Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC NANDNI VIHAR ADHOIWALA DEHRADUN | ₹4.9 Cr Quoted ₹6.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹6.9 Cr+₹77.3 L (12.6%)Rejected-Finance VILLAGE KAIRWAN KARANPUR PO RAJPUR DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | ₹6.9 Cr+₹77.3 L (12.6%) | L2 | Rejected-Finance Second Lowest |
Tender Value
₹4.7 Cr
EMD Value
₹9.4 L
Closing Date
7 Feb 2023, 5:00 pmClosed
SUPERINTENDING ENGINEER
OFFICE OF THE SUPERINTENDING ENGINEER CONSTRUCTION CIRCLE UTTARAKHAND PEYAJAL NIGAM GOPESHWAR
Peeda Solar Pumping Bamsu Solar and GwarThapli Water Supply Scheme of Block Augustmuni
2023_MDPEY_54524_1
81/Lekha-05/35 Dated 23.01.2023
Open Tender
Civil Works
Item Rate
365 days
Block Augustmuni
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Executive Engineer Construction Division UKPJN
₹9.4 L
Rudraprayag
15 Sept 2023
1 Feb 2023
9 Feb 2023
1 Feb 2023
7 Feb 2023
1 Feb 2023
1 Feb 2023
Amount
Peeda Solar Pumping W/S Scheme of Block Augustmuni SOURCE WORKS
Construction of Intake chamber(1.0mx1.0mx1.5m) including Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge
Construction of RCC Gadhera tapping arrangement i.e., 4m wide Cross wall Boulder Filled Gallery with Intake chamber to fulfill the requierment of water demand including Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge.
Construction of R.C.C. Cross wall Gadhera tapping arrangement per running meter length excess over 4m gadhera including supply of all materials,labour, T&P etc. complete.
Survey, design and Construction of Roughening Filter with filling of supporting & filter media (submitted design should be as per type design subject to site condition) including all materials, cartage labour, T&P etc. required for proper completion of work
Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assuming that 90% pipe line is laid in trenches, it is estimated that 75% excavation will be in soil mixed with shingle, bajari and boulders and rest 25% will be in medium rock
Soil mixed with boulder (SMB)
Medium Rock (MR)
Supply, carting , laying true to aligment and gradient, jointing and fixing of following GI (M) pipe lines including all specials fittings, white lead, hemp and other appurtenant works etc. making necessary connections with existing laid pipe line including connecting with existing Private & Othe house hold Tap Connections with control plate/ferrule devices etc complete and make proper functioning, confirming to IS:1239 at site of works. On completion of work the laid length of pipe will be deemed eligible for supply. The respective amount for quantity of surplus supply of pipes (which remained unlaid or unutilized) will be deducted from final bill and surplus quantity of pipes will be the property of contractor.
15 mm dia - GI (M)
20 mm dia - GI (M)
25 mm dia - GI (M)
32 mm dia - GI (M)
40 mm dia - GI (M)
50 mm dia - GI (M)
Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assuming that 90% pipe line is laid in trenches, it is estimated that 75% excavation will be in soil mixed with shingle, bajari and boulders and rest 25% will be in medium rock
Soil mixed with boulder (SMB)
Medium Rock (MR)
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of MSERW, Jointing by electric welding process with proper grade of eletrodes suitable for jointing of water supply pipe lines (Ador, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete.
From MPS to IPS Ist. MSERW Pipe 65 mm Dia 4.00 mm Thickness
Dismentling and relaying of following sizes of G.I. Pipes Medium quality confirming to IS:1239 at site of works including all labour T&P etc. complete for proper completion of work & also for making FHTC laid from existing newly laid pipe lines under scheme as per direction &instruction of given by Engineer -In-Charge.
15mm dia
20mm dia
25mm dia
32mm dia
Supply and fixing of Wheel Valve/ Gate Valve of the following sizes including cartage of materials, labour, T&P etc. complete
20 mm dia
25mm dia
32mm dia
40 mm dia
50mm dia
Supply & fixing of following sizes of valves including carting the same up to side of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect
Gate Valve/Reflux Valve 65 mm dia
C.I. Air valve 65 mm
Supply of all materials, labour, T & P etc. and Construction of size Sluice Valve / Reflux Valve / Scour Valve Chamber as per type design complete(0.90x0.90x1.0)
Supply of all materials, labour, T & P etc. and Construction of size Air Valve Chamber as per type design complete(0.90x0.90x1.0)
Supply of all materials, labour, T & P etc. and Construction of R.C.C Anchor Block as per type design complete
Making 2 M wide Briddle path for rising main including hill side cutting and coolie walling of all materials, labour, T & P etc.
Painting of MSERW/API Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) (Dia of pipe in mm)
65 mm dia
Supply Cartage and fixing of Sluice Valve/Air Valve of the following sizes including cartage of materials, labour, T&P etc. complete
20mm dia (CI Air Valve)
Constructing Wheel Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement.
Constructing masonry Air Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement.
Construction of following capacity RCC semi sunk reservoir, including testing and commissioning for water tightness, with supply of all materials Labour, T&P etc and construction of RCC CWR of following capacities (in kiloliters) with M.S. ladder outside & inside of the tank, M.S. M.H. Cover with locking arrangement, supply and fixing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex)/enamel paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8 MT/M2
Supply cartage and fixing of Bucket type chlorinator of 25 Liter capacity at top of service raservoirs.
Supply, Cartage of all materials, labours, T&P, etc complete making of ferrule connection to provide FHTC to the consumers from existing/Newly laid pipe lines under scheme as per instruction given by Engineer-In-charge.
Supply of all materials,labour,T&P etc and construction of Break pressure tank (BPT)
Concrete with 2 Cm gauge stone ballast, local sand and cement in proportion of 1:2:4 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work.
Concrete with 4 Cm gauge stone ballast, local sand and cement in proportion of 1:4:8 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work.
Miscellaneous Work
Construction of 1.5 m high Boundary Wall in brick masonry including supply of all materials, labour, T&P etc. complete
Installation of Barbed Wire Fencing through angle iron posts around the water works site
Installation of M.S. Iron Gate with Pillars of following sizes complete (3.6 m wide)
Construction of Pannel Room (1.5 x1.5x2.0)sizes complete
R.R. Stone masonary with 1:6 cement and sand mortar including cartage and supply of all materials,labours,T&P etc. complete for proper completion of work.
R.R.Stone masonry laid in dry including cartage and supply of all materials,labours,T&P etc. required for proper completion of work.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Supply & installation of solar Submersible Pump, Control Panel, Solar Panels, wiring, automation including supply of all materials,labour, T&P etc complete as per latest specification and direction as per engineer in charge.
MPS to IPS Ist ( 200 LPM discharge and 295 m head) for Peeda solar pumping Scheme
IPS 1st to IPS IInd ( 200 LPM discharge and 218 m head) for Peeda solar pumping Scheme
IPS IInd to Top CWR ( 200 LPM discharge and 215 m head) for Peeda solar pumping Scheme
Solar panel 335 WP x 336 = 112560 watt with GI structure for Peeda solar pumping Scheme
Control Panel/VFD panel hybrid controller (solar+Grid)
Complete Wiring of all the above system
Earthing of above system
Installation of all the above system
Construction of of electrical Pole and Grouting etc including supply of all materials,labour, T&P etc. complete.
Bamsu Solar Pumping W/S Scheme of Block Augustmuni
SOURCE WORKS
Construction of Intake chamber(1.0mx1.0mx1.5m) including Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge
Construction of R.C.C. Cross wall Gadhera tapping arrangement per running meter length excess over 4m gadhera including supply of all materials,labour, T&P etc. complete.
Survey, design and Construction of Roughening Filter with filling of supporting & filter media (submitted design should be as per type design subject to site condition) including all materials, cartage labour, T&P etc. required for proper completion of work
Supply, carting , laying true to aligment and gradient, jointing and fixing of following GI (M) pipe lines including all specials fittings, white lead, hemp and other appurtenant works etc. making necessary connections with existing laid pipe line including connecting with existing Private & Othe house hold Tap Connections with control plate/ferrule devices etc complete and make proper functioning, confirming to IS:1239 at site of works. On completion of work the laid length of pipe will be deemed eligible for supply. The respective amount for quantity of surplus supply of pipes (which remained unlaid or unutilized) will be deducted from final bill and surplus quantity of pipes will be the property of contractor.
15 mm dia - GI (M)
20 mm dia - GI (M)
25 mm dia - GI (M)
32 mm dia - GI (M)
40 mm dia - GI (M)
50 mm dia - GI (M)
65 mm dia - GI (M)
Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assuming that 90% pipe line is laid in trenches, it is estimated that 75% excavation will be in soil mixed with shingle, bajari and boulders and rest 25% will be in medium rock
Soil mixed with boulder (SMB)
Medium Rock (MR)
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of MSERW, Jointing by electric welding process with proper grade of eletrodes suitable for jointing of water supply pipe lines (Ador, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete.
From MPS to Top Cwr. MS ERW Pipe 32 mm Dia 2.6 mm Thickness
Dismentling and relaying of following sizes of G.I. Pipes Medium quality confirming to IS:1239 at site of works including all labour T&P etc. complete for proper completion of work & also for making FHTC laid from existing newly laid pipe lines under scheme as per direction &instruction of given by Engineer -In-Charge.
15mm dia
20mm dia
25mm dia
32mm dia
40mm dia
50mm dia
65mm dia
Supply and fixing of Wheel Valve/ Gate Valve of the following sizes including cartage of materials, labour, T&P etc. complete
20 mm dia
25mm dia
32mm dia
40 mm dia
50mm dia
Supply & fixing of following sizes of valves including carting the same up to side of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect
Gate Valve/Reflux Valve 32 mm dia
C.I. Air valve 32 mm
Supply of all materials, labour, T & P etc. and Construction of size Sluice Valve / Reflux Valve / Scour Valve Chamber as per type design complete(0.90x0.90x1.0)
Supply of all materials, labour, T & P etc. and Construction of size Air Valve Chamber as per type design complete(0.90x0.90x1.0)
Supply of all materials, labour, T & P etc. and Construction of R.C.C Anchor Block as per type design complete
Making 2 M wide Briddle path for rising main including hill side cutting and coolie walling of all materials, labour, T & P etc.
Painting of MSERW/API Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) (Dia of pipe in mm)
32 mm dia
Supply Cartage and fixing of Sluice Valve/Air Valve of the following sizes including cartage of materials, labour, T&P etc. complete
20mm dia (CI Air Valve)
Constructing Wheel Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement.
Constructing masonry Air Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement.
Construction of following capacity RCC semi sunk reservoir, including testing and commissioning for water tightness, with supply of all materials Labour, T&P etc and construction of RCC CWR of following capacities (in kiloliters) with M.S. ladder outside & inside of the tank, M.S. M.H. Cover with locking arrangement, supply and fixing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex)/enamel paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8 MT/M2
Supply cartage and fixing of Bucket type chlorinator of 25 Liter capacity at top of service raservoirs.
Supply, Cartage of all materials, labours, T&P, etc complete making of ferrule connection to provide FHTC to the consumers from existing/Newly laid pipe lines under scheme as per instruction given by Engineer-In-charge.
Supply of all materials,labour,T&P etc and construction of Break pressure tank (BPT)
Concrete with 2 Cm gauge stone ballast, local sand and cement in proportion of 1:2:4 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work.
Concrete with 4 Cm gauge stone ballast, local sand and cement in proportion of 1:4:8 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work.
Miscellaneous Work
Construction of 1.5 m high Boundary Wall in brick masonry including supply of all materials, labour, T&P etc. complete
Installation of Barbed Wire Fencing through angle iron posts around the water works site
Installation of M.S. Iron Gate with Pillars of following sizes complete (3.6 m wide)
Construction of Pannel Room (1.5 x1.5x2.0)sizes complete
Excavation for foundation in Soil mixed with boulders
R.R. Stone masonary with 1:6 cement and sand mortar including cartage and supply of all materials,labours,T&P etc. complete for proper completion of work.
R.R.Stone masonry laid in dry including cartage and supply of all materials,labours,T&P etc. required for proper completion of work.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Supply & installation of solar Submersible Pump, Control Panel, Solar Panels, wiring, automation including supply of all materials,labour, T&P etc complete as per latest specification and direction as per engineer in charge.
MPS to Top CWR ( 50 LPM discharge and 195 m head) For Bamsu solar pumping Scheme
Solar panel 335 WP x 39 = 13065 watt with GI structure For Bamsu solar pumping Scheme
Control Panel/VFD panel hybrid controller (solar+Grid)
Complete Wiring of all the above system
Earthing of above system
Installation of all the above system
Construction of of electrical Pole and Grouting etc including supply of all materials,labour, T&P etc. complete.
Gwar Thapli W/S Scheme of Block Augustmuni
SOURCE WORKS
Construction of Intake chamber(1.0mx1.0mx1.5m) including Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge
Construction of RCC Gadhera tapping arrangement i.e., 4m wide Cross wall Boulder Filled Gallery with Intake chamber to fulfill the requierment of water demand including Supply of all materials, labour,carting of material T&P etc complete as per direction of Engineer in charge.
Construction of R.C.C. Cross wall Gadhera tapping arrangement per running meter length excess over 4m gadhera including supply of all materials,labour, T&P etc. complete.
Survey, design and Construction of Roughening Filter with filling of supporting & filter media (submitted design should be as per type design subject to site condition) including all materials, cartage labour, T&P etc. required for proper completion of work
Supply, carting , laying true to aligment and gradient, jointing and fixing of following GI (M) pipe lines including all specials fittings, white lead, hemp and other appurtenant works etc. making necessary connections with existing laid pipe line including connecting with existing Private & Othe house hold Tap Connections with control plate/ferrule devices etc complete and make proper functioning, confirming to IS:1239 at site of works. On completion of work the laid length of pipe will be deemed eligible for supply. The respective amount for quantity of surplus supply of pipes (which remained unlaid or unutilized) will be deducted from final bill and surplus quantity of pipes will be the property of contractor.
15 mm dia - GI (M)
20 mm dia - GI (M)
25 mm dia - GI (M)
32 mm dia - GI (M)
40 mm dia - GI (M)
Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete assuming that 90% pipe line is laid in trenches, it is estimated that 75% excavation will be in soil mixed with shingle, bajari and boulders and rest 25% will be in medium rock
Soil mixed with boulder (SMB)
Medium Rock (MR)
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of MSERW, Jointing by electric welding process with proper grade of eletrodes suitable for jointing of water supply pipe lines (Ador, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete.
Dismentling and relaying of following sizes of G.I. Pipes Medium quality confirming to IS:1239 at site of works including all labour T&P etc. complete for proper completion of work & also for making FHTC laid from existing newly laid pipe lines under scheme as per direction &instruction of given by Engineer -In-Charge.
15mm dia
20mm dia
25mm dia
32mm dia
Supply and fixing of Wheel Valve/ Gate Valve of the following sizes including cartage of materials, labour, T&P etc. complete
20 mm dia
25mm dia
32mm dia
Supply & fixing of following sizes of valves including carting the same up to side of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect
CI Air Valve 20 mm dia
Constructing Wheel Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement.
Constructing masonry Air Valve Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse) including supply, cartage of all material, labour, T&P etc complete for Sluice Valve/Air Valve with C.I. surface box 100 mm. as per standard design. with locking arrangement.
Construction of following capacity RCC semi sunk reservoir, including testing and commissioning for water tightness, with supply of all materials Labour, T&P etc and construction of RCC CWR of following capacities (in kiloliters) with M.S. ladder outside & inside of the tank, M.S. M.H. Cover with locking arrangement, supply and fixing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex)/enamel paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8 MT/M2
Supply cartage and fixing of Bucket type chlorinator of 25 Liter capacity at top of service raservoirs.
Supply, Cartage of all materials, labours, T&P, etc complete making of ferrule connection to provide FHTC to the consumers from existing/Newly laid pipe lines under scheme as per instruction given by Engineer-In-charge.
Supply of all materials,labour,T&P etc and construction of Break pressure tank (BPT)
Concrete with 2 Cm gauge stone ballast, local sand and cement in proportion of 1:2:4 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work.
Concrete with 4 Cm gauge stone ballast, local sand and cement in proportion of 1:4:8 in foundation and floors including supply of all materials, labour and T&P etc.required for proper completion of work.
SAKLA NAND LAKHERA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .