| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.5 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹33.9 L+₹2.0 L (6.27%)Rejected-AOC | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹35.2 L+₹3.3 L (10.3%)Rejected-AOC HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-3 | Rejected-AOC Rejected | |
| 4 | L-4₹36.0 L+₹4.1 L (12.7%)Rejected-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | L-4 | Rejected-AOC Rejected | |
| 5 | L-5₹37.2 L+₹5.2 L (16.3%)Rejected-AOC | L-5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
17 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NALIYA No 1
GE Air Force Station Naliya No 01
Provn of power infra for installation for SDR sets and certain repair work at KV school under GE AF Naliya
2022_MES_571795_1
8839/E8
Open Tender
Civil Works
Item Rate
270 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF NALIYA No 1
₹70,000
Yes
3 Jul 2023
28 Dec 2022
19 Jan 2023
28 Dec 2022
17 Jan 2023
11 Jan 2023
28 Dec 2022 - 3 Jan 2023
Amount
Dismantling of bricks tiles/PCC or terracing tiles aof any thickness single layer on roofs laid bedded and pointed in any mortar and removing the debris outside the defence land complete all as specified.
Taking down existing bitumen felt including cement mortar bedding including padding cleaning the surface and removal outside the MOD land complete all as specified and directed.
M&L for providing cement concrete (1:2:4) type B-0 (using 12.50mm graded stone aggregate) laid on roof in adequate slope complete all as specified and directed.
M&L for rendering 10mm thick cement plaster in cement mortar 1:3 on roof slab/canopies/chajjas with water proofing compound @3% by weight of cement or as per manufacture's instruction and make surface to receive water proofing treatment, finished even and smooth without using extra cement complete all as specified and directed. (Note:- water proofing compound will be measured and paid for separetaly as under relevant item)
Supply only integral water proofing compound all as specified.
M&L for preparing, clean and dried plastered roof surfaces and applying APP modified water proofing membrane with non woven polyster reinforcement/mat not less than 3mm thick having weight not less than 3.5 kg/sqm over a coat of bituminous filler/primer @ 250gm/sqm conforming to IS 3384-1986 through approved applicator and applying bitumenious aluminium paint @ 100gm/sqm on top of APP membrane all as per manufacture's instructions complete all as specified and directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Taking up or down 40 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S & F for 40 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and directed
Refixing old 40 mm bore steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) complete all as specified and directed.
M&L for cutting out cracks to 'V' section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for rendering 15mm thick cement plaster in two layers with 10mm thick in cement mortar (1:6) as 1st coat and 5mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement as 2nd coat on brick or concrete wall surfaces, finished even and smooth without extra cement including taking down of cement plaster from surfaces of wall of any description including raking out joints, hacking out for key, scrubbing down with water etc complete all as specified and directed. Note:- WPC shall be measured and paid for separately.
M&L for preparing new plastered surfaces of walls and applying two coats of acrylic based paint (Exterior emulsion paint) over a coat of primer complete all as specified and directed.
S&F for 25mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F for rotational moulded polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position of 1000 ltrs capacity fixed with PVC tank nipples, complete all as specified.
S & F 40 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply, install, testing and commissioning of Diesel engine driven generating set 30 KVA, 3 phase 4 wire, 415 volts,1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling installation & shifting of the equipment at site. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-II) latest norms/regulation with fuel tank, battery and standard accessories and PCC foundation for (acoustic enclosure also 30 CM above ground level) as recommended by manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by manufacturer all as specified and as directed with the following specifications:
(A) ENGINE :- Water cooled diesel engine of suitable capacity to match the 30 KVA alternator under NTP conditions with provision of 10% over load for 1 hour in every 12 hours running confirming to BS-5514. The engine shall consist of following :- (i) Fly wheel (ii)Close coupling (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (iv) Radiator with guard and water pump engine mounted (v) Battery charging alternator (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (FIP) (viii) Radiator fan(blower type) with guard (ix) Precision governor (mechanical type)
(x) Fuel filter (xi) Lubricating oil filters (mounted) (xii) 12 V self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resister /scale inhabitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump ( gear type) (xviii) Exhaust pipeing as per manufecturer design
(B) Control Panel : The Control Panel is manufactured with 14/16 guage CRCA sheet and is powder coated for a weather - proof and long lasting finish. The Control Panel consists of the following parts: (i) S0500 Controller (ii) Aluminium Bas Bars with suitable capacity with in/ outgoing terminals (iii) Indicating Lamps for'Load On"and 'Set Running' (iv) MCCB of suitable rating with overload and short circuit protections.
vii) Engine Control :- (a) Powerstart operates on 12 VDC batteries. (b) Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also make up the control system from sleep mode. (c) Engine Starting - The control system supports automatic engine starting, primary and backup start disconnects are achived by battery charging alternator feedback or main alternator output frequency. (d) Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. (e) Sleep mode increase battery life. Configurable current setting from low to minimize current draw when genset is not working. (viii) Engine protective Functions includes. (a) Configurable alarm output. (b) Emergency stop: Annunciated whenever an emergency stop signal is recieved by the control. (c) Low lube oil pressure warning and shutdown (d) High engine water tempreature warning / shutdown. (e) Low coolant temp warning. (f) Sensor failure indication. (g) Low and high battery voltage warning. (h) Weak battery warning. (j) Fail to start shut down. (k) Cranking lockout: Control will not allow the starter to engage or to crank the running engine. (l) Cyclic cranking: Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods. (ix) Alternator Protective functions includes (a) High and low AC voltage shut down (b) Under and over frequency shutdown / warning (c) Loss of sensing voltage input shutdown
(D) BRUSHLESS ALTERNATOR:- (i) Alternator coupled to engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation. Brush less alternator shall be confirming to BS- 5000 or relevant of IS-4722 (ii) Type :- self excited self regulated with automatic voltage regulator (iii) Rating:- 30 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition (iv) Speed- 1500 RPM (v) System -415 V + 2.5% AC 3 phase 4 wire 50 Hz. (vi) Connection - 4 wire star connected (vii) Enclosure -Screen projected drip proof (viii) Ventilation - self ventilated (ix) Insulation -Insulation, class H , IP-23 (E) Sub base Fuel tank 14 SWG MS sheet and capacity to hold diesel sufficient for running 08 hours at full load including (i) Level indicator on fuel tank. (ii) Drain plug (iii) Piping for fuel tank as per manufecturer design (iv) Fuel strainer. (v) Air vent, Fuel tank shall be mounted as per manufacturers instruction (F) Battery :as provided by OEM (G) Base plate : fabricated out of MS channels ISMC of suitable size suitable for fixing DG set all as specified by the manufacturers (Necessary permission/ certificate from Central State pollution Control Board shall be accomplished with DG set) CPCB II
(G) AMF PANEL OUTDOOR TYPE: The AMF Panel Outdoor type suitable for 30 KVA DG Set factory made out of CRCA Steel 3 mm thick Sheet floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel would be powder coated minium thickness of 50 microns, stove enameled paint finished after elaborate pretreatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :- (a) HRC Fuse with fuse base,Din type 63A-06 No (b) Current transfrmer,CL-1,5 VA,100 /5A-04 No. (c) Four pole Contactor, 240 V AC,2 NO +2 NC,63 A, AC3-02 Nos for (DG Set & Commercial). (d) Indicating Lights R ,Y,LED type,240V AC -04 No. (e) Indicating Lights B,LED type,240V AC -02 No. (f) Illu Push Button with elements ,LED type -NO/NC-01 No. (g) Mushroom head push button,Press to lock,Turn to release-01 No. (h) KW/PF/KWH meter 96 x 96 sqmm ,3 Phase Digital type 415 V AC-01 No. (j) DC Ammeter 96 x 96 Sqmm,Digital type 0-20 A -01 No. (k) 12 V, 10 A DC Automatic Battery Charger with inbuilt trickle / boost facality-01 No (l) 4 Point Alarm Annuciator with inbuilt Hooter,Test,Accept & Reset Push button. (m) Solid state single element earth fault relay with 2 c/o contact, CTR-250/5A ,Aux supply 230V AC - 1 No. (n) AMF Controller,12 V DC - 01 No. (o) Aux relay,Coil voltage,24V DC,4C/O,14 PIN-24V DC-06 Nos (p) Thermal O/L Relay,with inbuilt SPP Feature.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core (Main elect supply to be taken from existing MT bldg Tr ) complete all as specified & directed.
M & L for Earthing complete with GI earth plate electrode 600x600x5 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GIearth strip of 32x6 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 3 of SSR part 1 including Charcoal, Rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel 32 mm dia light grade for protection of earth electrode 20 mm dia for watering all as speicified and directed and tested on completion. Note : - The unit rate quoted shall deemed to have included for GI protection pipe, GI earth strip up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete all as specified.
Excavation in trenches,in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 m in wide for laying of cable,RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified & directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified. (Note:-The back fill shall be neatly rounded/levelled over the trench to a sufficient height to allow for settlement to the required level all as specified in clause 18.56.6(a) of SSR-2009)
M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Punned down thickness shall be measured for payment.
Supply and laying factory made unreinforced precast concrete cable cover, class LV type 1, flat size 250mm x 150mm x 40mm laid transverse to cable complete all as specified & directed.
Sukhi Electricals
GEE CEE ENTERPRISES
M/s. Shree Shakti Enterprise
SHREE CHAMUNDA CONSTRUCTION WORK
Venus Engineering
NEELKANTHA ASSOCIATE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .