Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.1 L
EMD Value
₹4,265
Closing Date
9 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Upgradation of Sub Divisional Building RandB on NSC road near Pandach B.W.O Electric work
2025_PWDJK_299090_1
NIT No.240/2025-26 Dt/24/12/2025
Open Tender
Electrical Works
Percentage
Pandach
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹4,265
24 Dec 2025
24 Dec 2025
10 Jan 2026
24 Dec 2025
9 Jan 2026
24 Dec 2025
Part-A (Internal Electrification)
Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/ Finolex/ Anchor/ Salzer/ Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Wiring for Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Anchor/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/ Equivalent Make & shall be approved before execution of work.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Legrand(Myris)/ Anchor Rooma Plus/ Schneider(Zencelo)/ Equivalent Make & shall be approved before execution of work.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/ Finolex/ Anchor/ Salzer/Havells / eq. make to be approved by EIC)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output)
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex / eq. make to be approved by EIC)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer/Havells/ eq. Make) & shall be approved before execution of work.
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards.
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider / eq. make to be approved by EIC)
Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,Double Pole), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider / eq. make to be approved by EIC)
Supplying and Fixing of MCB 4-Way (4+12) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider / eq. make to be approved by EIC)
Supply/Installation/Testing and Commissioning of 12-15W + LED Surface/Recess Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 120 lm/W with Pressure Die cast Aluminium body & Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Wipro/Bajaj/Jaquar/LT/Crompton/Surya/Equivalent Make.
Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient / eq. make to be approved by EIC.
Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes.
Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/ Panasonic/ Anchor/ Schneider / eq. make to be approved by EIC
Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 230 volts DP MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel. The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices: 1. Normal Incoming: 100-125 Amp DP MCCB with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,200 Amp Bus bar Al Strips(P+N) = 1 Set,Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1No. 2. Generator Incomer: 63 Amp Single Phase Automatic Change over Switch of Havells/Legrand/Siemens/ABB/LK/Equivalent make = 1 No.
Supply/Installation/Testing & Commissioning of 1.5 TON inverter type split Air Conditioning system suitable for operation on AC supply single phase 220 V. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. (Hitach/L.G/Diakin/Equivalent Make) & stand ,Copper piping etc & all other allied accessories, installation charges,GST, income tax , carriage etc Complete job.The job includes 04-KVA Digital Stabilizer & CMC (reckoned from date of successful commissioning) for a period of Two years.
Supply and Fixing of Modular 32Amp industrial Socket outlet having fitted with 32 Amps DP MCB and Top with Modular Plate,Cover in front & suitable GI box etc for AC Points
Supply/Laying/Testing and Commissioning of 2- Core 25 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI / eq. make to be approved by EIC. The cable shall include end termination lugs with its crimping /taping.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.04 MB
BOQ_969929.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .