Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.3 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹92.6 L+₹5.2 L (5.98%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 BIDDER |
Tender Value
₹88.2 L
EMD Value
₹1.6 L
Closing Date
15 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
PROVN OF WORKS SERVICES FOR INSTALLATION OF AAGs AT AF STN BHUJ
2022_MES_561111_1
8616/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE (AF) BHUJ
₹1.6 L
Yes
16 Jan 2023
3 Nov 2022
17 Dec 2022
3 Nov 2022
15 Dec 2022
3 Dec 2022
8 Nov 2022 - 12 Nov 2022
Amount
Demolition of cement concrete (un-reinforced) of any description and any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
Surface excavation n. exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Excavating over area n. exc. 1.5m deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Excavating over area exc. 1.5m but n. exc. 3.0 m deep and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials to a distance exceeding 500km but not exceeding 1.5 km and depositng where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Removing building materials etc. (other than spoil earthwork) to a distance of upto 1.00 Km beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
Forming embankments including raising (or lowering) earth, spreding in layers n exc. 30 cm thick ; watering, ramming/rolling and finishing to required size, shape, etc. n exc. 1.5 Mtr high form base in soils. complete all as specified and directed by Engineer-in-Charge. Note:- Rolling shall be done using power roller of 8 to 10 tonne capacity to achive 98% compaction.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Material & labour for plain Cement concrete, type D2, (1:4:8), (using 40mm graded stone aggregate) in foundation, sub basees and filling mass concrete complete all as specified and directed by Engineer-in-Charge.
Material & labour for 30 mm thick dry sand filling under interlocking tiles including spreading levelling, watering and consolidation complete all as specified and directed by Engineer-in-Charge
Material & labour for machine pressed pre-cast concrete interlocking paver block factory manufactured and shape/design and size IS-15658-2006 marked of 80 mm thick M-40 grade casted with grey cement and pigment base laid in required pattern complete all as specified and as directed by Engineer-in-Charge. (Note colour of interlocking paver block shall be approved by the GE)
Material & labour for 100mm thick PCC-1:2:4 type B1 (using 20 mm graded stone aggregate) as in edge restrin to interlocking tiles, kerbs and the like including weathering slightly rounded as chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge.
Material & labour for reinforced ready mix concrete design mix M-35 in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material & labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and softs (if any) of foundation and plinth beams, and similar work, vertical or to batter for fair finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge
Material & labour for formwork to sides of pillars, posts, struts, piers, columns and stanchions circular on plan complete all as specified and directed by Engineer-in-Charge.
Supply & fix TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge.
Material & labour for harcore of guage not exceeing 63mm depositing and ramming to a true surface complete all as specified and directed by Engineer-in-Charge
Supplying and laying of 150 mm inner dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings but with CPVC schedule 40 pipes & plain schedule 80 fittings in trenches complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 250 mm inner dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings but with CPVC schedule 40 pipes & plain schedule 80 fittings in trenches complete all as specified and directed by Engineer-in-Charge.
Supply & fix TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge.
Supply & fix hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt weight per square metre exc 4 kg complete all as specified and directed by Engineer-in-Charge
Supply & fix plates Fe-410- W(Gde- E-250) quality- B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Steel shim of size 150mm x 150mm x 25mm- 16 nos) complete all as specified and directed by Engineer-in-Charge.
Material & labour for 10 mm thick screed bedding in CM 1:4 over concrete surfaces, finished even and smooth without using extra cement with water proofing compound @ 3% by wt of cement or as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge( WPC shall be paid separately).
Supply only integral water proofing compound ISI marked complete all as specified and directed by Engineer-in-Charge
Material & labour for APP based polymeric membrane minimum weighing 1.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed by Engineer-in-Charge
Material & labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed by Engineer-in-Charge.
Supply & fix grating square 150 mm size of PTMT (Minimum weight 100gms) complete all as specified and directed by Engineer-in-Charge.
Forming 20mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed by Engineer-in-Charge.
Material & labour for laying 2mm thick conductive type epoxy based polyurethane coating of approved colour laid for smooth , easily cleanable glossy finished surfaces. The mixing and laying has to be completed within the pot life of the product complete all as specified and directed by Engineer-in-Charge.
Forming mortice holes exc 50 but n exc 100 cm for balusters, newels, rag-bolts, etc. and grouting with SIKA GROUT 212 or equivalent after balusters, etc. are fixed complete all as specified and directed by Engineer-in-Charge. Note:- (i) Grouting will be carried out during the installation period of equipment in presence of Agency Rep. (ii) Grout is to be flow able, non-shrinking type having a compressive strength of 5000 PSI (35MPA) in 28 days. (iii) Contractor will perform grouting work and provide all the T&P, Material for Grouting work.
Fixing/Installation of AAG equipment/machinary at each required location which includes all necessary equipments such as cranes/Equipment for placement, Tape installation, Tape Tracking and including necessary Testing etc complete all as specified and directed by Engineer-in-Charge. Note:- (i) Tape Reeving and Alignment, Proof loading, synchronization and final check/battery position,etc all operations will be performed after machinery installation in presence of company rep. (ii) Final alignment is accomplished by pulling the tape from each energy absorber, against a minimum static pressure of 100 PSI. (7 BAR), applied to the brakes. A vehicle having a minimum draw bar capability of 18,000 Lbs. (8,200 Kg.) is required. (iii) Fork lift, heavy vehicle and necessary manpower as given in PS shall be made available by contractor to agency rep during testing.
Supply , laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge
Supply , laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in Soft/ loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flate size 250mm X 150 mm X 40 mm in trenches as protection to LT UG cable complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB distribution board made of sheet metal enclosures double door type (CRCA sheet) dust and vermin proof , TPN 4 way with 200 Amps rated bus bar and copper connector and IP 43 protection, 220 volt , fixed on wall complete with blanking plate complete all as specified and directed by Engineer-in-Charge
Supply & fix MCB TPN 40 Amps 240 Volt complete all as specified and directed by Engineer-in-Charge
Supply & fix MCB SP 6 to 32 Amp , 230 volts C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
Material & labour for submain wiring complete with 2x2.5 sqmm (nominal area) PVC insulated copper conductor FRLS cable (ISI marked) in and including steel conduit (medium quality ISI marked) and fixed on surface/ wall including 2.5 sqmm single core copper earth wire to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge
Supply, febricate, testing and commisioning of factory made LT out door distribution panel / Junction box Single door of size 600x600x450 mm including locking arrangment cubical type dust proof , weather proof , vermin proof asthetically designed, having atleast IP -54 degree of ingress protection , fabricated from 3 mm thick CRCA sheet with front & rear opening including bus bar chamber , 4 strips of copper bus bar of 200 Amps capacity, insulated color sleaves, procelain/epoxy insulators, rail channels cable alloy including made out of 14 guage MS sheet over angle iron frame of size 50x50x6mm , 60 cm grouted in ground floor and 60 cm above GL including necessary excavation ,foundation .PCC etc complete duly powder coated of approved color complete all as specified and directed by Engineer-in-Charge
Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6.3 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE/GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore , wire mesh and lugs, test point etc. complete. Note: G I strip exceeding 7.5m long shall be measured & paid seperately.
Material & labour for earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground vertically to depth not less than 2.25mtr below ground level with top edge of earth plate at a depth not less than 1.5mtr below normal ground level connected to and including copper strip of 20x3mm as earth lead upto 7.5mtr long fixed by means of bolts, nuts, check nuts and washers etc. of brass including provn of GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch 40, wire mesh and lugs, test point etc. complete. Note: copper strip exceeding 7.5m long shall be measured & paid separately.
Supply and fixing copper bonded rod of size not less than 5/8" (16mm) in diameter and 10'-0"( 3050mm) long, driven for full length in to the earth. The maximum reasistance of the ground shall not exceed 25 Ohms under normal dry conditions. Resistance test shall not be made immediately after a rain. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing AWG 4 solid bare copper conductor for the connection between the ground rod and the foundation rebar with necessary ground clips and fittings complete all as specified and directed by Engineer-in-Charge
Material & labour for 20 mm dia UPVC tubing standard duty with threaded at both ends to be fixed in foundation complete all as specified and directed by Engineer-in-Charge
Supply and fix air termination single pointed solid copper rod 12mm dia, 300mm long mounted on GI pipe 40mm bore light grade embedded in mass PCC complete all as specified and directed by Engineer-in-Charge. (Note :G I Pipe & PCC shall be measured and paid separately.)
Supply & fix copper strip 20 x 3.15 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etccomplete all as specified and directed by Engineer-in-Charge.
Supply & fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge.
Material & labour for boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using necessary machine including supply & inserting HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and directed by Engineer-in-Charge. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
Supply and laying GI tubing 50 mm dia bore light grade laid in trenches / floor / fixing on pole / wall / roof for cable protection/fixed on roof for fixing of sheet with necessary fittings complete all as specified and directed by Engineer-in-Charge.
Supply and installation of secondary connector for 6 Sqmm /4 sqmm/2.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and installation of Primary connector kit for 6 Sqmm complete all as specified and directed by Engineer-in-Charge.
Removing of air filled lightning equipment primary cable of size 6 sqmm single core six stranded 5 KV rating flexible bore copper conductor class 5 special cross linked elaslomer insulation, oil resistant eleaslomer, Colour: Black. Max core temperature 85o C connection between transformers and light in HDPE pipe conduit complete all as specified and directed by Engineer-in-Charge.d. ( Excavation and earth work considered separetely)
Dismantling of GI earth wire for reuse as existing complete all as specified and directed by Engineer-in-Charge.
Material & labour for GI earth wire SWG 4mm dia complete all as specified and directed by Engineer-in-Charge.
Supply laying, testing and commissioning of Airfield lighting equipment Primary cable of size 6sqmm single core in HDPE pipe of size 50mm , 450/750V, Conductor flexible bore copper conductor class 5 special cross linked elaslomer insulation, oil resistant eleaslomer, colour - black, Max core temprature -85° C, connection between transformers and light complete all as specified and directed by Engineer-in-Charge. Note: HDPE pipe will be paid separately under respective item
Supply and lay heavy duty HDPE pipe of size 50 mm dia, PN 10 for inserting AFLS cables complete all as specified and directed by Engineer-in-charge.
Dismantling safely without any breakage Runway Elevated Fittings, Runway Taxiway edge light white dome Frangible body on hinged arrangements 150W or 200W pre-focus or bi-pin halogen lamp and depositing to CCR complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MAFI AFLS runway edge inset bidirectional clear light of 2X105 Watt rating with 12 inch shallow base incl suitable adhesive complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Aviation obstruction light LED base single emitter type on building complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI tubing 20 mm dia bore light grade fixing on pole / wall / roof for air termination rod fixing on roof with necessary fittings complete all as specified and directed by Engineer-in-Charge.
Material & labour for 18 mm thick (compacted) sand filling in trenches including watering and well ramming complete all as specified and directed by Engineer-in-Charge.
MUKUL ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .