Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC Technically qualified L1 party | |
| 2 | L2₹12.9 L+₹1.1 L (9.41%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹14.0 L+₹2.2 L (18.5%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
₹10.7 L
EMD Value
₹26,635
Closing Date
20 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HOU (TP/TSP)
TP UNIT KMML CHAVARA
REMEDIATION OF TEST PATCH AREA ( FOR 1 R-UNIT) INSIDE KMML AS PART OF REMEDIATION OF CONTAMINATED LAND IN AND AROUND KMML
2024_KMML_664889_1
TP/TS/ENV/REMEDIATION OF TEST PATCH AREA/2024
Open Tender
Miscellaneous Services
Supply and Service
60 days
TP UNIT KMML CHAVARA
AS PER TENDER DOCUMENT
4 documents required · 4 mandatory
₹1,886
₹26,635
TP UNIT KMML CHAVARA
27 Apr 2024
29 Feb 2024
22 Mar 2024
29 Feb 2024
20 Mar 2024
29 Feb 2024
6 Mar 2024
Amount
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, with in premises of KMML with in a lead of 1km and lift up to 1.5m in all kinds of soil
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil, back filling and disposal of surplus excavated soil as directed, within a lead of 50 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work riveted, bolted or welded in built up sections, tubular sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete and painting with 2 coats of synthetic enamel of approved shade.
Boring / drilling bore well of required diameter for 200mm nominal diameter casing pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart / bore log, including hire & running charges of all equipment, tools, plants & machineries required for the job, all complete as per direction of Engineer in-charge, up to a maximum of 6m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC shallow well casing (CS) pipe of 200mm nominal diameter conforming to IS: 12818, having slotted holes including required hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer in-charge and removal of the same from the bore as per the directions of engineer in charge
Providing and fixing Polyvinyl Chloride (PVC) pipes of 50mm diameter to withstand pressure of 6k/cm2 for water supply, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps or other suitable arrangements at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in-charge.
Providing and fixing Polyvinyl Chloride (PVC) pipes of 32mm diameter to withstand pressure of 6k/cm2 for water supply, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps or other suitable arrangements at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in-charge.
Providing and placing at all floor levels polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing 32mm diameter Polytubes (Class II Polyethylene pipes as per IS 12786) to withstand pressure of 4k/cm2 for water supply, with perforations or openings for fixing sprinklers or drippers including all fittings as required to close the ends and connect them to 50mm diameter PVC lines as per direction of Engineer in-Charge.
Providing and fixing 25mm diameter Polytubes (Class II Polyethylene pipes as per IS 12786) to withstand pressure of 4k/cm2 for water supply, with perforations or openings for fixing sprinklers or drippers including all fittings as required to close the ends and connect them to 32mm / 20mm diameter Polytubes as per direction of Engineer in-Charge.
Providing and fixing 20mm diameter Polytubes (Class II Polyethylene pipes as per IS 12786) to withstand pressure of 4k/cm2 for water supply, with perforations or openings for fixing sprinklers or drippers including all fittings as required to close the ends and connect them to 25mm diameter polytubes as per direction of Engineer in-Charge.
Providing and fixing micro-sprinklers of polyethylene make with adapter having a discharge rate not less than 100 litres per hour, to the polytubes of different sizes (20mm / 25mm / 32mm), including making holes in pipes as required, connecting nipples and other fixtures as required etc. complete
Supplying and fixing water flow meter, industrial grade in PVC pipe for flow measurements in flushing pipes and leachate pipes.
Supplying and fixing digital portable pH monitoring instrument into PVC pipes for taking online measurements of pH in flushing solution and leachate solution
Supplying and fixing PVC ball valves in 50mm NB diameter PVC pipes
Providing and fixing PVC non- return valve of approved quality and of required diameter on leachate pipe
Supplying and fixing PVC Foot valve of required diameter in bore intake pipe
Remediation work in test patch area as follows:a) Preparation of lime solution in the specified concentration as per directions of Engineer in-charge.b)Adding the slaked lime to water in the tanks and mixing them thoroughly with a mechanical mixer as per directions of Engineer in-charge.c)Releasing the alkaline solution to ground through pipe network / polytubes by pumping as per directions of Engineer in-charge.d)Maintaining records of the measurements as per directions of Engineer in-charge. Measurement for this item shall be on the amount of alkaline solution pumped into land as measured in water flow meter.
Leachate Recovery work as follows: a)Pumping of leachate from borewell to Leachate Collection Tanker as per directions of Engineer in-charge.b)Transportation of Collected leachate in Tankers to ETP unit of KMML and pumping them to tanks / sumps as directed by the Engineer in-charge.c)Maintaining records of the measurements as per directions of Engineer in-charge.Measurement for this item shall be on the amount of leachate pumped into collection tank as measured in water flow meter
Dismantling the pipes laid and other items supplied to the work location carefully and relocating them into storage locations as directed by Engineer in-charge, Restoration of changes made to land, closing of bore wells by filling it with sand or closing the same with caps or plugs, backfilling all excavations etc. as directed by Engineer in-charge, work including all costs for labour, materials, transportation cost etc.
ANUKUMAR R
M ABDULSHUKKOOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .