Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC | ₹40.3 L | L1 | Accepted-AOC LOWEST BID |
| 2 | L2₹45.0 LRejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹45.0 L | L2 | Rejected-Finance HIGHER BID |
| 3 | L3₹49.1 LRejected-Finance WANIAWAD BHUJ KUTCH PIN 370 001 | KACHCHH | GUJARAT | 370001 | ₹49.1 L | L3 | Rejected-Finance HIGHER BID |
| 4 | L4₹52.2 LRejected-Finance | ₹52.2 L | L4 | Rejected-Finance HIGHER BID |
| Sl No | Description | Qty | Unit | Sai Ram Electricals and Refrigeration Works L1 | machine vision plus L4 | M/s Bombay Novelty Stores L3 | Abhishek Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting outcomplete all as specified and directed. | 190 | Sqm | 50 ₹9,500 | 100 ₹19,000 | 85 ₹16,150 | 75 ₹14,250 |
| 2.00 | Excavation in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10sqm on plan and n 'exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed. | 60.75 | CUM | 400 ₹24,300 | 350 ₹21,262.5 | 335 ₹20,351.25 | 325 ₹19,743.75 |
| 3.00 | Excavation in trenches n.exc. 1.5m wide and exc 1.5 m & n exc 3m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10 sqm on plan and getting out in SDR ROCK complete all as specified and directed. | 10 | CUM | 400 ₹4,000 | 850 ₹8,500 | 1,150 ₹11,500 | 1,150 ₹11,500 |
| 4.00 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed | 16 | Each | 150 ₹2,400 | 350 ₹5,600 | 335 ₹5,360 | 250 ₹4,000 |
| 5.00 | M & L for cement concrete in foundations filling and mass concrete type B2 1:2:4 (using 40 mm graded aggregate) complete all as specified and directed. | 2 | Cum | 5,000 ₹10,000 | 5,000 ₹10,000 | 4,454 ₹8,908 | 4,500 ₹9,000 |
| 6.00 | Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed. | 265.5 | CUM | 70 ₹18,585 | 200 ₹53,100 | 140 ₹37,170 | 110 ₹29,205 |
| 7.00 | Removing excavated soil/ materials to a distance not exc 50 mtr but n.exc and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed. | 43.95 | CUM | 80 ₹3,516 | 250 ₹10,987.5 | 110 ₹4,834.5 | 90 ₹3,955.5 |
| 8.00 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 10 cm thick, watered and rammed to a true surface complete all as specified directed. | 17 | CUM | 2,400 ₹40,800 | 2,000 ₹34,000 | 1,975 ₹33,575 | 2,150 ₹36,550 |
| 9.00 | M & L for Cement concrete in foundations, filling and mass concrete using type D2 1:4:8 (using 40 mm gradaed aggregate). complete all as specified and directed. | 17 | CUM | 3,200 ₹54,400 | 4,500 ₹76,500 | 4,600 ₹78,200 | 450 ₹7,650 |
| 10.00 | M&L for 50mm thick cement concrete type B-1,1:2:4 ( using 20mm graded aggregate) 50 mm thick complete all as specified and directed. | 185 | SQM | 200 ₹37,000 | 450 ₹83,250 | 420 ₹77,700 | 490 ₹90,650 |
Tender Value
₹44.8 L
EMD Value
₹89,560
Closing Date
11 Apr 2026, 6:00 pmClosed
GE ARMY
BHUJ
AUGMENTATION OF SWM SYS AT BHUJ MIL STN UNDER GE (ARMY) BHUJ
2024_MES_682641_8
8253
Open Tender
Civil Works
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹89,560
Yes
18 Jun 2026
14 Mar 2026
13 Apr 2026
14 Mar 2026
11 Apr 2026
28 Mar 2026
M&L for Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting outcomplete all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10sqm on plan and n 'exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and exc 1.5 m & n exc 3m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10 sqm on plan and getting out in SDR ROCK complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed
M & L for cement concrete in foundations filling and mass concrete type B2 1:2:4 (using 40 mm graded aggregate) complete all as specified and directed.
Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed.
Removing excavated soil/ materials to a distance not exc 50 mtr but n.exc and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 10 cm thick, watered and rammed to a true surface complete all as specified directed.
M & L for Cement concrete in foundations, filling and mass concrete using type D2 1:4:8 (using 40 mm gradaed aggregate). complete all as specified and directed.
M&L for 50mm thick cement concrete type B-1,1:2:4 ( using 20mm graded aggregate) 50 mm thick complete all as specified and directed.
M&L for precast concrete block masonary with PCC solid blocks in (1:2:4), type B1 (using 20mm graded stone aggregate) exceeding 10cm in width andsetting in Cm (1:4) complete all as spd and directed.
M&L for 15 mm rendering in two layers with 10 mm with CM 1:6 & 5 mm thick with CM (1:4) with using water proffing compound on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified (Note: WPC will be paid seprately.)
Supply only Water Proofing compound complete all as specified and as directed.
M & L for rendering 10mm thick in cement mortar 1:6 on Block/Brick masonry surfaces of internal wall finished even and smooth complete all as specified and as directed.
M&L for preparation of surfaces and applying 02 coats of exterior emulsion paint over new surfaces(light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (APEX) / Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) .
M&L for applying acrylic wall care putty on new plastered internal/External surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE /Engineer-in-Charge.
M&L for preparation of surfaces and applying 02 coats of interior emulsion paint over new surface (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer on existing yellow coloured surface complete all as specified and directed. Make of Interior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Interior Emulsion : Asian (tractor shyne) / Berger (bison) / Nerolac (BEAUTY sheen)
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161 1979 grade St.-240 complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed.
S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed.
S&F 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws as specified all as specified and as directed.
M&L for preparation newly or previously untreated steel surfaces of any description over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide complete all as directed.
Supply, install, testing and commissioning of Full automatic organic waste composting machine of capacity 300Kg/day using input of food waste.,garden waste, all type of organic waste having output of otganic Bio fertiliser made of SS-304 , High temp based Microbes supporting composting, including foundation complete all as specified & directed. Note :Contarctor should submitt SLD of plant, electrical network before instllation of plnat from GE .
Supply, install, testing and commissioning of Full automatic shredder machine of capacity 300Kg/day using input of food waste.,garden waste, all type of organic waste having output of 8-10mm output of input material, High temp based Microbes supporting composting complete including foundation all as specified & directed. Note:Contarctor should submitt SLD of plant, electrical network before instllation of plnat from GE.
Supply, install, testing and commissioning of Balling machine of capacity 15 Ton/hr using input of Compact & balling plastic waste such as bottles and plastic packets complete including foundation all as specified & directed. Note :Contarctor should submitt SLD of plant, electrical network before instllation of plnat from GE.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
M&L for point wiring with using 1.5 Sqmm (nominal area) with multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade , ISI -694 marked with valid CML No in and including medium grade, PVC concealed conduit of any thickness of dia not less than 20 mm and conduit accessories, ISI marked with valid CML no (IS-9537-19 for conduit and IS :3419:19765 for conduit accessories )concealed in wall with mild steel/ pressed steel modular sunken box (with earth dolly) of 1.6mm thick of suitable size, duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer externally covered with modular cover and plate for fixing of modular switch,socket etc including PVC insulated multi stranded copper conductor to commom earth and connecting to earth dolly complete all as specfied and dircted for the following:- NOTE :- 1. The complete wiring installation shall be carried out in accordance and conformity with IS 732:1989 "code of practise for electrical wiring(latest version). 2. The unit rate aganist item of PVC concealed conduit point wiring includes for MS pressed steel sunken box for modular wiring GI sunken box duly painted with two coats of anti corrosive paint/black bituminous paint externally and two coated of aluminium paint over a coat of red oxideprimer internally for fixing switches,regulator, socket outlet etc with modular plate & box ISIS marked. 3.All screws,fasteners ,bolts,nuts & washer etc shall be of cadmium plated, The cost of which deemed to be included in the unit rate. 4.The complete wiring installtions shall be tested on completion as specfied in particular specfications. 5.The cutting/leaving , forming chases shall be done with electric cutter. 6.Cutting chases in stone masonry wherever shall be deemed to be included in unit rate. 7.The completed wiring Quoted rate shall be deemed to include the making good the disturbed surface for concealed with CM 1:4 cement motor including finishing the surface to match with the existing surface. 8. Fittings like modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'.
One light/buzzer/fan point controlled by one; one way switch.
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch.
One 3 pin socket out let 5 amp point on the (same board) with other switches.
All as per item No. 30 here-in-before but with 2.5sq mm size FRLS single core pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor and 2.5sqmm PVC insulated and unsheathed cable 1100 volts grade with multistrand copper conductor as earth wire for 3 pin socket outlet 15 amp on independent board. (only one point per circuit)
Supply and fix ceiling rose surface bakelite , three terminals, 230V AC with polycarbonate body complete all as specified and directed.
Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix socket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix in repair modular fan regulator 120 W 2 module complete all as specified and directed.
Supply & fix earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per all as specified and directed.
Supply and fix lamp holder PVC / Polycarbonate type suitable for LED lamp fitting including LED 9watt bulb complete all as specified and directed.
Supply and fix in repair LED 20 W high quality indoor batten type tube light fitting with PC housing and as well light application , electrical connection of three core 0.5 sqmm copper flexible connection from ceiling rose to tube light fitting and with proper square box for fitting of tube light fitting complete all as specified and directed.
S & F sheet metal enclosure powder painted for MCB DB SPN 08 way double door with IP-42 protection with Din rail and busbar complete all as specified and directed.
Supplying and fixing sheet metal enclosure powder painted for MCB DB vertical type TPN 4 way double door with dinrail and busbar with IP-43 protection with door earthing and isolated neutral bar and insulated busbar assembly including MCCB of 100 Amps complete all as specified and directed.
Supply & Fixing MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
M/L for Sub main wiring with 4 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC concealed conduit in stone masonry/brick masonry including accessaries with 6sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: 2 runs of cable and one run earth wire and concealed PVC conduit will be measured as one length.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, (Earthed) grade cross sectional area 95 sqm 3 core in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces complete all as specified and as directed
Supply, laying and testing cable XLPE insulated, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium, 1100 volts grade (Earthed), of following size complete all as specified and directed.
(a) 3.5 care 70 Sqm
(b) 4 care 25 Sqm
V & L for cable jointing kit for 11 kV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core, 95 SQ MM, XLPE insulated, armoured aluminium conductor cable complete all as specified and directed.
Supply, installation, testing and commissioning of 11 KV 200 Amps triple pole gang operated air break switch having 12 Nos porcelain insulator with earthing switch rotating type for horizontal or vertical Dperation mechanically operated 3 rows type mounted on FRP insulators (including insulators) and steel frame with operating mechanism consisting of operating rod of 25mm bore medium grade GI pipe of suitable length to operated from ground level including locking arrengment with pad lock with three Nos of keys including 11 KV swing out expulsion fuses (drop out type) of 10 Amps complete all as specified and directed.
Supply, install, testing and commissioning lightening arrestor (station type) outdoor nominall discharge current 65 KA, 11 KV including clamps, nuts, bolts and washers and connecting to earth with 32x6 mm GI strip complete all as specified and as directed.
Supply, installation, testing and commisioning of step down transformer, outdoor type, HT 11 kV, 3-Phase, LT 0.433 kV, 50 Hz, 3-Phase, 4- Wire, oil-cooled, including of first fill of transformer oil of dielectric strength not less than 50 kV, electrolyte grade, copper wound in accordance with vectof group DYN 11 with neutral brought out on LV side complete with all standard fittings, all as specified and of capacity 63 KVA, Level -2 mounted on a suitable platform as per TD of HQ cE JZ with following technical features: (i) Rating: HV- 11 kV , LV- 433 V (ii) Winding connections- HV-Delta, LV-Star (iii) Insulation: Class 'H' (iv) Applicable Standards: IS: 1180 (PART-1 2014) (v) Terminations HV & LV cable box for easy connection. (vi) Duty: Distribution Transformer. [viii] Noise Level: Less than 69 dB at 1 m NOTES: [i] Contractor shall submit the technical drawing, constructional drawings, safety features drawing etc. for approval of accepting officer. [ii] The contractor shall intimate for factory inspection for routine tests as per IS & ANSIC 57.12.90 (latest revision) in the OEM factory in presence of representative nominated by the accepting officer before dispatch from factory, tests after installation shall also be carried by SEI for which GE will intimate through proper channel.
Supplying, install and errect in true vertical positionpressed concrete poles of 11.00 mtr long having Each 152mm x 152mm at top and 152mm x 260mm at bottom class 9 poles complete bolts, nuts & screws as specified type, painting and marking alternate white and black strip 30cm height, painting pole number, letters/figures by black paint complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of able/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any tupe of soil complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth and not exceeding 3.0m depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type 1, flat as per size 250mm x 150mm x 40mm for LT cable and laid dry in trenches over underground cables complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class HV, Type 1, flat as per size 300mm x 180mm x 40mm for LT cable and laid dry in trenches over underground cables complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
M&L for loose filling with graded stone aggregates (granite) 40 to 80 mm spread thickness 150 mm for outdoor transformer com fete all as specified and directed.
M&L for cross arms bracings, supports, clamps andback plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape of size as indicated complete all as specified and directed .
M&L Anti climbing device,spike type fabricated out of MS bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
M&L for sand cushioning in trenches for protection of HT under ground cable including watering and consolidation complete all as specified and directed.
Supply and laying 100 mm bore galvanized steel tubing, heavy grade, with all fittings laid in trenches / road / etc complete as all s ecified and directed.
M&L for danger notice plate of 1.6 mm thick MS sheet vitreous enameled white with letters figures written in English, Hindi and Tamil (and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts size 25X20 cm,for HT supply rade complete all as specified and directed.
M & L for cable route indicator shown "HT UG cables" painted in brown colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specified and directed.
Supply and fix All aluminium conductor having high strength to weight ratio for jumper of 2/4 pole structure complete all as specified and directed.
Supply and conncetion of new Pin type, porcelain, vitreous,brown insulator on pole or any structure including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 voltsgrade all as specfied and directed.
Supply and conncetion Disc type insulator, porcelain, vitreous145mm high and 255mm dia ball and socket type, white, brown or green Two-in-series' assembly for tension with tension clamps for conductors,working pressure 11000 volts grade including connection of existing OH HT line all as specfied and directed
Supply and lay 25 mm dia UPVC pipes of pressure rating 10kg/cm2 fixed complete to walls, ceilling or in floors etc complete with all fitting and as directed.
Supply and fix UPVC Ball Valve of dia 25 mm complete all as specefied and directed.
M&L for cutting of existing DI/CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fitting including necessory exvation and earthwork, dewatering etc, if any involed, complete all as specified and directed for 50/100 mm bore of pipes
Excavation in trenches in soft/loose soil, not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specified and directed.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
TENDER8253.pdf
Tender Documents • 0.57 MB
PS8253.pdf
Tender Documents • 0.89 MB
BOQ_847195.xls
BOQ • 0.40 MB
LISTOFMAKE.pdf
Tender Documents • 0.20 MB
8253UPL.pdf
PDF • 0.27 MB
Download all tender documents and submit your bid