| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹5.4 L+₹7,735 (1.45%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹6.2 L+₹84,585 (15.8%)Rejected-Finance DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹6.5 L
EMD Value
₹13,000
Closing Date
13 Sept 2024, 6:00 pmClosed
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER TENDER DOCUMENTS AND BOQ
2024_MES_667666_1
AGE(I)/SL/8609
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) SURYALANKA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) SURYALANKA
₹13,000
Yes
20 Sept 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
8 Aug 2024
25 Jul 2024 - 3 Aug 2024
Amount
M&L for servicing of DG sets at site including provision and replacement of old fuel filters, oil filters, air filters, air filter element, changing of lubrication oil suitable for up to 100 KVA DG set, cleaning of fuel lines, checking leakage if any, repair the leakage by welding, brazing and replacement of rubber gasket etc complete all as specified and directed for following capacity of DG sets:- Note : The quoted rate is inclusive of the items / material as mentioned above.
62.5 KVA / 50 KVA
45 KVA/40 KVA
30 KVA/25KVA/21.5 KVA
12.5 KVA/10 KVA
M&L for Disconnecting the electrical connection of DG sets of capacity 100/82.5/62.5 KVA at site by opening the enclosures, alternator separately and opening the engine to access the repair/unserviceable parts and transport the same to workshop for repair/replacement of unserviceable/worn-out parts and assembling the same including re-connection of electrical cable, enclosures, panel and testing at site by running continuously for 6 hours at connected load complete all as specified and directed . Note : 1. The quoted rate shall includes the cost of replacement of minor rusted spares like nuts & bolts, washers, Screw hexagon head cap, Seal rectangular ring, hose clamp, various types of hoses & cleaning the engine parts with diesel etc as required for running the Engine smooth (except spares mentioned below).
S&F in repair water pump suitable for DG Set of 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair turbo repair kit suitable for DG Set of 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair piston ring for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair connecting rod for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair V belt for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair gasket gear cover for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair valve intake for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair valve Exhaust for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair cooling system of engine for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair gasket set upper for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair gasket set lower for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair Lubrication oil Pump for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair Piston kit for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in replacement of vibration damper set for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in repair turbo charger for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
S&F in replacement of copper cable for battery for DG set of capacity 100/82.5/62.5 KVA complete all as specified and directed
M&L for Disconnect all electrical connection of DG sets of capacity 50 KVA to 30 KVA at site by opening the enclosures, alternator separately and opening the engine to access the repair/unserviceable parts and transport the same to workshop for repair/replacement of unserviceable/worn-out parts and assembling the same including re-connection of electrical cable, enclosures panel and testing at site by running continuously 6 hours at connected load complete all as specified and directed . Note :- 1. The quoted rate shall includes the cost of replacement of minor rusted spares like nuts & bolts, washers, Screw hexagon head cap, Seal rectangular ring, hose clamp, various types of hoses & cleaning the engine parts with diesel etc as required for running the Engine smooth (except spares mentioned below).
S&F in repair of FIP suitable for DG Set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair of cylinder liner suitable for DG Set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair piston pin for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair piston ring for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair piston Assembly for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair cylinder head bolt for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair inlet valve seat insert for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair exhaust valve seat insert for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair Cylinder head reconditioning kit for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair valve tappet for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair valve rocker Assy for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair rocker cover for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair rocker lever assembly for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair set of joints kit for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair gasket set upper for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair gasket set lower for DG set of capacity 50 KVA to 30 KVA complete all as specified and directed
S&F in repair the crank shaft by brazing the top portion to make to adjust to the engine RPM capacity 50 KVA to 30 KVA complete all as per manufacturer's instructions and as directed.
S&F in repair all high pressure fuel lines with end coupler complete with new high pressure line fixed properly (without any leakage) to the engine of DG Set of capacity 50 KVA to 30 KVA complete all as per existing size and as directed.
S&F in repair radiator fan belt of suitable size complete all as per manufacturer's instructions of capacity 50 KVA to 30 KVA complete all as specified and as directed..
M&L for cleaning and de-scaling of radiator assembly of DG Set capacity 50 KVA to 30 KVA by using suitable chemical and blower fan ,injecting water with high pressure in water tubing's so as to remove all dirts in the fins, taking down the copper bottom portion of tank for welding / brazing and refit the same after replacing the unserviceable and damaged fins tank cap rubber bush and refix the same at the engine of DG sets and testing to check the leakage by using high pressure water complete all as per specified and as directed..
S&F Fly wheel in replacement suitable in size of DG Set of capacity 50 KVA to 30 KVA as per site requirement complete all as specified and as directed by Engr in Charge.
S&F in replacement water hose pipe of suitable size and length suitable of the DG Set of capacity 50 KVA to 30 KVA complete all as specified and as directed.
M&L for Opening of DG set alternator by removing the canopy panel carefully required to remove the alternator of capacity 82.5/100 KVA/62.5 KVA and taking out unserviceable alternator lifting, loading and transportation of Alternator to the work shop for removing worn-out stator winding, cleaning of stator slots, rewinding/lathe work by using suitable copper winding material and insulation, varnish as existing, etc and taking back to MES store yard /installation after repair work, re-assembling of DG sets including testing for 6 hours continuously with connected load complete all as specified and directed . Note:- the quoted rate shall include the cost of minor spares required for healthy operation of alternator like screws, nuts & bolts etc except spares covered below
All as per item No 04 above but Alternator of DG Set of capacity 50 KVA to 30 KVA complete all as specified and directed
Supply and fix in replacement rectifier /Diode plate of DG Set of capacity 100 KVA to 30 KVA all as per existing complete all as specified and directed.
S&F carbon brush in replacement of DG set capacity 100 KVA to 30 KVA all as per manufacturer's instructions and complete all as specified and directed.
S&F slip rings in replacement all capacity of DG set of capacity 100 KVA to 30 KVA as per manufacturer's instructions and complete all as specified and directed.
S& F of bearing in replacement suitable for DG set of capacity 100 KVA to 30 KVA as per existing complete all as specified and directed
Disconnect the self starter from the engine ,loading and shifting motor to work shop for repair to starter by change of carbon bushes , solenoid switch and change of slip rings etc, taking back to MES store and connected to engine of capacity 100 KVA to 30 KVA including ,commissioning and testing complete all as directed.
S & F in replacement of Generator Control Module Panel, LCD display,, Fault Check, self starting , Gen set controller presentable with Monitoring and protections functions for 3 Phase Mains Detection for DG Set of capacity 25 KVA as per existing in site complete all as specified and as directed.
S&F in replacement of ignition switch assembly complete with nuts and bolts on DG set including all electrical connection by using suitable gauge of copper wire and testing for DG set of capacity up to 100 KVA complete all as specified and directed.
S&F in replacement of AVR of Suitable capacity applicable for DG Set of capacity 100 KVA to 30KVA DG Set complete all as specified and as directed.
S&F in replacement of stop solenoid switch of Suitable capacity applicable for DG Set of capacity 100KVA to 30 KV A complete all as specified and as directed.
Supply and fill coolant of standard specification for top up in radiator of Diesel Engine of DG Sets of capacity 100 KVA to 10 KVA of any type all complete all as specified and directed.
Opening of the AMF panel by unscrewing screws, nuts bolts etc after removing all connection to DG sets and LT panel and reassemble the AMF panel after repair / replacement of worn out parts including fixing only the serviceable parts/ new parts/wiring works complete including all connection, commissioning and testing complete all as specified and directed. Note:-Supply only spare parts shall be measured and paid separately vide item No.13.00
Supply only the following spare parts of AMF panel as per existing capacity and make complete all as specified and directed:-
Control relay
OD DC timer
Line voltage monitor
Announciator
EF relay
Power contactor heavy duty 4 pole of rating upto 160 Amps as per existing in site complete all as specified and as directed..
Current Transformer
M & L for repair of DG set doors (04 Nos) by replacing of hinges, locking system, welding of broken door/cover parts etc complete all as specified and directed
Supply and fixing in replacement of maintenance free battery 130 AH, 12V with indication of battery status on top suitable for upto 100 KVA DG set including necessary nuts & bolts, initial charge, two nos brass suitable terminals for connection etc complete all as specified and directed
Supply and fixing in replacement of maintenance free battery 90 AH, 12V with indication of battery status on top suitable for upto 30 KVA DG set including necessary nuts & bolts, initial charge, two nos brass suitable terminals for connection etc complete all as specified and directed
Supply and fixing in replacement of lubrication oil pressure sensor of existing make suitable for up to 100 KVA DG set complete all as specified and directed
PAVANI INFRAS (BID ID -3090661)
BEST ENGINEERING (BID ID -3090569)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .