Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹11.6 L
EMD Value
₹23,145
Closing Date
8 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Preservation of Mata Shaiputhri Asthapan Temple Khanpora Baramulla B.W.O Electric work
2025_PWDJK_296210_1
NIT No.202/2025-26 Dt/24/11/2025
Open Tender
Electrical Works
Percentage
Khanpora Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹23,145
24 Nov 2025
24 Nov 2025
9 Dec 2025
24 Nov 2025
8 Dec 2025
24 Nov 2025
Wiring for light point / exhaust fan point/ceiling fan point with (P+N) 2X1.5 sq.mm FRLS-H (Havells/Finolex/Anchor /eqt make as approved by site engineer),PVC insulated copper conductor single core cable in surface / recessed Conduits (Anchor/ polycab/ Ravindra/ equivalent make as approved by site engineer) , with 6Amp .modular switch (Anchor roma urban /legrand/ SSK NV/equivalent make as approved by site engineer), modular plate, cover in front and suitable GI box (Excld. G.I Box laid ) etc of approved quality and make ISO/IEC Certified (quality of wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) job including cost of Circuit Wire in 1.5Sqmm Multi strand Copper wire from Switch board to D.B complete. inculading of Conduits .
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK Legrand/schnider/ ABB/ equivalent make as directed by engineer incharge.
Wiring for 6Amp Plug with(P+N+E) 3 x 2.5 sq.mm FRLS PVC ,Havells/Finolex/Anchor /eqt make as approved by site ) Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit complete including Conduits.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H Polycab /Havells/ Finolex/ Anchor/ eqt make as approved by site engineer)PVCInsulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Anchor/ polycab/ Ravindra/equivalent make as approved by site engineer) suitable GI box etc as required .
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/ Recessed medium class PVC conduit as required. (wire shall be approved before execution of wok by SITE In-charge Engineer strictly .
2X 10sq. MM+ 1 X 10 sq. MM (Phase +N+E) Power point Sub main in One runFrom Main Panel to .Distribution boards(Havells/Finolex/Anchor/eqt make )
2 X 6SQ.MM + 1 X 6. SQ.MM [Phase +N+E) For Lighting Sub main in one run and X-Ray supply from Main Panel to Distribution board(Havells/Finolex/ Anchor/eqt make)
Supply installation,testing and commissioning of Hylum make bakalite sheets of approved quality ISI specification fixed with secrews of required sizes at existing inspection boxes complete job.
Supplying and fixing of 6 to 32Amp Rating ,single pole, *C* Curve MCB Miniature Circuit Breaker Legrand /Havells or L&T / Schneider/ABB/siemens/ eq. make
Supply,Installation,Testing and Commissioning of 18/20 watt slim tube light having 6500K with manimum @ L 70 system luman out put complte of 18/20 watt cool led tube of Havells/Philips/Wipro/ jaquar /Eq. make .
Supply installation ,testing and commissioning of following rating, Double pole, (P +N) 240 V, C* Curve MCB of Legrand/ Havells//L&T/Schiendar /ABB/Eq. make.
32 Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/ eq. make
40Amp. Legrand /Havells or L&T /Schneider/ABB/Siemens/ eq. make
63Amp. Legrand /Havells or L&T /Schneider/ABB/ Siemens/ eq. make
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK/ eq. make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator. 8 Way Double door.
6 way, Double door
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required /8No.copper bear wire in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
Supply installation testing and commissioning of 18 W + LED Surface/conceeled Mounted Panel light luminary fitting round shape with minimum system lumen efficency of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India authorised lab . The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips / Havel's / Wipro or Jaguar / eq. make.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan decorative with 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/ Anchor / eq. make.
Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. Compt 400-450mm heavy duty of Usha/Polycab/Anchor/eq. make
Supply,and fixing of 2x2.5 sq.mm pvc insulated multristand FRLSH copper wire of approved Havells/Polycab/Finolex/Anchor/ eq. make as circuit wire for invertar supply laid on pvc conduit from switch board to DB complete job'
Supply, laying, Connecting and Commissioning of 70 sq mm 3.5 core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havel’s /with required size of thimbles dully crimped with hydraulic crimping tool including p/ fixing of saddles /clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories forProtection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench
Supply, installation, testing& Commissioning of IP-66 Protected high power 100 Watt LED Flood lights system with single piece preassur diecast Almunium with suitable lenses on LED toachieve various beam angles oh high power LED of 3 to 5 Watt having efficiency more then 85% and in compliance to BIS certified and trade mark with Electrical connector Surge power factor aof Havells/Crompton/ Philips/eq. make the light approved by site Engineer before installation.(Including cost of GI Bracket with arm 1.5feet 38mm dia)
Supply, Laying, testing and commissioning of 9 watt LED conceeled round type with minimum system luman effency of 100 ml with preasur die cost Almunium heat shrink cct 5700k,CRI 80.The LED with usefull life of 50000 Hrs at L 70.The input voltage shall be 150 v to 270v LM79 &LM 80 test report should be from Govt.approved in house NABL lab Govt.of India and two year waranty from date of completion of Philips/Havells/Wipro/Jaguar/eq. make.
Supply, Laying, testing and commissioning of 25/ 32 mm dia. High class PVC Unbreakable conduits to be laid in first floor ceeling and walls as sub-main pipes and downs in walls including cutting the wall and making good the same with 1:6 mix cement plaster in case of recessed conduit as required etc including cost of accessories like bends and ‘heavy Gauge Sheet Steel Deep Junction boxes of approved make .(Before laying of conduit the same to be approved by site Engineer) . Preferred make: Ravindera /Anchor/Alba/Polycab/ eq. make for sub main and main.
Supply installation testing and commissioning of 15/16 amp madular socket out let and 15/16 amp madular switch with modular plate and cover plate in box recessed in walla/ complete with refacing of walls sand and cement of existing holes as per ratio1;2;4 ISO/IEC certified of Havells/ Legrand/ Anchor / Schneidar/ L&T/ABB/ eq. make shall be approved before execution of work.
Supply installation testing and commissioning of 6 pin5/6 amp modular 2No.Socket out let and modular 2No.switch with madular plate and madular cover in frunt with box recessed in walls complete with refacing of walls with sand and cement of existing holes as per ratio of 1;2;4. ISO/IFC certified of Havells/ Legrand /Anchor/Schniedar /L&T /ABB/ eq. make shall be approved befor execution of work.
Supply and fixing of 6 amp/250 V A.C celling rose witg adiqute length 0.75 sq.mm pvc multristand copper wire of approved quality FRLSH for connection of exhaust and ceillin fans of First floor of building complete job.
Supply,installation and fixing of sinewave inverter capacity 10KVA rated power 8400 Watt with 24 months warranty safe for sensitive appliance with sinewave output inverter should run heavy loads like AC,geyser,photocopies,autooverload handling capacity installation and maintanence friendly offers high quality power backup solution for office and homes,MCB for protection from input mains,bypass switch fortsupplying output directly from grid,fault operation with the help of low harmonic distortion displaytive easily understand status of main ,deep discharge,etc,battery charging control system technolgy(ABCC) ensure faster battery charging,battery life around 70 percent of luminous/Microtech/Exide/ eq. make to be approved by EIC . complete job avalibility
Supply,installation,testing and commissioning of inverter battery 180AH/12V Exide invatuballar/luminous/microtech/eq make to be approved by EIC with its trollies.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.92 MB
BOQ_959524.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .