ₹2,916 | 300 ₹2,916 | 450 ₹4,374 | 300 ₹2,916 | 250 ₹2,430 | 300 ₹2,916 | 451 ₹4,383.72 |
| 8.00 | Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. | 6.39 | CUBIC METRE | 100 ₹639 | 50 ₹319.50 | 25 ₹159.75 | 21 ₹134.19 | 100 ₹639 | 100 ₹639 | 100 ₹639 | 100 ₹639 | 100 ₹639 | 151 ₹964.89 |
Updated dates
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
9 Jan 2026, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
SPECIAL REPAIR FOR REPLACEMENT OF BER DG SET AT AF STN BHUJ
2025_MES_743221_1
84259/E8
Open Tender
Electrical and Maintenance Works
180 days
BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) BHUJ
₹1.8 L
Yes
26 Feb 2026
5 Dec 2025
12 Jan 2026
5 Dec 2025
9 Jan 2026
26 Dec 2025
Supply, laying and testing (in replacement) cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10 sqm on plan and not exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all specified and directed.
M & L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. Note:- For measurement purpose punned thickness shall be considered.
M & L for unreinforced precast concrete cable covers CLASS LV type II, flat size 300 x 180 x 40 mm laid transverse to cable.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
TENDERDOCS84259.rar
Tender Documents • 10.09 MB
BOQ_832228.xls
BOQ • 1.34 MB
Download all tender documents and submit your bid