Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹90.8 LAccepted-AOC | 1 | Accepted-AOC accept | |
| 2 | 2₹1.0 Cr+₹11.2 L (12.3%)Rejected-AOC | 2 | Rejected-AOC reject | |
| 3 | Rejected-Technical | - | Rejected-Technical reject |
Tender Value
Refer Docs
Closing Date
7 Feb 2022, 5:00 pmClosed
Executive Engineer MD UJS
Office Of Executive Engineer, Maintenance Division, Uttrakhand Jal Sansthan Lane No-1, Tarun Vihar, Mothrowala Road, Dehradun-248001
Construction of Hartad Santad Supply Scheme Including Supply, Installation, testing and commissioning of Gravity Main and Distribution System, Construction of Clear Water Reservior etc complete
2022_UKJS_41441_11
3807/E-Tender Notice dt 24.12.2021
Open Tender
Civil Works - Water Works
Item Rate
365 days
Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,720
Executive Engineer Maint Div UJS
Exempted
Dehradun
14 Jul 2023
5 Jan 2022
8 Feb 2022
5 Jan 2022
7 Feb 2022
13 Jan 2022
10 Jan 2022
Construction of Hartad Santad Supply Scheme Including Supply, Installation, testing & commissioning of Gravity Main & Distribution System, Construction of Clear Water Reservior etc complete under Jal Jeevan Mission Program
Source (Intake Chamber)- Construction of Intake Chamber (1.5M x 1.5M x 1.0M) including all labour & Materials , Machinery etc Complete. as per Attached Drawing and unit Estimate.
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royalties etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specification (pipe line and c.w.r)
IOT based monitoring system including all pressure sensor, chlorine sensor with all including accessories.
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royalties etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD (main pipeline CWR protection) Specification
construction of B.P.T
Excavation in Pipe Line Trenches (Over All Quantity i.e. Ordinary Soil and soil mixed with single boulders)-Laying of pipe line.(Open Laying without Excavation 20% of Total Quantity)-65 MM DIA
50 MM DIA
25 MM DIA
32 MM DIA
Excavation in Pipe Line Trenches-Excavation in ordinary soil (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling watering and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth (60 % of Total Quantity)
Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches.(20% of Total Quantity)
G.I. pipe conforiming to IS:1239(PART-1) -Proving of all materials, carting from site store to site of work, Laying & Jointing of full length GI screwed Pipes (including supply of all jointing materials like specials, white lead,hemp and oil etc)in trenches with its cutting ,threading and testing of pipeline etc complete.-GI pipe Medium Duty,( Class "B")-65 MM DIA
50 MM DIA
25 MM DIA
32 MM DIA
Supply of G.M. Gate Valve Class-I with hand wheel ISI marked conforming to IS: 778/1984 (Reaffirmed 2000) for water works purpose.-Brass/G.M. Valve-Pressure PN 1.0-65 MM DIA
Installation, testing and commissioning of G.M. Gate Valves as per engineering norms anywhere in uttarakhand.-Brass/G.M. Valve-65 MM DIA
supply of air valve-GI air valve 20 mm dia
installation testing of air valve-G.I air valve 50 mm dia
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For different types of valves.
Supply of all materials, labour, T&P etc and construction of R.C.C. CWR of following capacities ( in kiloliters ) with M.S. ladder outside & inside of the tank, M.S. M.H. cover with locking arrangement, supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT/M2-50 KL CWR/GLSR
15 KL CWR/GSLR
Supply of FRP coated MS Bucket type Chlorinator of 25 litres capacity with chlorination of 25 lit capacity with chlrination arrangement .
For Pipe Laying-Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately (Considering 30% Length)
For Pipe Laying-Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383,maximum size ofcoarse aggregate notexceeding 25 mm,mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
EARTHWORK FOR CUTTING ,FILLING AND DISPOSAL OF SURPLUS -Excavation in Pipe Line Trenches open laying (Over All Quantity i.e. Ordinary Soil and soil mixed with single boulders)(20%)-15mm dia GI Pipe (Medium Duty, Class B)
20mm dia GI Pipe (Medium Duty, Class B)
25 mm dia g.i pipe
32 mm dia g.i pipe
40 mm dia
50 mm dia
65 mm dia
Excavation in Pipe Line Trenches-Excavation in ordinary soil (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling waterring and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth (60% of Total Quantity)
Excavation in soil mixed (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling waterring and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth (20% of Total Quantity)
Providing and laying of pipes-GI pipe for water supply conforiming to IS:1239.1.2004 Proving of all materials, carting from site store to site of work, Laying & Jointing of GI screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc )in trenches with its cutting threading an testing of pipe line etc complete-15mm dia GI Pipe (Medium Duty, Class B)
20mm dia GI Pipe (Medium Duty, Class B)
25 mm dia GI Pipe (Medium Duty, Class B)
32 mm dia g.i pipe
40 mm dia g.i pipe
50mm dia GI Pipe (Medium Duty, Class B)
65mm dia GI Pipe (Medium Duty, Class B)
Valves &Chamber (DISTRIBUTION MAIN)-Supply of G.M Gate Valve Class-I with hand wheel ISI marked conforming to IS: 778/1984 (Reaffirmed 2000) for water work purpose-Brass/GM Valve-Pressure PN1.0-32 mm dia g.i pipe
50 mm dia
Installation testing of gate valve-32 mm dia g.i pipe
50 mm dia
Construction masonry Chamber 90x90x100 cm inside in brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve with C.I surface box 100mm top diameter , 160 mm bottom diameter amd 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), i/c necessary excavation ,foundation concrete 1:5:10( 1 cement :5 fine sand :10 graded stone aggregate 40mm nominal size) and insided plastering with cement mortor 1:3 (1 cement :3 coarse sand ) 12mm thick , finished with a floating coat of neat cement complete as per standard design : with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 for different types of valves
House Hold connections-supply of all labour , marerial required for restoring of existing house connetion witch might be damage during excavation and also shifting all existing 15 mm size water connection
Providing and making house service connections from water supply distribution GI pipe line upto watermeter chamber inside the property using GI pipe including supply and fixing of electrofussion saddle , brass ferules elbow, ball valve etc complete with earthwork , road cutting with restoration works .
O& M for trial and testing of pipe
Testing of pipe
Cartage from market to store
BHARAT SINGH PANWAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .