Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 22 1 48 1 CHENGALARAOPETA BEACH ROAD VISAKHAPATNAM ANDHRA PRADESH 530001 | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | Admitted-Finance |
| 4 | Rejected-Technical 37 8 1 MANCHUKONDA GARDENS INDUSTRIAL ESTATE P O VISAKHAPATNAM ANDHRA PRADESH 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | Rejected-Technical Technically Unsuitable |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
7 Jul 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager SRC-Com
SR Complex Hindustan Shipyard Limited Gandhigram Visakhapatnam 530 005
Works on Accommodation AC System and Domestic Fridge System on MV Swaraj Dweep
2021_HSL_86412_1
20/21997/023/2021-22
Open Tender
Miscellaneous Services
Service
45 days
HSL Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
Yes
HSL
₹10,000
Yes
12 Jul 2021
28 Jun 2021
7 Jul 2021
28 Jun 2021
7 Jul 2021
28 Jun 2021
120 days
Amount
ACCOMMODATION AC SYSTEM - 03 UNITS. Make: SABROE.Type:- SAB 163 MK3 Screw type compressor using R-22. Controls: Unisab III. Version 1.10.7. Following repairs to carry out on air conditioning system. After the repairs, Satisfactory operation of all three AC plants to be shown to ship staff and HSL.
Entire Gas to collect from each system by using recovery units in empty cylinders. Contractor is to arrange recovery units and dry ice with competent operators. After completion of repairs each system to be pressure tested to 20 bar with nitrogen and check for leaks. After satisfactory pressure testing, system to keep under vacuum for 24 hours. Supply of Nitrogen is to be covered in Contractor's Scope.While pressure/vacuum testing of AC system, leaks to be rectified.Each system to charge with Freon gas (R-22). The above recovered gas to be pumped in system first and then additional gas whatever required to be charged.Supply of additional gas in contractor scope. Each system needs around 400 kg of gas.( R-22 Gas).Contractor Procure and supply of approximatly 900 kg of Freon R-22 in re-fillable cylinders for 3 plants. After charging the gas into AC system, empty cylinders will be returned.
All filters in each system to renew. Filters - Ship supply.
Intermediate valves 06 nos in each system are not holding. All valves to overhaul with new teflon seat & O'rings. Procurement and Fitment of Teflon seat & O'rings are covered in Contractor's Scope.
System lub oil to be drained and oil filter to be renewed. Fresh lub oil to be taken into the system upto normal level. Supply of Spares / material is covered in Contractor's Scope.
STBD lub oil pump and its motor to be overhauled and pump shaft seal to be renewed. Procurement of Shaft seal is covered in Contractor's Scope.
Consumables / Components / Items / Spares / Material: For executing of the above mentioned jobs, Contractor has to procure, supply all items and fitted in its place. Contractor has to quote lumpsum cost for required Consumables / Components / Items / Spares / Material mentioned at S.Nos. 1 to 1.05 for above scope of work. The taxes will be paid as per actuals. The cost of spares quoted by the contractor will be considered " on not exceeding basis of total lumpsum cost mentioned in the BOQ for this line item'' for satisfactory completion of the specified SoW. Payment will be made at actuals on not exceeding quoted cost of this Serial (1.06) against third party/OEM invoice.
A/C UNIT-2 CONDENSOR TO CONVERT AS GAS RECOVERY POINT. Present A/C unit -2 is out of commission with out motor, compressor and few pipe lines. Consider converting AC unit- 2 condensor to common gas recovery point for other three working A/C units. For this the following to be carried out.
Condenser end covers on cooling sea water side to open and clean tubes thoroughly. After cleaning same to subject to pressure test and check any tube leakage. After test covers to box back.
A/c unit-2 Condenser gas side pipe lines to modify suitably with valves such that gas can be received from the other three working units in case gas recovery is required. Also, gas can be charged to the other three working units in case gas charging is required. Required Spares / Material and consumables Supply and fitment is covered in Contractor's Scope.
Consumables / Components / Items / Spares / Material: For executing of the above mentioned jobs, Contractor has to procure, supply all items and fitted in its place. Contractor has to quote lumpsum cost for required Consumables / Components / Items / Spares / Material mentioned at S.Nos. 2 to 2.02 for above scope of work. The taxes will be paid as per actuals. The cost of spares quoted by the contractor will be considered " on not exceeding basis of total lumpsum cost mentioned in the BOQ for this line item'' for satisfactory completion of the specified SoW. Payment will be made at actuals on not exceeding quoted cost of this Serial (2.03) against third party/OEM invoice.
DOMESTIC FRIDGE SYSTEM - CONTROL SYSTEM - SABROE UNISAB II , COMPRESSORS - BOCK AAPHUS DENMARK - TYPE FX-5.
Gas is to be collected in empty bottles by using recovery unit. Empty Bottles/recovery unit and dry ice to be arranged and after the repairs/overhauling same gas is to be charged into the respective system. Additional charging of freon R22 will be supplied by Contactor only. Approx. Gas Qty is 120 Kg. Arrangement of Dry ice and recovery units are covered in Contractor's Scope. After the repairs, Satisfactory operation of Domestic Frdge Systems to be shown to ship staff and HSL.
Complete system (Meat, Fish, Veg & Dairy Rooms) to be blown through by Nitrogen to remove trapped oil from the Evaporators, system to be pressure tested, vacuumised.While pressure/vacuum testing of system, leaks to be rectified and after charging gas satisfactory temperature to be shown to ship’s staff. Supply of required Nitrogen is covered in Contractor's Scope.
All 03 in no. fridge compressor safety device including LP, HP and Differential oil pressure is to be checked and made operational/ renewed as per sample. Procurement and fitment of LP, HP and Differential oil pressure devices are covered in Contractor's Scope.
Four in no. shut off valves for driers, spindles head rounded off and glands leaking, same is to be replaced with new one and gland to be packed. (valve size 16 mm); Material: spindles, glands, shut off valves are to supply and fitment is included in Contractor's Scope.
Evaporater heating coils are to be made and supplied as per sample. 08 in nos heating coils supply and fitment is included in Contractor's Scope.
Fridge condensor to be cleaned and end cover partition damaged to be repaired / renewed. One set spare end covers to be manufactured and supplied by Contractor only. Materials: chemical, end cover builtup works, machingworks, grinding works & Procurement and fitment of zinc anods, purging cocks, paint, copper plugs, joints, o-rings are covered in Contractor's Scope.
Consumables / Components / Items / Spares / Material: For executing of the above mentioned jobs, Contractor has to procure, supply all items and fitted in its place. Contractor has to quote lumpsum cost for required Consumables / Components / Items / Spares / Material mentioned at S.Nos. 3 to 3.06 for above scope of work. The taxes will be paid as per actuals. The cost of spares quoted by the contractor will be considered " on not exceeding basis of total lumpsum cost mentioned in the BOQ for this line item'' for satisfactory completion of the specified SoW. Payment will be made at actuals on not exceeding quoted cost of this Serial (3.07) against third party/OEM invoice.
SRI SRINIVASA ENGINEERING WORKS
POSITIVE CONTROLS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .