Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹5.3 L+₹42,375 (8.70%)Rejected-Finance DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹5.7 L+₹82,310 (16.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹7.2 L
EMD Value
₹14,500
Closing Date
11 Jun 2024, 6:00 pmClosed
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER TENDER DOCUMENTS AND BOQ
2024_MES_653923_1
AGE(I)/SL/8577
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) SURYALANKA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) SURYALANKA
₹14,500
Yes
1 Jul 2024
14 May 2024
13 Jun 2024
14 May 2024
11 Jun 2024
28 May 2024
15 May 2024 - 23 May 2024
Amount
M&L for daily attending of the any type fan / sweep complaints, Taking down unserviceable ceiling fan/ Exhaust fan/ wall monted fan/ pedestal fan of any make and sweep, by disconnecting the electricical connections and dismantling the fan by dismantling its blades, fan rod etc.. and examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fan to any location and position after necessary repair works/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conducter from ceiling fan to ceiling rose etc.. complete all as specified and directed by Engr-in Charge. Note:- (i) The parts replaced will be measured by relevant item as supplied only.
Removing defective winding of any type / sweep of ceiling fan and rewinding with new super enameled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of any make and re-assembling testing complete including replacement of flexible copper wire from ceiling rose to ceiling fan, replacement of 6201/ 6202, 6203/6204 bearing shaft, bush, connector for holding of Capacitor complete all as directed and specified.
All as per Item No. 02 above but exhaust fan of size 300/ 380mm sweep .complete all as specified and as directed.
All as per Item No. 02 above but exhaust fan of size 400/ 450mm sweep. complete all as specified and as directed.
All as per Item No. 02 above but pedestal/ air circulator fan of size 400/ 450 mm sweep, includes repair of base, proper fixing of metallic Stand , swing of fan over etc complete all as specified and as directed. complete all as specified and as directed.
All as per Item No. 02 above but wall mounted fan of any Sweep includes repair of base, proper fixing of fan on wall with necessary arrangements , swing of fan over etc .complete all as specified and as directed.
Note for Serial Item No. 01 to 06 (a) Replacement of spare parts found unserviceable/ defective will be measured and paid separately under relevant item of BOQ as supply only. (b) The rate for fixing serviceable items and new replaced items are deemed to be included in unit rate quoted by tenderer for above item. (c) All retrived unserviceable item obtained from dismantling shall be given to the contractor under relevant item of 'Schedule of Credit'.
S&F in repair exhaust fan blade for 240/300/380 mm sweep including removing the old UNSV blade complete all as specified and as directed.
Supply only following spare parts of ceiling fan of 1200mm/ 1400mm sweep of different make required as per the makes of existing fans as required to make serviceable the fan complete all as specified and as directed.
Rubber bush for shackle with clamp, bolt, nut, washers and lock pin suitable for Ceiling fan 1200mm/ 1400mm sweep.
Ball bearing of size No. 6201/6202/ 6203 suitable for ceiling fan / exhaust fan complete all as specified and as directed. Make:- SKF/ NBC/NTN/ ZKL/ Koyo/ Tata/ RHP
S&F in replacement condenser of oil filled (capacitor) 3.15/ 2.5 MFD, 220 Volts, AC, 50 Hz as per IS : 1709 suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and as directed. Make:- Tibcon/Ducati/ Keltron/ Crompton / Bajaj / Concap/ ABB
S&F in replacement condenser 4 MFD, 220 Volts, AC, 50 Hz as per IS : 1709 suitable for exhaust fan 300/ 380/ 450 mm sweep complete all as specified and as directed. Make:- Tibcon/Ducati/ Keltron/ Crompton / Bajaj / Concap/ ABB
S&F in replacement Three core 0.5 sqmm flexible multi strandard copper wire for connecting ceiling fan/ exhaust fan/ wall fan to ceiling rose complete all as specified and as directed. Make: Polycab/ Finolex/ Anchor/ Havells/ Gloster
M&L for scraping of Ceiling / Exhaust fan to remove old paint and painting of ceiling fan with blade, down rod, etc of exiting colour (white/brown) with synthetic enamel paint complete all as specified and as directed.
S&F Fan Balde (Set of 3) suitable for ceiling fans of 1200 mm sweep of colour White/ brown and fixing to ceiling fan complete all as specified and as directed.
M&L for Servicing of geyser includes Cleaning of heating element with abrasive paper, Checking of Electric connections, Cleaning of Water tank etc complete all as specified and as directed.
M&L for repair/ replacement of heater element of 1.5 kw suitable for geyser of capacity 15 to 25 Ltr as per existing model complete all as specified and as directed.
M&L for repair/ replacement of Thermostat suitable for geyser of capacity 15 to 25 Ltr as per existing model complete all as specified and as directed.
M &L repair/ replacement of temperature setting knob complete all as specified and as directed.
S&F in replacement 20 mm dia galvanised or stove enameled screwed steel conduit of length n.exe than 1.2 mtr with back plate, check nuts, lock pin, etc for fixing the ceiling fan at high roof/ false ceiling complete all as specified and as directed.
S&F in replacement of modular Fan regulator electronic step type, 120W- 2 module, 240V single phase as per Required manufacturing company model in Ground complete all as specified and as directed.
S&F in replacement of stepped type electronic Fan regulator flush type , 120W 240V single phase as per required manufacturing company model in Ground complete all as specified and as directed.
S&F in replacements of hot water connection flexible pipe for connection to geyser to pipe complete all as specified and as directed.
M&L for checking Ceiling fan for its functioning and safety of hanging , Rubber bush, hook etc.. And replacing the same in case found damaged/ non function complete all as specified and as directed. Note (i) Contractor should maintain a register and get the signature of the residents after duly checked (ii) Spares replace will be measured and paid Separately
BEST ENGINEERING
DHANA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .