Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.1 LAccepted-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹28.0 L+₹1.9 L (7.35%)Rejected-Finance HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-2 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Oct 2024, 6:00 pmClosed
GE(AF) Naliya No. 1
GE AIR FORCE STATION NALIYA NO 01
REPAIR/MAINTENANCE OF STP PLANT INCLUDING MISC WORK AT AF STN NALIYA
2024_MES_673060_2
9001/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
Naliya
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(AF) Naliya No. 1
₹50,000
Yes
14 Jan 2025
30 Sept 2024
24 Oct 2024
30 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
Cleaning of tanks after desludging from sewage tanks (Stilling chamber, Bar & screen Chamber) at STP Plant of capacity 1.5 MLD shall be carried out with water and chemical as applicable and complete white wash from inside after cleaning the tanks and dates of cleaning shall be marked on tank etc complete all as specified and directed. Note:- (i) Rates for dewatering and desludging of tanks including T&P and safety equipments are included in above item. (ii) Cleaning of each tank will be measured and paid seperately.
Cleaning of tanks after desludging from sewage tanks (Equilisation Tank, Sedimentation Tank, MBBR Tanks, treated water tank, Chlorine Contact Tank, Sludge Holding Tank) at STP Plant of capacity 1.5 MLD shall be carried out with water and chemical as applicable and complete white wash from inside after cleaning the tanks and dates of cleaning shall be marked on tank etc complete all as specified and directed. Note:- (i) Rates for dewatering and desludging of tanks including T&P and safety equipments are included in above item. (ii) Cleaning of each tank will be measured and paid seperately. (iii) Safety of manpower involved will be of prime importance and contractor shall make arrangement s considering safety of manpower.
Material and labour for cleaning of main incoming sewage collection tank/booster tanks, including necessary T&P such as pump set for de-watering and cleaning upto bottom of the well by means of equipment with complete safety equipment and masks for the persons doing the job and lifting of sludge by means of Hydra and taking out all clay/mud/sludge/grit/stone pieces and other material deposited in the sewage well during course of time and removing deposited material to outside the premises of the station including necessary transportation for taking out from the site of the well complete all as specified and directed. Note :- No direct manpower to be introduced inside the sewage well as per the goverment norms.
Material and labour for carrying out the tests of treated water from NABL approved lab every month and maintain the record of treated sewage at each STP Plant as per frequency :- (i) PH Valve (ii) TSS (iii) BOD (iv) COD (v) Oil & Grease (vi) FC Min (vii) Nitrate CN Note:- (i) Test report for each month should be submiited at the end of month by contractor otherwise penalty of Rs. 2000/- per month will be imposed. (ii) Rate quoted shall deemed to be included for cost of sterilised bottle and to and from transportaion charges for collection samples upto Lab.
Supply only greasing for bearing of centrifugal Pumps all as specified and as directed.
Material and labour for repair & overhauling of 30 HP electrical induction motor, 3 phase, 415 volts including disconnecting all electrical connections, decoupling from pump, taking down the motor from foundation, cleaning and varnishing the stater & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections, checking the vibrations, RPM, DOR, testing on full load complete all as specified and directed.
Material and labour for repair & overhauling of 5 to 7.5 HP, 3 Phase monoblock pump set, taking out impeller, cleaning, descaling & greasing to bearings incl replacement of unserviceable parts such as bearings, gland flange, etc. Cleaning and varnishing the starter and rotar, winding, heating and drying replacement of burnt terminals of motor assembling in the pump with new packing materials nuts, bolts, washers checking alignment connecting all electrical/water connections,checking the vibrations & alignment, RPM,DOR, testing the pump sets of on full load, complete all as specified and directed:- Notes:- (i) Cost of small U/S parts such as new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes , coupling bolts shall deemed to be inclusive in quoted rate. (ii) Major unserviceable spares as listed below shall be measured and paid separately.
All as per serial item number 7.00 here-in-before but of capcity 0.5 to 1 HP, 3 Phase
Material and labour in repairs for rewinding of 30 HP , 3 Phase capacity induction motor by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size/turns, varnishing with class 'B' insulation, balancing of shaft, incl replacement of UNSV connection plate / terminal point as per site requirement, assembling the motor including transportation, testing as per the specified RPM at workshop complete all as specified and as directed.
All as per serial item number 9.00 here-in-before but of capcity 5HP-7.5 HP, 3 Phase
All as per serial item number 9.00 here-in-before but of capcity 0.5-1 HP, 3 Phase
Supply and fix in repair of the following parts for existing monoblock pump set electric driven 3 phase 415 volt 5 to 7.5 HP complete all as specified and directed:-
Motor bearing with housing
Motor cooling fan
Cover bolts & washers
CI impellar as per existing model complete
Gland packing
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Shaft seal of existing size
Motor connection plate with cover plate
Supply and fix in repair of the following parts for existing monoblock pump set electric driven 3 phase 415 volt 0.5 to 1 HP complete all as specified and directed :-
Motor bearing with housing .
Motor cooling fan
Cover bolts & washers
CI impellar as per existing model complete
Gland packing
SS Sleeve (Gland Sleeve)
Pump shaft with studs and nuts for pump body.
Shaft seal of existing size
Material and labour for lifting of submersible pump set of 40HP capacity carefully from open well/UG Sump/SWT alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of submersible cable aside for reuse and lowering into well/sump/SWT after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and as directed. Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc. (ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE's decision shall be final and binding in this regard.
Material and labour for complete opening of horizontal submersible motor 40 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed. Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of pump seal, replacement of wornout nut, bolts, washers etc complete. (iii) Winding shall be measured and paid separately.
Material and labour for rewinding the submersible motor of 40HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete all as specified and as directed.
Supply and fix in repair of following parts for existing submersible pump set electric driven 3 phase 415 volt 40 HP complete all as specified and directed
Pump bearing
Pump bush
SS sleeve
CI impellar as per existing model
Pump shaft
Shaft seal of existing size
Material and labour for Lifting of non-clog pump set of 10 HP to 15 HP capacity carefully from sewage well alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of cable aside for reuse and lowering into well after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and as directed. Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc. (ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE's decision shall be final and binding in this regard.
All as per serial item number 18.00 here-in-before but of capcity 3 to 5 HP
Material and labour for complete opening of non-clog pump motor 10 HP to 15 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed. Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of wornout nut, bolts, washers etc complete. (iii) Winding shall be measured and paid separately.
All as per serial item number 20.00 here-in-before but of capcity 3 to 5 HP
Material and labour for rewinding the non-clog motor of 10HP to 15 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete including replacement winding oil and oil seal complete all as specified and as directed.
All as per serial item number 22.00 here-in-before but of capcity 3 to 5 HP
Supply and fix in repairs of the following parts for existing nonclog pump set electric driven 3 phase 415 volt 10 HP to 15 HP complete all as specified and directed.
Pump bearing
Pump bush
SS sleeve
CI impellar as per existing model
Pump shaft
Shaft seal of existing size
Supply and fix in repairs of the following parts for existing submersible pump set electric driven 3 phase 415 volt 3 HP to 5 HP complete all as specified and directed:-
Pump bearing
Pump bush
SS sleeve
CI impellar as per existing model
Pump shaft
Shaft seal of existing size
Supply and fix in replacement of flat/V belt/coupling coupled with air blower motor or pump motor/sludge making motor set as per existing complete all as specified and directed.
Supply and fix in repairs PVC insulated 3 core 4 Sqmm copper multistranded PVC sheathed flexible cable suitable for Non clog motor ISI marked and conforming to IS : 694 and connecting to submersible pump with water proof jointing kit and to LT panel with lugs after taking out old unserviceable cable complete all as specified and directed.
Supply and fix in repairs PVC insulated 3 core 10 Sqmm copper multistranded PVC sheathed submersible flexible cable ISI marked and conforming to IS : 694 and connecting to submersible pump with water proof jointing kit and to LT panel with lugs after taking out old unserviceable cable complete all as specified and as directed.
Material and labour for taking out Non Return Valve of 80mm/100mm/125mm/150mm dia from open well including taking column pipe of any size and length, disconnecting of Non Return Valve from column pipe, reconnecting of Non Return Valve after servicing/repairing, lowering of Non Return Valve duly connecting the column pipe, replacement of worn out nut, bolts, washers etc complete all as specified and directed. Note : The quoted rate shall be inclusive of necessary T&P required for lifting and lowering of Non Return Valve from open well/neccessary drain out of water as required as per site requirement.
Supply, fixing, jointing and testing of 100mm/125mm Cast iron Non Return valve without by pass arrangement, Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out old unserviceable Non Return Valve complete all as specified and directed. Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) The quoted rate shall be inclusive of taking out GI/MS/HDPE pipe from open well, disconnecting of unserviceable Non Return Valve, replacement of unserviceable nut, bolts, washers etc, lowering of pipe duly assembleed the new Non Return Valve etc complete. (iii) The quoted rate shall be inclusive of T&P required for taking out column pipe of any capacity and size of any length from open well.
All as per serial Item number 30.00 here-in-before but 150 mm bore.
Supply and fix in repairs sluice valve class PN 1.6 heavy duty flanged end with MS spindle cast iron whel for operation conforming to IS-14846 of 2000 incl flanged joint on both side by using rubber gasket of size 100mm/125mm dia all as specified and directed.
Supply and fix in repairs butterfly valve, PN 1.6 conforming to IS 13095/BS EN 593 BS 5155) (wafer type) gear operated, SG Iron Construction, SG Iron Disc which is accurately guided between the two stems, integrally moulded rubber lining (EPDM/Nitrile/Neoprone) of size 80 mm (3”) dia.
All as per serial item number 33.00 above but 100 mm (4") bore.
All as per serial item number 33.00 above but 150 mm (6") bore.
All as per serial item number 33.00 above but 200 mm (8") bore.
Supply and fix in repair MCCB 3 pole , 415 volts , fixed thermal and fixed magnetic setting 63 Amps to 100 Amps with braking capacity 16 KA, Ics=100% Icu, complete including replacement of old unserviceable lugs, spreader connector complete all as specified and directed .
All as per serial item number 37.00 here-in-before but 125 Amps, with breaking capacity 16 KA.
Supply and fix in repair MCCB 4 pole , 415 volts , fixed thermal and fixed magnetic setting upto 160 Amps with braking capacity 16 KA Ics=100% Icu, complete including replacement of u/s lugs, spreader connector complete all as specified and directed.
All as per serial item number 39.00 here-in-before but 200 Amps, with braking capacity 35 KA.
All as per serial item number 39.00 here-in-before but 250 Amps, with braking capacity 35 KA.
All as per serial item number 39.00 here-in-before but 400 Amps, with braking capacity 35 KA.
Supply and fix in replacement of start push button of Green colour as per site requirement complete all as specified and directed.
Supply and fix in replacement of stop push button of Red colour as per site requirement complete all as specified and directed.
Supply and fix in replacement of motor ON indiating light of green colour as per site requirement complete all as specified and directed.
Supply and fix in replacement of motor Trip indiating light of yellow colour as per site requirement complete all as specified and directed.
Supply and fix in replacement of neon LED light of Red/Yellow/Blue colour as per site requirement complete all as specified and directed.
Supply and fix in repairs power contactor FP AC-1 duty with 240 VAC Coil of capacity 400 Amps (MCX 34) with add-on aux contacts 2 NO+2 NC -01 Nos incl with all necessary internal electrical connections and taking out old unserviceable power contactor all etc complete all as specified and directed.
Supply and fix in repairs power contactor TP AC-3 duty with 240 VAC Coil of capacity 50 Amps (MNX 50) incl with all necessary internal electrical connections and taking out old unserviceable power contactor complete all as specified and directed.
Supply and fix in repairs power contactor TP AC-3 duty with 240 VAC Coil of capacity 40 Amps (MNX 40) incl with all necessary internal electrical connections and taking out old unserviceable power contactor complete all as specified and directed.
Supply and fix in repairs power contactor TP AC-3 duty with 240 VAC Coil of capacity 32 Amps (MNX 32) with add-on blocks 1NO/1 NC -01 Nos incl with all necessary internal electrical connections and taking out old unserviceable power contactor complete all as specified and directed.
Supply and fix in repairs power contactor TP AC-3 duty with 240 VAC Coil of capacity 18 Amps (MNX 18) with add-on blocks 1NO/1 NC -01 Nos incl with all necessary internal electrical connections and taking out old unserviceable power contactor complete all as specified and directed.
Supply and fix in repairs power contactor TP AC-3 duty with 240 VAC Coil of capacity 12 Amps (MNX 12) with add-on blocks 1NO/1 NC -01 Nos incl with all necessary internal electrical connections and taking out old unserviceable power contactor complete all as specified and directed.
Supply and fix in repairs power contactor TP AC-3 duty with 240 VAC Coil of capacity 9 Amps (MNX 9) with add-on blocks 1NO/1 NC -01 Nos incl with all necessary internal electrical connections and taking out old unserviceable power contactor complete all as specified and directed.
Supply and fix in repairs auxiliary contact block MNX A2,1 No 1 NC including with all necessary internal electrical connections and taking out old unserviceable auxiliary contact complete all as specified and directed.
Supply and fix in repairs add-on auxiliary contact block 1 NO + 1 NC suitable for MNX / MCX type contactors including necssary internal electrical connections and taking out old unserviceable auxiliary contact complete all as specified and directed.
Supply and fix in repairs thermal overload relay of capacity 30-50 (MN-5) Amps with all necessary internal electrical connection and taking out old unserviceable thermal overload relay complete all as specified and directed.
Supply and fix in repairs thermal overload relay of capacity 9-15 (MN-2) Amps with all necessary internal electrical connection and taking out old unserviceable thermal overload relay complete all as specified and directed.
Supply and fix in repairs thermal overload relay of capacity 4.5-7.5 (MN-2) Amps with all necessary internal electrical connection and taking out old unserviceable thermal overload relay complete all as specified and directed
Supply and fix in repairs thermal overload relay of capacity 2-3.3 (MN-2) Amps with all necessary internal electrical connection and taking out old unserviceable thermal overload relay complete all as specified and directed.
Supply and fix in repairs Single Phasing Preventer Relay type VSP-II, 415V including necessary internal electric connection with size copper wire complete all as specified and directed.
Supply and fix in repairs electronic timer for star-delta time delay 30 to 120/3 to 30 seconds all as per existing sample complete including internal electric connection with suitable size copper wire all as specified and as directed.
Supply and fix in repair ammeter 415 volt, 3 phase digital type including necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and directed.
Supply and fix in repair voltmeter 415 volt,3 phase 0 to 500 volts rating, analog type including necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and directed.
Supply and fix in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and 6 Amps to 32 Amps current carrying capacity in the MCB DB/LT starter panel complete with connection testing and commissioning.
Supply and fix in repairs 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN and 16 Amps to 32 Amps current carrying capacity in the DB/LT starter panel complete with connection testing and commissioning complete all as specified and directed.
Supply and fix in replacement of terminal strip 6 way all etc complete including electrical connection complete all as specified and directed.
Supply and fix in replacement of terminal strip 3 way all etc complete including electrical connection all as specified complete all as specified and directed.
Material and labour for preparation of old painted surfaces of centrifugal pump set of 30 HP capacity and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
All as per serial item number 70.00 here-in-before but of capacity 5 to 7.5 HP
All as per serial item number 70.00 here-in-before but of capacity 0.5 to 1 HP
Material and labour for removing existing PCC foundation and providing new PCC foundation for installation of pump sets of 7.5 HP capacity on new base plate including high tension grouting bolts, complete all as specified and directed. Note:- Cost of new Base Plate shall be inclusive of quoted rate.
All as per serial item number 73.00 here-in-before but of capacity 5 HP monoblock pumpset.
Material and labour for installation of pumpset of following sizes on New PCC foundation and fixing with new bolts and nuts for base plate, fabricating to suction, delivery and priming line and connecting with existing lines, connecting power supply and testing, commissioning of pump set of 7.5 HP capacity, complete all as specified and directed.
All as per serial item number 75.00 here-in-before but of capacity 5 HP monoblock pumpset.
Labour only for attending of Electric compliants of existing STP panels /Sewage well LT starter Panels/CF Motors/Non-clog motors/Horizontal submesible, including connecting electrical accessories / spares of STP installation, electrical fitting & short circuits in panel/CF Motors/Submersible motors/ Panels complete all as directed by Engineer-in-charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item ) Notes :- (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician as applicable assisted with adequate No of helpers as directed by Enginner-in-charge. (ii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complaint. (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made. (iv) Any types of machinery/, T & P required for attending the complaints shall be provided by the contracor. The quoted rate shall be inclusive of replacement of burnt out lugs, refreshing of burnt out cable, reconnecting, meggering, fault locating etc complete. (v) The elecrician shall always be in possession of all Electrician tools, LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site.
Material and labour in repairs for earthing complete with copper earth plate electrode 60×60cm ×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip of 20x3.15mm (upto 7.5m in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including charcoal, rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel, 32mm dia light grade for protection of earth electrode, 20mm dia for watering complete all as specified and directed and tested on completion.
Supply and fixing in repairs of Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including jointing with rivets/brazing etc complete all as specified and directed.
Material and labour for repairs of mild steel structure with framed work such grills, gratings etc with ends of bars shouldered and/or rivetted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand made sliding bolts etc as conforming to Fe290, Gde E-165 including two coats of paints of approved colour and including one coat of red oxide primer complete all as specified and as directed.
Supply, laying and testing of 4 core x 25 Sqmm cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor with suitable size thimbling, laid in trench/floors/wall/ceiling complete all as specified and directed.
Supply, laying and testing of 2 core x 10 Sqmm cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor with suitable size thimbling, laid in trench/floors/wall/ceiling complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry aor laid dry and pointed complete all as specified and as directed
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Material and labour for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in sub-base finished even and fair complete all as specified and as directed.
Material and labour in repairs for factory made machine pressed precast concrete rubber moulded interlocking paver block and shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade fixed with grey cement and pigment complete all as specified and directed.
Excavation in post holes in soft/loose soil (or similar holes) each not exceeding 0.5 cum getting out, returning filling in and ramming earth to broken rubble mixed with earth around in layers not exceeding 25 cm, and removing surplus soil to a distance not exceeding 50 metre and making goood surface complete all as specified and directed.
Material and labour for plain cement concrete, 1:3:6, type C-2 ( using 40mm as in foundations, filling and mass concrete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all complete all as specified and directed.
Supply and fix in repairs of steel work in tubular works (round or square)/(angle including special shaped washer etc complete using ERW or induction buttt welded tubes as in verticle posts, trusses, purlins (beam, tee, angle, channel, flat, sections) including distance pieces, cleats etc confirming to IS-1161-1979 grade St-240 complete including taking out old unserviceable steel work complete all as specified and directed
Supply and fix mild steel screw bolts (machine made) length of bolt exceeding 22.5 cm and not exceeding 30 cm alongwith hexagonal or square heads at one end and screwe the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long and diameter of neck 11 to 15 mm complete including taking out old unserviceable steel screw, nut bolts etc complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Supply and fix in repairs of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fix with self tapping screws complete including taking down of old unserviceable GI sheet of any description and size complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description, over 10 cm width, girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour in repairs of gravels and sand from filter media vessels including painting of the vessel with synthetic enamel paint both inside and outside surface all etc complete and supply and lay the media as per description give below :- Bottom layer : Gravel of 20-40mm nominal size (Thickness of layer as per site requirement). Third layer : Gravel of 12-20mm nominal size. (Thickness of layer as per site requirement) Second layer : Gravel of 2-6mm nominal size. (Thickness of layer as per site requirement) Top layer : Silica sand (1-2mm size). (Thickness of layer as per site requirement)
Material and labour in repairs activated carbon (IV-900) from carbon filter, cleaning the vessels from inside, painting the vessel with bitumen paint all etccomplete and supply and set activated carbon suitable for treatment plant installed at STP as per site requirement.
Supply and lay in repairs of float suspended plastic carriers with large protected surface areas for the growth of bacteria and proper decompoistion of sludge in all two MBBR tanks complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, etc in soft / loose soil getting out and levelling of bottom surface to required level complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick soft / loose soil complete all as specified and directed.
Removing excavated material (Soils) from site to a distance not exceeding 50 Metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Taking up or down GI tubing of size 15mm bore and connections from trenches / wall / floor complete all as specified and directed.
All as per serial item number 101.00 here-in-before but of size 20mm bore.
All as per serial item number 101.00 here-in-before but of size 25mm bore.
All as per serial item number 101.00 here-in-before but of size 50mm bore.
All as per serial item number 101.00 here-in-before but of size 80mm bore.
Taking up GI/ Cast Iron /Ductile Iron water mains of size 100mm dia (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead complete all as specified and directed.
All as per serial item number 106.00 here-in-before but of size 150mm bore.
All as per serial item number 106.00 here-in-before but of size 200mm bore.
Supplying, Laying, jointing, testing and commmisioning of DI Pipe 100mm dia as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and as directed at site. Note : - Joints shall be measured and paid separetely.
All as per serial item number 109.00 here-in-before above but of size 150mm bore.
All as per serial item number 109.00 here-in-before above but of size 200mm bore.
Supply and laying GI pipe 100mm dia medium grade ISI marked including all fittings in old/new position including fittings as per site requirement as in walls/ceilling/trenches, complete all as specified and directed.
All as per serial item number 112.00 here-in-before but of size 150mm bore.
Material and labour for refixing/relaying of old CI/DI/GI pipe and connections in new or old position in trench/floor of size 100mm dia complete all as specified and directed.
All as per serial item number 114.00 above but of size 150mm bore.
All as per serial item number 114.00 above but of size 200mm bore.
Supply and fixing in repairs of rubber tyton ring/rubber gasket for 100mm dia CI/DI pipe complete all as specified and directed.
All as per serial item number 117.00 here-in-before but of size 150mm bore.
All as per serial item number 117.00 here-in-before but of size 200mm bore.
Material and labour in repairs of CI/DI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore confirming to IS: 9523 complete all as specified and directed.
All as per serial item number 120.00 here-in-before but 200mm to 300mm bore.
Supply and laying GI pipe of size 15mm bore, medium grade ISI marked including all fittings in old/new position as in walls and ceilling/trenches, complete all as specified and directed.
All as per serial item number 122.00 here-in-before but of size 20mm bore
All as per serial item number 122.00 here-in-before but of size 25mm bore
All as per serial item number 122.00 here-in-before but of size 50mm bore
All as per serial item number 122.00 here-in-before but of size 80mm bore
Supply and fix in repair PVC heavy duty sprinklers suitable for 25 mm dia pipe pop up type 360 degree & connected accessories all as per site requirement including taking out old unserviceable sprikler compelte all as specified and directed.
Supply and fix in repairs 15 mm bore bib tap standard of PTMT any colour high pressure screwed for male/ female treaded of size 15mm bore complete all as specified and directed.
Supply and in fix in repairs of UPVC pipe 15 mm bore, SCH 40 type with necessary fittings, all as required at site including taking down old unserviceable UPVC pipe complete all as specified and directed.
All as per serial item number 129.00 here-in-before but of size 20mm bore.
All as per serial item number 129.00 here-in-before but of size 25mm bore.
All as per serial item number 129.00 here-in-before but of size 50mm bore.
Supply and fix of UPVC ball valves of size 50mm dia complete as per requirement at site including taking out old unserviceable ball valves complete all as specified and directed.
All as per serial item number 133.00 here-in-before but of size 25mm bore.
All as per serial item number 133.00 here-in-before but of size 20mm bore.
Supply and topup in replacement suitable compressor oil in air blower at STP complete all as specified and as directed.
Supply only chemicals PAC (Sodium Hypo chlorite) required to achieve disired parameter of treated water for operation of the plant, at least one month requirement of the materials required shall be kept at site at a time complete all as specified and directed.
Supply only chemicals PE (Poly Electrolite) required to achieve disired parameter of treated water for operation of the plant, at least one month requirement of the materials required shall be kept at site at a time complete all as specified and directed.
Supply and fixing in repairs of Electro Magnetically Actuated Daphragm of flow rate 12 LPH, max pressure 12 Kg/Cm2g,, manual speed control adjustable while running or stopped, electronically operated mechancially actuated diaphragm, manual stroke length adjustable while running, electro mangnetc drive, accuracy +/- 2% of raed flow from 10% to 100% stroke, suction lift upto 1.5m water max complete all as specified and directed.
Supply and fix in repairs of flexible pipe of 40 mm bore complete all as specified and directed.
Supply and fix in repairs air blower pressure release valve 3" for root blower of capacity 760m3/hr, pressure rating upto 0.65 Kg/Cm2 for STP air blower application all etc complete all as specified and directed.
Supply and fix in repairs rotational moulded Poly-ethylene water storage tanks of 1000 ltrs capacity double layered with ISI marking embossed on it (cylindrical vertical with closed top) hoisted and fixed in position complete including taking out old unservieable tank complete all as specified and as directed.
Supply only 15mm bore gun metal gate valves/Check Nut valves with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 complete including taking out old unservicable valves complete all as specified and directed.
All as per serial item number 143.00 here-in-before but of size 20 mm bore
All as per serial item number 143.00 here-in-before but of size 25 mm bore
All as per serial item number 143.00 here-in-before but of size 50 mm bore
Supply and fix in repair Solar Street Light luminaire wattage 50 W, >100 lumen/watt including suitable tubular pole of 5 m height mounted with inbuilt battery (LiFEP04) 12.8 V, 24 Ah, having 50 W Mono Crystalline SPV panel auto on / off of lights while dusk to dawn, complete including taking down old unservicable solar street light complete all as specified and directed.
Material and labour synthetic mat (rubber matting) suitable for 1100 Volts electrical grade 2m x 1m x 2mm thick chequered top, ISI marked to be laid in front of LT panel board, complete all as specified and directed.
Complete removal of the wild grass/ vegetation from surrounding area of STP installations area and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 Metre away from the site complete all as specified and directed Note:- (i) T&P machinary will be provided by the contractor. (ii) Cleaning should be done as directed by Engr-in-Charge.
Supply and fix in replacement street light on pole with LED Street Light Luminaries 35 watt fitting New Generation,having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V complete including taking out old unserviceable street light complete all as specified and directed.
Material and labour for removing old paint from surface of LT panel by scraping,rubbing and making good surface for painting and applying powder coated spary painting with existing colour complete as specified and directed.
Scraping old existing paint from pipes of different sizes including making smooth surface and primer and applying two coat of synthetic enamel paint of existing/approved colour complete all as specified and directed.
Supply and fix in replacement warm type LED 12W bollard Gate Light Lamp complete including taking out old unserviceable gate light lamp complete all as specified and directed
Labour only for excavation muddy soil from pipe line leaked area upto desired depth including fixing clamp/collar joint/Lead Joint /new pipe/fittings of required type and size of pipe line, and stopping of leakage and checking of any leakage and returning filling of soil for 80 mm bore CI/DI pipe line complete all as specified and directed.
All as per serial item number 154.00 here-in-before but for 100 mm bore CI/DI Pipe.
All as per serial item number 154.00 here-in-before but for 150 mm bore CI/DI Pipe.
All as per serial item number 154.00 here-in-before but for 200 mm bore CI/DI Pipe.
Supply only CI/DI mechanical collar Joint suitable for 200 mm bore CI/DI pipe line complete all as specified and as directed.
All as per serial item number 158.00 here-in-before but for 150 mm bore CI/DI Pipe.
All as per serial item number 158.00 here-in-before but for 100 mm bore CI/DI Pipe.
All as per serial item number 158.00 here-in-before but for 80 mm bore CI/DI Pipe.
GEE CEE ENTERPRISES (BID ID -3144695)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .