| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAdmitted-Finance C 111 STATION PLAZA STATION ROAD STATION ROAD BHANDUP W MUMBAI 400078 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Admitted-Finance | |
| 2 | L2₹20.7 L+₹17.5 L (552.1%)Admitted-Finance 1 212 V P ROAD AZHEEKKAL ERNAKULAM KERALA 682508 | ERNAKULAM | KERALA | 682508 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical TECHNICALLY NOT QUALIFIED | |
| 4 | Rejected-Technical | - | Rejected-Technical TECHNICALLY NOT QUALIFIED | |
| 5 | Rejected-Technical | - | Rejected-Technical TECHNICALLY NOT QUALIFIED |
| Sl No | Description | Qty | Unit | shine industries L1 | SEABLUE SHIPYARD LTD L2 |
|---|---|---|---|---|---|
| 1.00Pressurising and proving of APT as mentioned below:- | |||||
| 1.01 | Proving of APT in presence of user dept and ship staff. Test parameters involve building up 150 mm pressure(by water column) in each cluster being tested, with any pressure drop restricted below 13 mm in 10 minutes. Calibrated U-tube manometers are to be used. Suitable air pressure and air flow rate generation devices to be arranged by the firm for the test.
Acceptance Agency: APT will be offered to external agency, Hull Inspection and Trials Unit, Kochi (HITU) for acceptance.
Inspection Stages:
(i) On rectification of Defects Indicated.
(ii) Proving Validity of repairs by Air Pressure Test. | 1 | LS | 25,000 ₹99,000 Lowest | 1,95,000 ₹6,44,679 |
| 2.00Renewal of rubber beading of following doors and hatches:- | |||||
| 2.01 | WT Doors – Renewal of rubber coming, Locking Mechanism and packing of glass | 1 | LS | 1,500 ₹9,900 Lowest | 22,500 ₹1,01,875.2 |
| 2.02 | Hatches – Renewal of rubber coming, Locking Mechanism and packing of glass | 1 | LS | 1,300 ₹8,250 Lowest | 18,450 ₹75,292.14 |
| 3.00 | Structural repairs on WT/GT doors and hatches | 1 | LS | 2,000 ₹11,550 Lowest | 21,750 ₹69,243.3 |
| 4.00 | Removal, Repairs/overhauling and fitment of SOQC valves | 1 | LS | 1,800 ₹9,900 Lowest | 12,500 ₹54,121.2 |
| 5.00Removal, repairs/overhauling and fitment of WT sluice valves as mentioned below:- | |||||
| 5.01 | Water Tight Sluice Valve - Removal, overhauling, refitment, including replacing damaged/missing valve wheels and flaps opening of removed valves on trunking to be temporarily blanked for APT. | 1 | LS | 2,000 ₹11,550 Lowest | 14,250 ₹56,508.9 |
| 6.00Overhauling of mushroom heads, ventilation flaps as mentioned below:- | |||||
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
7 Oct 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE ADMIRAL SUPERINTENDENT
NSRY KOCHI
REPAIR RATE CONTRACT FOR AIR PRESSURE TEST (APT) OF CLUSTERS ON BOARD IN SHIPS
2021_NAVY_476297_1
PP/01/1000/RRC/APT/21-24
Open Tender
Marine Services
Item Rate
1095 days
AT KOCHI
THE FIRM SHOULD HAVE SUITABLE FACILITY, SUFFICIENT INFRASTRUCTURE SETUP AT KOCHI AND MANPOWER FOR 24X7 SUPPORT FOR UNDERTAKING THE APT OF CLUSTERS ON BOARD IN SHIPS
9 documents required · 9 mandatory
₹0
₹3.5 L
Yes
NSRY, Kochi
20 Nov 2021
18 Sept 2021
8 Oct 2021
18 Sept 2021
7 Oct 2021
1 Oct 2021
19 Sept 2021 - 23 Sept 2021
24 Sept 2021
180 days
Amount
Pressurising and proving of APT as mentioned below:-
Proving of APT in presence of user dept and ship staff. Test parameters involve building up 150 mm pressure(by water column) in each cluster being tested, with any pressure drop restricted below 13 mm in 10 minutes. Calibrated U-tube manometers are to be used. Suitable air pressure and air flow rate generation devices to be arranged by the firm for the test. Acceptance Agency: APT will be offered to external agency, Hull Inspection and Trials Unit, Kochi (HITU) for acceptance. Inspection Stages: (i) On rectification of Defects Indicated. (ii) Proving Validity of repairs by Air Pressure Test.
Renewal of rubber beading of following doors and hatches:-
WT Doors – Renewal of rubber coming, Locking Mechanism and packing of glass
Hatches – Renewal of rubber coming, Locking Mechanism and packing of glass
Structural repairs on WT/GT doors and hatches
Removal, Repairs/overhauling and fitment of SOQC valves
Removal, repairs/overhauling and fitment of WT sluice valves as mentioned below:-
Water Tight Sluice Valve - Removal, overhauling, refitment, including replacing damaged/missing valve wheels and flaps opening of removed valves on trunking to be temporarily blanked for APT.
Overhauling of mushroom heads, ventilation flaps as mentioned below:-
Ventilation Flaps – Removal, overhauling, refitment, including replacing damaged/missing valve wheels and flaps opening of removed valves on trunking to be temporarily blanked for APT.
Mushroom Heads - Removal, overhauling, refitment, including replacing damaged/missing valve wheels and flaps opening of removed valves on trunking to be temporarily blanked for APT.
Packing of cable glands and cable conduits as mentioned below:-
Cable Glands – Dimension 50x40cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Cable Glands – Dimension 30x20cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Cable Glands – Dimension 20x15cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Cable Glands – Dimension 15x10cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Cable Glands – Dimension 05x05cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Cable Glands – Dimension 8cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Cable Glands – Dimension 10cm. rectification of all additional defects precluding proving of APT ( Including air leaks from glands/joints/deckconducts,rubber coaming etc.). Packing and sealing of cable glands with silicone sealant, araldite and hardener to prove WT integrity.
Manufacture and fitment of blanks, ITPs as mentioned below:-
Indicator Test Plug – Manufacture and Fitment
Blanking and seaming of pipes – Dia 150 – 100 mm. Rectification of all additional defects precluding APT ( Including air leaks from glands/joints/deck conducts/rubber coaming etc.) Blanking and sealing of pipes tom prove WT integrity of compartment.
Blanking and seaming of pipes – Dia 96 – 75 mm. Rectification of all additional defects precluding APT ( Including air leaks from glands/joints/deck conducts/rubber coaming etc.) Blanking and sealing of pipes tom prove WT integrity of compartment.
For material - Blanking and seaming of pipes – Dia 74 – 50 mm. Rectification of all additional defects precluding APT ( Including air leaks from glands/joints/deck conducts/rubber coaming etc.) Blanking and sealing of pipes tom prove WT integrity of compartment.
For material - Blanking and seaming of pipes – Dia less than 50 mm. Rectification of all additional defects precluding APT ( Including air leaks from glands/joints/deck conducts/rubber coaming etc.) Blanking and sealing of pipes tom prove WT integrity of compartment.
Degutting and regutting of panels, insulation etc as mentioned below:-
Removal and fitment of bulkhead,deckhead and ship’s side covering MFMB lagging/cladding/panels/acoustic panels to provide access to bare metal for conduct of APT and identification of leaks. The items removed are to be replaced on clearance. MFMB sheets for lagging will be provide by the yard.
Renewal of deck plates in way of proving APT
Build up weld seam and pitted surface on decks and bulkheads.
Renewal of deck plates in way of APT defects (Mat – DMR 249, thickness below 8mm)
Renewal of deck plates in way of APT defects (Mat – AL)
Miscellaneous repairs as part of APT as mentioned below:-
Patholes – Renewal of rubber coming, Locking Mechanism and packing of glass
Air Hose Test
SEABLUE SHIPYARD LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .