Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Accept |
| 2 | Accepted-Technical | Accepted-Technical Accept |
| 3 | Accepted-Technical | Accepted-Technical Accept |
Tender Value
₹3.8 L
EMD Value
₹7,605
Closing Date
24 Apr 2026, 10:30 amClosed
EE Jal Shakti Division Thural
EE Jal Shakti Division Thural
RRD of LWSS Patbag Linjhan in Tehsil Palampur Distt. Kangra (HP) (SH Repair of 5 HP and 30 HP auto starter panel)
2026_HPIPH_134210_1
EE/JSVD/THL/2026-27-452-85 Dt. 13.04.2026
Open Tender
Repair and Maintenance Services
Item Wise
30 days
EE Jal Shakti Division Thural
Please refer Tender documents.
8 documents required · 8 mandatory
₹350
₹7,605
30 Apr 2026
13 Apr 2026
24 Apr 2026
13 Apr 2026
24 Apr 2026
13 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Replacement & Installation of electronics instruments 5 HP X 1 X 2 Starter having panel serial no. AEPL/ ECP/ 2022-23/ 172 Replacement of energy saving variable Frequency module of 5 HP X 1 X 2 Heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be capable to monitor & control the frequency of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. | - | Job | - | - |
| 2 | Replacement & Installation of Multifunction meter to showing the degital opration like Amp. Voltage, frequency, PF Complete in all respect as per the direction of Engineer in charge with in all leads and lifts. | - | No | - | - |
| 3 | Replacement and installation of surge Protection Device used for safeguard sensitive electronic equipement from voltage spikes and surge. They are crucial for protecting against voltage inconsistencies caused by lightning strikes, Power surge or electrical malfunctions complete in all respect as per direction of Engineer in charge with in all leads and lifts. | - | No | - | - |
| 4 | Replacement & installation of LED Three phase indicating lamps complete with logged switches for individual motors confirming to BIS 3452 (Part I & II) Latest with upto date ammendments. complete in all respect as per direction of Engineer in charge with in all leads and lifts. | - | No | - | - |
| 5 | Labour and service charges complete in all respect as per direction of Engineer in charge with in all leads and lifts. | - | Job | - | - |
| 6 | Repaired and replacement of electronics instruments of 30 HP X 1 X 2 Starter having panel serial no. AEPL/ ECP/ 2022-23/ 172 Replacement of Energy saving variable Frequency module of 30 HP X 1 X 2 heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be cabable to monitor & control the frequency of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 degrees celcius without derating and have conformal coating class 3C2, So that it can work in any harsh environment like moisture etc. complete in all respect as per direction of Engineer in charge with in all leads and lifts. | - | Job | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
Form6.pdf
Tender Documents • 0.43 MB
Form8.pdf
Tender Documents • 1.22 MB
BOQ_198463.xls
BOQ • 0.28 MB
Termsandconditions.pdf
Additional Documents • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .