| 1 | L1₹30.7 LAccepted-AOC T 1 GARDEN VIEW APARTMENT NEW BANKER COLONY MUNDRA ROAD BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC being lowest and reasonable bidder | |
| 2 | L2₹43.2 L+₹12.4 L (40.4%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L2 | Rejected-Finance not L1 |
Tender Value
₹34.8 L
EMD Value
₹69,600
Closing Date
4 Sept 2024, 6:00 pmClosed
AGE (I) (CG) Jakhau
CGRA Naliya Kutch Gujarat-370655
PROVN OF CAR PARKING SHED AND ADDITION AND ALTERATION FOR EXTENSION OF CGOM PORCH FOR VIP CAR PARKING AT CGRA NALIYA FOR ICGS JAKHAU
2024_MES_656122_2
8132/E8
Open Tender
Civil Works
Item Rate
180 days
Naliya
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) (CG) Jakhau
₹69,600
Yes
4 Oct 2024
2 Jul 2024
6 Sept 2024
2 Jul 2024
4 Sept 2024
9 Jul 2024
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cum in soft/ loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface, complete all as specified as directed.
M&L for cement concrete 1:2:4 type B2, using 40mm graded stone aggregate for embedding posts, complete all as specified and directed by Engr-in-Charge.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240,etc complete all as specified and directed.
S & F rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted,bolted or welded attachment, Fe 410-W (Gde-E-250) quality-A, etc
M&L for preparation of new steel surface over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete.
S & F Pre - painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F Pre - painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws as specified.
S&F mild steel hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/loose soil.
M&L for Hard core of gauge n.exc 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone or boulders.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc.
M & L for sand filling under floors or in foundations including spreading, levelling, watering and consolidation
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade, with grey cement and pigment complete all as specified and directed.
M&L for cement concrete Type C1 1:3:6 (20 mm graded aggregate) in edges of path, rounded or chamfered on edges etc
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
M&L for preparation of new or previously untreated brick, stone, concrete, asbestos cement or plaster surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of primer
Removing excavated material (soils) exc. 50m and n.exc 100m and depositing where directed at a level n exc. 1.5 m above the starting point
Dismantling of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended works
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Dismantling of paver block including sand cushioning.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in hard /dense soil complete all as specified and directed.
Removing excavated material (soils) exc 1.50 Km and n. exc 5 Km and depositing where directed
M&L for cement concrete 1:4:8 type D2, using 40mm graded stone aggregate in foundation, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for Hard core of gauge exc 63 mm but n.exc 100 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone or boulders.
M&L for 150 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc.
M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc.
M&L for screed bed or bedding layer of mortar in cement mortar 1:6, 15 mm thick for laying floor finishes.
Material & Labour for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, all as specified and directed by Engr-in-Charge. Note:- Serviceable Granite stone obtained from item Sl No 21.00 above shall be used
Material & Labour for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, all as specified and directed by Engr-in-Charge.
M & L for vitrified parking tiles 30cm x 30cm, 10 mm thick, set, jointed and pointed in neat cement slurry in floors, with grey cement and pigment complete all as specified and directed by Engr-in-Charge.
M & L for CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
M&L for CRS bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
M&L for CRS bars 5mm and above upto and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required, and binding with MS wire not less than 0.9mm dia complete all as specified and directed.
Use & waste of formwork to sides of concrete foundations, rough finished surfaces of flat concrete, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, etc complete all as specified and directed.
Use & waste of formwork to rough finished surfaces of concrete, sides of pillars, posts, struts, piers, columns and stanchions,etc circular in plan complete all as specified and directed.
Use & waste of formwork to rough finished surfaces of flat concrete,soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), etc complete all as specified and directed.
Use & waste of formwork to rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide.
Use & waste of formwork to rough finished surfaces of flat concrete, sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in Columns, pillars, piers, posts and struts etc complete all as specified and directed.
M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in beams, cantilevers, bressumers, lintels over 1.5 clear span etc complete all as all as specified and directed.
M&L for precast PCC block masonry type in CM 1:5:8 with soild block of any size and set in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for rendering 5mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth (without using extra lime or cement) complete all as specified and directed.
M&L for rendering 15mm thick (in two coats, 10mm 1st coat +5mm 2nd coat) to fair faces of brick or concrete wall surfaces in cement mortar 1:4 finished even and smooth (without using extra cement) including mixing only integral water proofing compound in second coat as per manufacturer's instruction. Note : a) Integral water proofing compound will be measured and paid separately.
Supply only integral waterproofing compound.
Material & Labour for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
M&L for rendering 10mm thick to fair faces of concrete in cement mortar 1:3 including mixing only integral water proofing compound as per manufacturer's instruction. Note : a) Integral water proofing compond will be measured and paid separately.
Removing of existing APP based polymeric membrane and cleaning of newly constructed slab and filling of cracks with crack filler and removal of debris off MD land.
Material and labour for providing and carry out waterproofing treatment to sound concrete surface of terrace of porch slab etc. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc, carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with plasticised expandive grout admixture, application of polymer modified vatta at floor wall junction, filling of annular space around rain water outlet using non shrink cementitious grout and final application of two coats of liquid applied single component pitch free polyurethane coating Nitoproof 600 PF to achieve 1.5 mm WFT followed by sprinkling of dry sand for mechanical bonding etc. complete including all tools and tackles as per manufacturer's specification.
Coating shall be having Elongation (ASTMD 412) - >400, %, Tensile Strength (ASTMD 412) - 1.9, N/mm2, Recovery from Elongation (ASTM D412) - 95%, Tear Resistance (ASTM D624) - 15 KN/m, Adhesion in peel Strength (ASTM C836) > 50N, Water vapour transmission @ 2.3 mm thickness of film - 0.6 g/ sqm/hr, Initial Hardness (Shore A, ASTM D2240) - 60, Chemical resistance - unaffected by mild acids and alkalis and waterborne salts.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, etc complete, as specified and directed.
M & L for 8 mm thick, Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately etc completed all as specified.
Cutting holes in false ceiling, area of holes, etc (measured net in sq.cm) exc 225 but n exc 400 sq. cm, Square or Circular cutting completed all as specified and directed by Engr-in-Charge.
M&L for preparation of new unplastered ceiling surfaces and applying two coats distemper oil emulsion over a chalk whiting preparatory to distempering over and including 1 mm thick wall care putty all as specified and directed
S&F Italian letters of height 450mm and 60mm thickness with LED dotted lights, fixed with SS screw on walls and providing polished plain acrylic sheet having thickness of 2mm over the letters all as directed by Engr-in-Charge.
S&F MES and Coast Guard computerised printed logo of 600mm height, width upto 527 mm and 60mm thickness with LED dotted lights, fixed with SS screw and providing polished plain acrylic sheet having thickness of 2mm over the logo all as directed by Engr-in-Charge.
S&F 110 mm dia PVC (SWR) waste and vent pipes, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F PVC (SWR) bends any radius, bore of pipe 110 mm complete all as specified and as directed.
M&L for 12mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required.
M & L for finishing with kutch texture on walls/ Column/ Beam match with existing shade, clay mixing with horsedung/ cowdung (Mud Lippan) over two or more protective coats of exterior acrylic emulsion paints applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm over pieces of mirror in square and diamand shape, paste on layer of kutch texture with the help of approved adhesive, using pigments of required shade all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed or surface conduit as required minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm PVC insulated but unsheathed multi stranded copper conductor FR cable as earth continuity wire including making good disturbed surface as per existing specification for one light point controlled by one way switch.
M&L for point wiring complete with 4.00 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cable 650/1100 Volts grade conforming to IS-694 drawn through PVC concealed conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified.
Supply and fix recess mounted decorative ultra slim square profile LED light 15 watt , energy efficient , efficiency is greater than 100 lm/watt , 6500K, , polycarbonate extruded body, including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector and making good of existing wall surface complete all as specified and directed by Engineer - in - Charge.
S&F LED batten integrated channel 20 watt with eye soft technology & glarefree diffuser , 50 Hz , 6500K , lumen efficiency greater than 100lm/watt , energy efficient driver, wall mounted complete including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector.
Supply & fix modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified & directed.
M&L for modular switch 1 way 16 A, 1 module including modular cover plate with frame complete all as specified & directed.
M&L for module switch 1 way 6 A, 1 module including modular cover plate with frame complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all as specified and as directed.
M&L for sub main wiring with two run of 4 sqmm single core, PVC insulated, unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through surface rigid PVC Conduit not less than 20 mm with all accessories and 4 sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity wire complete all as specified and directed. Note: Two runs of main cable, one run of earth wire and one run of PVC conduit will be measured as one unit for payment.
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 415 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
Supply and fixing of MCB SPN, 415 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Supply and fixing of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed.
Material and labour for earthing complete with galvanized earth plate electrode in 60 cm x 60 cmx 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meter below ground level with top edge of earth plate at depth not less than 1.5 mtr below ground level connecting to and including GI wire 4.00 mm dia mm by means of GI bolts, nuts, check nuts and washer light grade, 15 mm dia GI protection pipe and connected to equipment, GI pipe medium grade 20 mm dia for watering and including funnel wire mesh, RCC pit cover and PCC 1:3:6 type C-2 including Rocksalt, charcoal, excavation and earth work disposal of surplus soil shown as plate No 3 of SSR Part - I 2009 and all as specified complete. Note : - The unit rate quoted shall deemed to have included for GI protection pipe, GI earth wire up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete.
KALIKAY ENTERPRISES (BID ID -3072468)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .