Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | ₹5.3 L Quoted ₹5.4 L | L1 | Accepted-AOC THROUGH OPEN TENDER |
| Sl No | Description | Qty | Unit | AARON ENGINEERING L1 |
|---|---|---|---|---|
| 1.00Air Pre Heater repairing works in Boiler # 4, 5, 6 & 7 at Energy - Mechanical (The rate quoted is exclusive of GST) | ||||
| 1.01 | Removal of Eroded Ferrules on Top side of APH and Replacement with new Ferrules and Tag Welding (SS). L & T make Staintrode-D Welding Electrodes should be used. Length-120 mm | 1,000 | NUMBER | 180 ₹1.8 L |
| 1.02 | Removal of Old MS Protruded Pipes on Bottom side of APH by Gas Cutting / Grinding and Replacement with new Ferrules and Stitch Welding (SS). L & T make Staintrode-D Welding Electrodes should be used. Length-175 mm | 50 | NUMBER | 385 ₹19,250 |
| 1.03 | Air Leak Test and Dummying Leaky APH tubes on both the sides using 6mm thk MS Plate and Seal Welding using ESAB 6013 Welding Electrode (ESAB - 28) | 1,000 | NUMBER | 345 ₹3.5 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
20 Dec 2025, 3:00 pmClosed
GM (TOS and STORES)
TOS KAGITHAPURAM
Air Pre Heater repairing works in Boiler # 4, 5, 6 and 7 at Energy Mechanical
2025_TNPL_624374_1
TNPL / TOS / U1/252613005619
Open Tender
Boiler related works
365 days
TOS KAGITHAPURAM
Bidders must have experience in carrying out similar type of work or any boiler related works in any Industry. Reference documents towards experience must be submitted along with price bid.
3 documents required · 3 mandatory
₹0
₹7,500
18 Feb 2026
18 Nov 2025
22 Dec 2025
18 Nov 2025
20 Dec 2025
18 Nov 2025
Amount
Air Pre Heater repairing works in Boiler # 4, 5, 6 & 7 at Energy - Mechanical (The rate quoted is exclusive of GST)
Removal of Eroded Ferrules on Top side of APH and Replacement with new Ferrules and Tag Welding (SS). L & T make Staintrode-D Welding Electrodes should be used. Length-120 mm
Removal of Old MS Protruded Pipes on Bottom side of APH by Gas Cutting / Grinding and Replacement with new Ferrules and Stitch Welding (SS). L & T make Staintrode-D Welding Electrodes should be used. Length-175 mm
Air Leak Test and Dummying Leaky APH tubes on both the sides using 6mm thk MS Plate and Seal Welding using ESAB 6013 Welding Electrode (ESAB - 28)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.68 MB
BOQ_746670.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid